Determination of coronary in-stent restenosis using dual source computed tomography angiography

被引:1
|
作者
Szelid, Z. S. [1 ]
Kerecsen, G.
Maurovich-Horvat, P.
Lux, A.
Marosi, E.
Kovacs, A.
Kiss, R. G.
Preda, I.
Merkely, B.
机构
[1] Semmelweis Univ, Heart Ctr, Varosmajor U 68, H-1122 Budapest, Hungary
来源
关键词
in-stent restenosis; coronary CT angiography; 64-slice dual source scanner; positive predictive value; stent diameter;
D O I
10.1556/IMAS.2.2010.1.2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Diagnostic accuracy of 64-slice CT angiography in the evaluation of in-stent restenosis is improved compared to previous CT methods. The image quality and exact diagnostic performance is, however, limited by several method, stent and patient-related factors. In this retrospective multicenter study the first results with dual source 64-slice scanner are presented in a Hungarian post PCI patient population (n=99). Radiation dose was 11.3 +/- 5.2 mSv (average +/- STD) using a helical scan. In 5.6% of all (n= 142) examined stents clinicians were not able to give a final diagnosis using CT scan. This limitation showed correlation with the stent diameter. Nondiagnostic stents were smaller compared to the diagnostic stents (diameter 2.4 +/- 0.2 mm versus 3.2 +/- 0.5 mm, average +/- STD, respectively, P<0.01). Despite its high negative predictive value in the detection of restenosis, positive predictive value of CTA is lower, than that of invasive angiography. CT was not powerful enough in our study to distinguish vessel occlusion from severe restenosis. Heart rate was decreased by administration of intravenous metoprolol and in 75.8% of the patients scan was performed at a heart rate over 70 beats/minute, which did not have a significant influence on the diagnostic value.
引用
收藏
页码:5 / 9
页数:5
相关论文
共 50 条
  • [21] Noninvasive assessment of in-stent restenosis by high definition computed tomography coronary angiography with new gemstone detector
    Tsuda, T.
    Mihara, H.
    EUROPEAN HEART JOURNAL, 2012, 33 : 91 - 91
  • [22] Noninvasive Assessment of In-Stent Restenosis by High Definition Computed Tomography Coronary Angiography with New Gemstone Detector
    Mihara, Hirotsugu
    Kanashiro, Masaaki
    Tsuda, Takuma
    Miki, Yusuke
    Aoki, Toshijirou
    Mitsuda, Takayuki
    Hayano, Shinji
    Suzuki, Susumu
    Aoyama, Toru
    Watanabe, Junji
    Ichimiya, Satoshi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) : B166 - B166
  • [23] Noninvasive assessment of in-stent restenosis by high definition computed tomography coronary angiography with new gemstone detector
    Mihara, H.
    Tsuda, T.
    Hayano, S.
    Ogawa, K.
    Sakakibara, T.
    Suzuki, S.
    Aoyama, T.
    Watanabe, J.
    Kanashiro, M.
    Ichimiya, S.
    EUROPEAN HEART JOURNAL, 2011, 32 : 523 - 523
  • [24] Evaluation of coronary stent patency and in-stent restenosis with dual-source CT coronary angiography without heart rate control
    Oncel, Dilek
    Oncel, Guray
    Tastan, Ahmet
    Tamci, Batuhan
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (01) : 56 - 63
  • [25] Diagnosis of coronary in-stent restenosis with multidetector row spiral computed tomography
    Gaspar, T
    Halon, DA
    Lewis, BS
    Adawi, S
    Schliamser, JE
    Rubinshtein, R
    Flugelman, MY
    Peled, N
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (08) : 1573 - 1579
  • [26] Comparison of Invasive Coronary Angiography Versus Computed Tomography Angiography to Assess Mehran Classification of In-Stent Restenosis in Bifurcation Percutaneous Coronary Intervention
    Naeem, Hesham
    Khan, Umar
    Mohsin, Muhammad
    Niazi, Khurram
    Malik, Jahanzeb
    Satti, Danish Iltaf
    Anwar, Waqas
    AMERICAN JOURNAL OF CARDIOLOGY, 2022, 172 : 11 - 17
  • [27] Coronary In-Stent Restenosis: Assessment with CT Coronary Angiography
    Andreini, Daniele
    Pontone, Gianluca
    Mushtaq, Saima
    Bartorelli, Antonio L.
    Bertella, Erika
    Trabattoni, Daniela
    Montorsi, Piero
    Galli, Stefano
    Foti, Claudia
    Annoni, Andrea
    Bovis, Francesca
    Ballerini, Giovanni
    Agostoni, Piergiuseppe
    Fiorentini, Cesare
    Pepi, Mauro
    RADIOLOGY, 2012, 265 (02) : 410 - 417
  • [28] The utility and effectiveness of the newer generation high-resolution coronary computed tomography angiography in the evaluation of coronary in-stent restenosis
    Elwany, Mostafa N.
    Abskharoun, Michael
    Dawood, Moustafa
    Al-Tahan, Salah M.
    Sanhoury, Mohamed
    CURRENT PROBLEMS IN CARDIOLOGY, 2024, 49 (02)
  • [29] Multislice spiral computed tomography for in-stent restenosis
    Storto, ML
    Marano, R
    Maddestra, N
    Caputo, M
    Zimarino, M
    Bonomo, L
    CIRCULATION, 2002, 105 (16) : 2005 - 2005
  • [30] Dual-source CT angiography for detection and quantification of in-stent restenosis in the left main coronary artery
    Veselka, J.
    Zemanek, D.
    Cadova, P.
    Hajek, P.
    Tomasov, P.
    Maly, M.
    Adla, T.
    EUROPEAN HEART JOURNAL, 2011, 32 : 525 - 525