Determination of coronary in-stent restenosis using dual source computed tomography angiography

被引:1
|
作者
Szelid, Z. S. [1 ]
Kerecsen, G.
Maurovich-Horvat, P.
Lux, A.
Marosi, E.
Kovacs, A.
Kiss, R. G.
Preda, I.
Merkely, B.
机构
[1] Semmelweis Univ, Heart Ctr, Varosmajor U 68, H-1122 Budapest, Hungary
来源
关键词
in-stent restenosis; coronary CT angiography; 64-slice dual source scanner; positive predictive value; stent diameter;
D O I
10.1556/IMAS.2.2010.1.2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Diagnostic accuracy of 64-slice CT angiography in the evaluation of in-stent restenosis is improved compared to previous CT methods. The image quality and exact diagnostic performance is, however, limited by several method, stent and patient-related factors. In this retrospective multicenter study the first results with dual source 64-slice scanner are presented in a Hungarian post PCI patient population (n=99). Radiation dose was 11.3 +/- 5.2 mSv (average +/- STD) using a helical scan. In 5.6% of all (n= 142) examined stents clinicians were not able to give a final diagnosis using CT scan. This limitation showed correlation with the stent diameter. Nondiagnostic stents were smaller compared to the diagnostic stents (diameter 2.4 +/- 0.2 mm versus 3.2 +/- 0.5 mm, average +/- STD, respectively, P<0.01). Despite its high negative predictive value in the detection of restenosis, positive predictive value of CTA is lower, than that of invasive angiography. CT was not powerful enough in our study to distinguish vessel occlusion from severe restenosis. Heart rate was decreased by administration of intravenous metoprolol and in 75.8% of the patients scan was performed at a heart rate over 70 beats/minute, which did not have a significant influence on the diagnostic value.
引用
收藏
页码:5 / 9
页数:5
相关论文
共 50 条
  • [31] Diagnostic Accuracy of 320-Row Multidetector Computed Tomography Coronary Angiography to Noninvasively Assess In-Stent Restenosis
    de Graaf, Fleur R.
    Schuijf, Joanne D.
    van Velzen, Joella E.
    Boogers, Mark J.
    Kroft, Lucia J.
    de Roos, Albert
    Reiber, Johannes H. C.
    Sieders, Allard
    Spano, Fabrizio
    Jukema, J. Wouter
    Schalij, Martin J.
    van der Wall, Ernst E.
    Bax, Jeroen J.
    INVESTIGATIVE RADIOLOGY, 2010, 45 (06) : 331 - 340
  • [32] Usefulness of 64-slice multi-slice computed tomography coronary angiography to assess in-stent restenosis
    Schuijf, Joanne D.
    Cademartiri, Filippo
    Pugliese, Francesca
    Mollet, Nico R.
    Jukema, J. Wouter
    Palumbo, Alessandro
    Kroft, Lucia J.
    Ardessino, Diego
    Serruys, Patrick W.
    Krestin, Gabriel P.
    van der Wall, Ernst E.
    de Feyter, Pim J.
    Bax, Jeroen J.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (09) : 113A - 113A
  • [33] In-stent restenosis, evaluation with 16-slice computed tomography coronary scanner
    Dupouy, P
    Champagne, S
    Bougrini, K
    Aptecar, E
    Convard, JP
    Hovasse, D
    Villemant, D
    Auguste, M
    Pernès, JM
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 314A - 314A
  • [34] Diagnostic Performance of Low Radiation Dose and Contrast-Dose Coronary Computed Tomography Angiography in the Detection of Coronary In-Stent Restenosis
    Du, Wang
    Fan, Zhanming
    Wang, Rui
    Xu, Lei
    Li, Jianying
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2018, 8 (08) : 1566 - 1572
  • [35] EVALUATION OF CORONARY STENT PATENCY AT BYPASS GRAFTS USING DUAL SOURCE 64 SLICE COMPUTED TOMOGRAPHY CORONARY ANGIOGRAPHY
    Yorgun, H.
    Hazirolan, T.
    Sunman, H.
    Canpolat, U.
    Ates, A. H.
    Dural, M.
    Sahiner, M. L.
    Kaya, E. B.
    Aytemir, K.
    Tokgozoglu, L.
    Kabakci, G.
    Oto, A.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 147 : S59 - S59
  • [36] Evaluation of in-stent restenosis in proximal coronary arteries with multidetector computed tomography (MDCT)
    V. Chabbert
    D. Carrie
    M. Bennaceur
    E. Maupas
    V. Lauwers
    M. Mhem
    T. Lhermusier
    M. Elbaz
    F. Joffre
    H. Rousseau
    J. Puel
    European Radiology, 2007, 17 : 1452 - 1463
  • [37] In-stent restenosis in coronary arteries evaluated with multislice computed tomography of 64 channels
    Bayol, A.
    Vallejos, J.
    Peloso, R.
    Obregon, R.
    Aguero, M.
    Baccaro, J.
    Mazucco, J.
    Romero, M.
    Vera, M.
    Parras, J.
    CIRCULATION, 2008, 118 (12) : E266 - E266
  • [38] Evaluation of in-stent restenosis in proximal coronary arteries with multidetector computed tomography (MDCT)
    Chabbert, V.
    Carrie, D.
    Bennaceur, M.
    Maupas, E.
    Lauwers, V.
    Mhem, M.
    Lhermusier, T.
    Elbaz, M.
    Joffre, F.
    Rousseau, H.
    Puel, J.
    EUROPEAN RADIOLOGY, 2007, 17 (06) : 1452 - 1463
  • [39] Coronary CT angiography (CCTA) using third-generation dual-source CT for ruling out in-stent restenosis
    Eckert, J.
    Renczes-Janetzko, P.
    Schmidt, M.
    Magedanz, A.
    Voigtlaender, T.
    Schmermund, A.
    CLINICAL RESEARCH IN CARDIOLOGY, 2019, 108 (04) : 402 - 410
  • [40] The usefulness of subtraction coronary computed tomography angiography for in-stent restenosis assessment of patients with CoCr stent using 320-row area detector CT
    Li, Jian
    Guo, Man-Tao
    Yang, Xiao
    Gao, Fang
    Li, Na
    Huang, Ming-Gang
    MEDICINE, 2021, 100 (51) : E28345