Coronary CT angiography (CCTA) using third-generation dual-source CT for ruling out in-stent restenosis

被引:23
|
作者
Eckert, J. [1 ]
Renczes-Janetzko, P. [1 ]
Schmidt, M. [1 ]
Magedanz, A. [1 ]
Voigtlaender, T. [1 ]
Schmermund, A. [1 ]
机构
[1] Cardioangiol Ctr Bethanien, Pruefling 23, D-60389 Frankfurt, Germany
关键词
Coronary computed tomography angiography; Coronary stents; In-stent stenosis; BMS; DES; Third-generation dual-source CT; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; ITERATIVE RECONSTRUCTION; NEOATHEROSCLEROSIS; ASSOCIATION;
D O I
10.1007/s00392-018-1369-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
AimsLate in-stent restenosis (ISR) has become increasingly important, in particular due to neo-atherosclerosis. CCTA is a highly sensitive method for detecting coronary plaques. Its diagnostic accuracy regarding ISR is controversial. Stent artifacts can impede image quality, but recent developments in CT-technology may help to overcome some of these problems and allow for improved diagnostic accuracy.MethodsConsecutive patients after previous coronary revascularization who had stable symptoms or signs of possible disease progression were examined using a third-generation dual-source CT scanner. After the scan, patients were followed for clinical events (MACE) over a mean of 399 days. Patients with high-grade stenoses were referred for invasive coronary angiography (ICA), unclear findings were further evaluated either by ICA or functional testing.ResultsOverall, 226 patients were included. A total of 457 stents were evaluated (2.01.4 per patient). Mean stent diameter was 2.9 +/- 0.45mm. In 61%, a high-pitch protocol was employed. Mean dose-length product (DLP) of CCTA was 159.2 mGycm, corresponding to 2.2mSv using a conversion factor of k=0.014. Mean amount of contrast agent was 58.3 +/- 12.5ml. In 145 patients (64%), CCTA was negative. In this group, one MACE occurred (acute coronary syndrome) during follow-up in a patient who had also undergone unremarkable ICA. In 23 patients (10%), CCTA detected 28 ISR which were confirmed and treated by ICA (true positive). In 27 patients (12%), ISR was suspected by CCTA but excluded by ICA (false positive), 30 patients (13%) had unclear findings and normal non-invasive tests. No MACE occurred during follow-up in these patients. One patient was misclassified in CCTA as having intermediate and not high-grade ISR who underwent revascularization within 3 months. Eleven patients (5%) were lost to follow-up. During follow-up, eight patients had myocardial infarctions due to five ISRs and three de novo lesions. No patient died. In cases with unclear or false-positive findings, the amount of stents was significantly higher, stents were smaller and patients had a higher BMI.Conclusionp id=Par4In almost two-thirds of symptomatic patients with previous coronary stent implantation, ISR could be ruled out by CCTA. 10% of patients had definite ISR. The rate of false-negative findings was low (<1%), whereas the rate of false positive or inconclusive findings was 25%, leading to invasive rule-out of ISR by ICA in 12%. CCTA appears valuable as a tool for safely excluding ISR. It might help to avoid invasive diagnostic procedures. Further analyses are warranted, in particular regarding the influence of stent dimensions and the total amount of stents in a patient.
引用
收藏
页码:402 / 410
页数:9
相关论文
共 50 条
  • [1] Coronary CT angiography (CCTA) using third-generation dual-source CT for ruling out in-stent restenosis
    J. Eckert
    P. Renczes-Janetzko
    M. Schmidt
    A. Magedanz
    T. Voigtländer
    A. Schmermund
    Clinical Research in Cardiology, 2019, 108 : 402 - 410
  • [2] Dual-source CT angiography for detection and quantification of in-stent restenosis in the left main coronary artery
    Veselka, J.
    Zemanek, D.
    Cadova, P.
    Hajek, P.
    Tomasov, P.
    Maly, M.
    Adla, T.
    EUROPEAN HEART JOURNAL, 2011, 32 : 525 - 525
  • [3] Evaluation of coronary stent patency and in-stent restenosis with dual-source CT coronary angiography without heart rate control
    Oncel, Dilek
    Oncel, Guray
    Tastan, Ahmet
    Tamci, Batuhan
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (01) : 56 - 63
  • [4] Limits of the possible: diagnostic image quality in coronary angiography with third-generation dual-source CT
    Marco M. Ochs
    Fabian aus dem Siepen
    Thomas Fritz
    Florian Andre
    Gitsios Gitsioudis
    Grigorios Korosoglou
    Sebastian Seitz
    Yuriy Bogomazov
    Christopher L. Schlett
    Roman Sokiranski
    Andre Sommer
    Friedemann Gückel
    Matthias Brado
    Hans-Ulrich Kauczor
    Johannes Görich
    Matthias G. W. Friedrich
    Hugo A. Katus
    Sebastian J. Buss
    Clinical Research in Cardiology, 2017, 106 : 485 - 492
  • [5] Limits of the possible: diagnostic image quality in coronary angiography with third-generation dual-source CT
    Ochs, Marco M.
    Siepen, Fabian Aus Dem
    Fritz, Thomas
    Andre, Florian
    Gitsioudis, Gitsios
    Korosoglou, Grigorios
    Seitz, Sebastian
    Bogomazov, Yuriy
    Schlett, Christopher L.
    Sokiranski, Roman
    Sommer, Andre
    Gueckel, Friedemann
    Brado, Matthias
    Kauczor, Hans-Ulrich
    Goerich, Johannes
    Friedrich, Matthias G. W.
    Katus, Hugo A.
    Buss, Sebastian J.
    CLINICAL RESEARCH IN CARDIOLOGY, 2017, 106 (07) : 485 - 492
  • [6] Iterative reconstruction improves detection of in-stent restenosis by high-pitch dual-source coronary CT angiography
    Yang, Junjie
    Yang, Xiaobo
    De Cecco, Carlo N.
    Duguay, Taylor M.
    Chen, Zhiye
    Tesche, Christian
    Schoepf, U. Joseph
    Chen, Yundai
    SCIENTIFIC REPORTS, 2017, 7
  • [7] Iterative reconstruction improves detection of in-stent restenosis by high-pitch dual-source coronary CT angiography
    Junjie Yang
    Xiaobo Yang
    Carlo N. De Cecco
    Taylor M. Duguay
    Zhiye Chen
    Christian Tesche
    U. Joseph Schoepf
    Yundai Chen
    Scientific Reports, 7
  • [8] Radiation dose of coronary CT angiography with a third-generation dual-source CT in a "real-world" patient population
    Kosmala, Aleksander
    Petritsch, Bernhard
    Weng, Andreas Max
    Bley, Thorsten Alexander
    Gassenmaier, Tobias
    EUROPEAN RADIOLOGY, 2019, 29 (08) : 4341 - 4348
  • [9] Radiation dose of coronary CT angiography with a third-generation dual-source CT in a “real-world” patient population
    Aleksander Kosmala
    Bernhard Petritsch
    Andreas Max Weng
    Thorsten Alexander Bley
    Tobias Gassenmaier
    European Radiology, 2019, 29 : 4341 - 4348
  • [10] Dual-Source CT Angiography for Detection and Quantification of In-Stent Restenosis in the Left Main Coronary Artery: Comparison with Intracoronary Ultrasound and Coronary Angiography
    Veselka, Josef
    Cadova, Pavla
    Tomasov, Pavol
    Theodor, Adla
    Zemanek, David
    JOURNAL OF INVASIVE CARDIOLOGY, 2011, 23 (11): : 460 - 464