Volumetric Modulated Arc Therapy Planning for Craniospinal Irradiation With a New O-ring Linac

被引:0
|
作者
Matsumoto, Kenji [1 ]
Monzen, Hajime [2 ]
Kubo, Kazuki [2 ]
Otsuka, Masakazu [1 ]
Nambu, Hidekazu [1 ]
Nishimura, Yasumasa [3 ]
机构
[1] Kindai Univ Hosp, Dept Radiol Serv, Osakasayama, Japan
[2] Kindai Univ, Grad Sch Med Sci, Dept Med Phys, Osaka, Japan
[3] Kindai Univ, Fac Med, Osakasayama, Japan
关键词
auto-feathering; halcyon; rapidarc; csi; supine craniospinal irradiation; RADIOTHERAPY; IMRT;
D O I
10.7759/cureus.36493
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study aims to determine the feasibility of using a new O-ring linear accelerator (Halcyon, Varian Medical Systems, CA, USA) to perform treatment planning using volumetric modulated arc therapy (VMAT) for craniospinal irradiation (CSI).A 20-year-old male patient with leukemia was selected. The planning target volume (PTV) was contoured to include the entire contents of the brain and spinal canal. The PTV margin was 10 mm applied to the clinical target volume (CTV). VMAT (RapidArc, Varian Medical Systems, CA, USA) planning was performed using four isocenter with five arcs, two full rotation arcs to cover the brain and upper part of the spinal cord, and one full rotation arc for the lower part of the spinal cord. The plan was created using the auto-feathering photon optimizer calculation of the planning system. The conformity index (CI) and heterogeneity index (HI) as well as dose-volume histograms of organs at risk (OAR) were evaluated. The patient position of +/- 3.0 mm in the craniocaudal direction was moved in to simulate the effect of treatment inaccuracy. The total treatment time was also measured.The CI and HI were 1.09 and 8.44, respectively. The mean dose (PTV) was 105.5%, and the mean dose (OARs) was lower than the planning dose constraints. Simulations with a patient position shift of +/- 3.0 mm resulted in an error of less than +/- 10.0% of the planned dose to the spinal cord. The total treatment time was within 15 minutes.VMAT planning for CSI with Halcyon achieved high conformality, uniform dose distribution, low dose to the surrounding normal tissues, and reduced treatment time.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] LINAC-BASED VOLUMETRIC MODULATED ARC THERAPY CRANIOSPINAL IRRADIATION
    Fukada, Junichi
    [J]. PEDIATRIC BLOOD & CANCER, 2022, 69
  • [2] Volumetric modulated arc therapy planning method for supine craniospinal irradiation
    Chen, Jianzhou
    Chen, Chuangzhen
    Atwood, Todd F.
    Gibbs, Iris C.
    Soltys, Scott G.
    Fasola, Carolina
    Xing, Lei
    [J]. JOURNAL OF RADIATION ONCOLOGY, 2012, 1 (03) : 291 - 297
  • [3] A new technique for robust volumetric modulated arc therapy treatment planning of craniospinal irradiation
    Chamberlain, Madalyne
    Klock, Stephan
    Linsenmeier, Claudia
    di Martino, Mattia
    Guckenberger, Matthias
    Tanadini-Lang, Stephanie
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2019, 195 (06) : 602 - 602
  • [4] Automating the Treatment Planning Process for Volumetric Modulated Arc Therapy Craniospinal Irradiation
    Romero, Ignacio O.
    Simiele, Eric A.
    Lozko, Yuliia
    Severyn, Yuliia
    Skinner, Lawrie B.
    Yang, Yong
    Wang, Jen-Yeu
    Xing, Lei
    Gibbs, Iris
    Hiniker, Susan M.
    Kovalchuk, Nataliya
    [J]. PRACTICAL RADIATION ONCOLOGY, 2024, 14 (02) : e165 - e172
  • [5] Treatment Planning Evaluation of Volumetric Modulated Arc Therapy (VMAT) for Craniospinal Irradiation (CSI)
    Fathy, S.
    Alalawi, T.
    Al-Dhaibani, N.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E658 - E658
  • [6] Craniospinal Irradiation: A Dosimetric Comparison Between O-Ring Linac and Conventional C-arm Linac
    Stroubinis, Theodoros
    Psarras, Michalis
    Zygogianni, Anna
    Protopapa, Maria
    Kouloulias, Vassilis
    Platoni, Kalliopi
    [J]. ADVANCES IN RADIATION ONCOLOGY, 2023, 8 (02)
  • [7] Assessment of a conventional volumetric-modulated arc therapy knowledge-based planning model applied to the new Halcyon© O-ring linac in locoregional breast cancer radiotherapy
    Costa, Emilie
    Richir, Thomas
    Robilliard, Magalie
    Bragard, Christel
    Logerot, Christelle
    Kirova, Youlia
    Fourquet, Alain
    De Marzi, Ludovic
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 86 : 32 - 43
  • [8] Acute toxicities after volumetric modulated arc therapy for craniospinal irradiation in adults
    Bronk, Julianna K.
    Myers, Pamela A.
    Tran, Danny
    Bryan, Jason
    Wagner, Timothy D.
    Bonnen, Mark D.
    Ludwig, Michelle S.
    [J]. JOURNAL OF RADIATION ONCOLOGY, 2018, 7 (04) : 317 - 323
  • [9] Quality Assurance of Multiple Isocentric Volumetric Modulated Arc Therapy for Craniospinal Irradiation
    Zhang, J.
    Lee, B.
    Lien, W.
    Han, J.
    Kim, D.
    Goldman, K.
    Lu, S.
    Hong, G.
    Lee, S.
    Rahimian, J.
    Qian, Y.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E609 - E609
  • [10] Improving Craniospinal Irradiation Technique Using Volumetric Modulated Arc Therapy (VMAT) Planning and Its Dosimetric Verification
    Yang, X.
    Tejani, M.
    Jiang, X.
    Elder, E.
    Dhabaan, A.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3565 - 3565