Automatic planning of the lower extremities for total marrow irradiation using volumetric modulated arc therapy

被引:8
|
作者
Lambri, Nicola [1 ,2 ]
Dei, Damiano [1 ,2 ]
Hernandez, Victor [3 ]
Castiglioni, Isabella [4 ]
Clerici, Elena [2 ]
Crespi, Leonardo [5 ,6 ]
De Philippis, Chiara [7 ]
Loiacono, Daniele [5 ]
Navarria, Pierina [2 ]
Reggiori, Giacomo [1 ,2 ]
Rusconi, Roberto [1 ,2 ]
Tomatis, Stefano [2 ]
Bramanti, Stefania [7 ]
Scorsetti, Marta [1 ,2 ]
Mancosu, Pietro [2 ]
机构
[1] Humanitas Univ, Dept Biomed Sci, Via Rita Levi Montalcini 4, I-20072 Milan, Italy
[2] IRCCS Humanitas Res Hosp, Radiotherapy & Radiosurg Dept, Via Manzoni 56, I-20089 Milan, Italy
[3] Hosp Univ St Joan de Reus, IISPV, Dept Med Phys, Tarragona, Spain
[4] Univ Milano Bicocca, Dept Phys G Occhialini, Piazza Sci 2, I-20126 Milan, Italy
[5] Politecn Milan, Dipartimento Elettron Informaz & Bioingn, Milan, Italy
[6] Ctr Hlth Data Sci, Human Techopole, Milan, Italy
[7] IRCCS Humanitas Res Hosp, Bone Marrow Transplantat Unit, Milan, Rozzano, Italy
关键词
Radiotherapy; Automation; TMI; VMAT; Field junction; TOTAL-BODY IRRADIATION; GUIDED TOTAL-MARROW; HELICAL TOMOTHERAPY; RANDOMIZED-TRIAL; LEUKEMIA; FEASIBILITY; BUSULFAN;
D O I
10.1007/s00066-022-02014-0
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose Total marrow (and lymphoid) irradiation (TMI-TMLI) is limited by the couch travel range of modern linacs, which forces the treatment delivery to be split into two plans with opposite orientations: a head-first supine upper-body plan, and a feet-first supine lower extremities plan. A specific field junction is thus needed to obtain adequate target coverage in the overlap region of the two plans. In this study, an automatic procedure was developed for field junction creation and lower extremities plan optimization. Methods Ten patients treated with TMI-TMLI at our institution were selected retrospectively. The planning of the lower extremities was performed automatically. Target volume parameters (CTV_J-V-98% > 98%) at the junction region and several dose statistics (D-98%, D-mean, and D-2%) were compared between automatic and manual plans. The modulation complexity score (MCS) was used to assess plan complexity. Results The automatic procedure required 60-90 min, depending on the case. All automatic plans achieved clinically acceptable dosimetric results (CTV_J-V-98% > 98%), with significant differences found at the junction region, where D-mean and D-2% increased on average by 2.4% (p < 0.03) and 3.0% (p < 0.02), respectively. Similar plan complexity was observed (median MCS = 0.12). Since March 2022, the automatic procedure has been introduced in our clinic, reducing the TMI-TMLI simulation-to-delivery schedule by 2 days. Conclusion The developed procedure allowed treatment planning of TMI-TMLI to be streamlined, increasing efficiency and standardization, preventing human errors, while maintaining the dosimetric plan quality and complexity of manual plans. Automated strategies can simplify the future adoption and clinical implementation of TMI-TMLI treatments in new centers.
引用
收藏
页码:412 / 419
页数:8
相关论文
共 50 条
  • [1] Automatic planning of the lower extremities for total marrow irradiation using volumetric modulated arc therapy
    Nicola Lambri
    Damiano Dei
    Victor Hernandez
    Isabella Castiglioni
    Elena Clerici
    Leonardo Crespi
    Chiara De Philippis
    Daniele Loiacono
    Pierina Navarria
    Giacomo Reggiori
    Roberto Rusconi
    Stefano Tomatis
    Stefania Bramanti
    Marta Scorsetti
    Pietro Mancosu
    [J]. Strahlentherapie und Onkologie, 2023, 199 : 412 - 419
  • [2] Total Marrow Irradiation and Total Marrow and Lymphoid Irradiation with Volumetric Modulated Arc Therapy
    Liang, Y.
    Kim, G.
    Ning, X.
    White, G.
    Mell, L.
    Pawlicki, T.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S200 - S200
  • [3] Total marrow irradiation for hematopoietic malignancies using volumetric modulated arc therapy: A review of treatment planning studies
    Mancosu, Pietro
    Cozzi, Luca
    Muren, Ludvig Paul
    [J]. PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2019, 11 : 47 - 53
  • [4] PRECLINICAL ASSESSMENT OF VOLUMETRIC MODULATED ARC THERAPY FOR TOTAL MARROW IRRADIATION
    Fogliata, Antonella
    Cozzi, Luca
    Clivio, Alessandro
    Ibatici, Adalberto
    Mancosu, Pietro
    Navarria, Piera
    Nicolini, Giorgia
    Santoro, Armando
    Vanetti, Eugenio
    Scorsetti, Marta
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (02): : 628 - 636
  • [5] The Evaluation of Total Marrow Irradiation Volumetric Modulated Arc Therapy Treatment Planning Using the Millennium and High Definition MLC
    Zuro, D.
    Vidal, G.
    Henson, C.
    Han, C.
    Hui, S.
    Ahmad, S.
    Ali, I.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E119 - E119
  • [6] Developing An Automatic Planning System for Total Body Irradiation (TBI) Treatment Using Volumetric Modulated Arc Therapy (VMAT)
    Tan, J.
    Chiu, T.
    Yan, Y.
    Lin, M.
    Lee, P.
    Jiang, S.
    Gu, X.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E546 - E546
  • [7] Total Marrow Irradiation: A Clinical Evaluation of a Volumetric Modulated Arc Therapy Technique
    Cozzi, L.
    Mancosu, P.
    Navarria, P.
    Nicolini, G.
    Vanetti, E.
    Clivio, A.
    Fogliata, A.
    Ibatici, A.
    Santoro, A.
    Scorsetti, M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S93 - S93
  • [8] Dosimetric study of volumetric modulated arc therapy fields for total marrow irradiation
    Han, Chunhui
    Schultheisss, Timothy E.
    Wong, Jeffrey Y. C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2012, 102 (02) : 315 - 320
  • [9] Volumetric Modulated Arc Therapy Based Total Marrow Irradiation and Dosimetry Verification
    Liang, Y.
    Mell, L.
    Kim, G.
    [J]. MEDICAL PHYSICS, 2011, 38 (06) : 3806 - +
  • [10] Dose planning of a total body irradiation with Volumetric Modulated Arc Therapy (VMAT)
    Springer, A.
    Winkler, E.
    Putz, E.
    Altenburger, A.
    Gruber, R.
    Moser, K.
    Track, C.
    Hammer, J.
    Geinitz, H.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S182 - S182