FEASIBILITY STUDY FOR POSITRON EMISSION MAMMOGRAPHY

被引:133
|
作者
THOMPSON, CJ
MURTHY, K
WEINBERG, IN
MAKO, F
机构
[1] MCGILL UNIV,MONTREAL NEUROL INST,MONTREAL,PQ,CANADA
[2] JOHNS HOPKINS UNIV,DEPT RADIOL,BALTIMORE,MD
[3] FM TECHNOL INC,FAIRFAX,VA
关键词
PET; MAMMOGRAPHY; SPATIAL RESOLUTION;
D O I
10.1118/1.597169
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A feasibility study is presented for a small, low-cost, dedicated device for positron emission mammography. Two detector arrays above and below the breast would be placed in a conventional mammography unit. These detectors are sensitive to positron annihilation radiation, and are connected to a coincidence circuit and a multiplane image memory. Images of the distribution of positron-emitting isotope are obtained in real time by incrementing the memory location at the intersection of each line of response. Monte Carlo simulations of a breast phantom are compared with actual scans of this phantom in a conventional PET scanner. The simulations and experimental data are used to predict the performance of the proposed system. Spatial resolution experiments using very narrow bismuth germanate BGO crystals suggest that spatial resolutions of about 2 mm should be possible. The efficiency of the proposed device is about ten times that of a conventional brain scanner. The scatter fraction is greater, but the scattered radiation has a very flat distribution. By designing the device to fit in an existing mammography unit, conventional mammograms can be taken after the injection of the radio-pharmaceutical allowing exact registration of the emission and conventional mammographic images.
引用
收藏
页码:529 / 538
页数:10
相关论文
共 50 条
  • [21] Targeted Image Reconstruction in Positron Emission Mammography
    Picado, G.
    Matela, N.
    Oliveira, N.
    Almeida, P.
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 5, 2009, 25 : 358 - 361
  • [22] Development of a Commercial Positron Emission Mammography (PEM)
    Miyake, Masayasu
    Yamamoto, Seiichi
    Itoh, Masatoshi
    Kumagai, Kazuaki
    Sasaki, Takehisa
    dos Santos, Targino Rodrigues
    Tashiro, Manabu
    Baba, Mamoru
    [J]. 13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3): : 2248 - +
  • [23] Positron Emission Mammography: Initial Clinical Results
    Edward A. Levine
    Rita I. Freimanis
    Nancy D. Perrier
    Kathryn Morton
    Nadia M. Lesko
    Simon Bergman
    Kim R. Geisinger
    Rodney C. Williams
    Connie Sharpe
    Valera Zavarzin
    Irving N. Weinberg
    Pavel Y. Stepanov
    David Beylin
    Kathryn Lauckner
    Mohan Doss
    Judy Lovelace
    Lee P. Adler
    [J]. Annals of Surgical Oncology, 2003, 10 : 86 - 91
  • [24] AvanTomography: A Compact Module for Positron Emission Mammography
    Us, D.
    Moreno-Galera, A.
    Nazari-Farsani, S.
    Palovuori, K.
    Kosola, H.
    Zedda, T.
    Ruotsalainen, U.
    [J]. 2015 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA) PROCEEDINGS, 2015, : 52 - 57
  • [25] Shielding calculations for a positron emission mammography facility
    Chacko, Stephanie
    Zimmer, Michael
    McDonald, Nancy
    Spies, Stewart
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [26] Positron emission mammography: Initial clinical results
    Levine, EA
    Freimanis, RI
    Perrier, ND
    Morton, K
    Lesko, NM
    Bergman, S
    Geisinger, KR
    Williams, RC
    Sharpe, C
    Zavarzin, V
    Weinberg, IN
    Stepanov, PY
    Beylin, D
    Lauckner, K
    Doss, M
    Lovelace, J
    Adler, LP
    [J]. ANNALS OF SURGICAL ONCOLOGY, 2003, 10 (01) : 86 - 91
  • [27] Positron emission mammography with multiple angle acquisition
    Smith, MF
    Majewski, S
    Raylman, RR
    [J]. 2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1892 - 1896
  • [28] VALUE OF BREAST COMPRESSION IN POSITRON EMISSION MAMMOGRAPHY
    WEINBERG, IN
    WEISENBERGER, A
    MAJEWSKI, S
    MARKOWITZ, A
    THOMPSON, CJ
    ALOJ, L
    [J]. RADIOLOGY, 1995, 197 : 353 - 353
  • [29] An apparatus for positron emission mammography guided biopsy
    Raylman, RR
    Majewski, S
    Wojcik, R
    Weisenberger, AG
    Kross, B
    Popov, V
    Schreiman, JS
    Bishop, HA
    [J]. 1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1323 - 1327
  • [30] Lesion detection and quantitation of Positron Emission Mammography
    Qi, JY
    Fluesman, RH
    [J]. 2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 2248 - 2252