Positron emission mammography with multiple angle acquisition

被引:0
|
作者
Smith, MF [1 ]
Majewski, S [1 ]
Raylman, RR [1 ]
机构
[1] Thomas Jefferson Natl Accelerator Facil, Newport News, VA 23606 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Positron emission mammography (PEM) of F-18 fluorodeoxyglucose (FDG) uptake in breast tumors with dedicated detectors typically has been accomplished with two planar detectors in a fixed position with the breast under compression. The potential use of PEM imaging at two detector positions to guide stereotactic breast biopsy has motivated us to use PEM coincidence data acquired at two or more detector positions together in a single image reconstruction. Multiple angle PEM acquisition and iterative image reconstruction were investigated using point source and compressed breast phantom acquisitions with 5, 9, 12 and 15 mm diameter spheres and a simulated tumor: background activity concentration ratio of 6:1. Image reconstruction was performed with an iterative MLEM algorithm that used coincidence events between any two detector pixels on opposed detector heads at each detector position. This present study compared two acquisition protocols: 2 angle acquisition with detector angular positions of -15 and +15 degrees and 11 angle acquisition with detector positions spaced at 3 degree increments over the range -15 to +15 degrees. Three-dimensional image resolution was assessed for the point source acquisitions, and contrast and signal-to-noise metrics were evaluated for the compressed breast phantom with different simulated tumor sizes. Radial and tangential resolutions were similar for the two protocols, while normal resolution was better for the 2 angle acquisition. Analysis is complicated by the asymmetric point spread functions. Signal-to-noise vs. contrast tradeoffs were better for 11 angle acquisition for the smallest visible 9 mm sphere, while tradeoff results were mixed for the larger and more easily visible 12 mm and 15 mm diameter spheres. Additional study is needed to better understand the performance of limited angle tomography for PEM. PEM tomography experiments with complete angular sampling are planned.
引用
下载
收藏
页码:1892 / 1896
页数:5
相关论文
共 50 条
  • [1] Data acquisition electronics for positron emission mammography (PEM) detectors
    Martínez, JD
    Sebastiá, A
    Cerdá, J
    Esteve, R
    Mora, FJ
    Toledo, JF
    Benlloch, JM
    Giménez, N
    Giménez, M
    Lerche, CW
    Pavón, N
    Sánchez, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 537 (1-2): : 335 - 338
  • [2] A flexible acquisition system for modular dual head Positron Emission Mammography
    Sportelli, Giancarlo
    Attanasi, Francesca
    Belcari, Nicola
    Franchi, Giovanni
    Guerra, Pedro
    Moehrs, Sascha
    Rosso, Valeria
    Santos, Andres
    Spinella, Franco
    Vecchio, Sara
    Del Guerra, Alberto
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3395 - +
  • [3] Positron emission mammography (PEM)
    Garcia-Gomez, Jaime I.
    Villasenor-Navarro, Yolanda
    GACETA MEXICANA DE ONCOLOGIA, 2012, 11 (04): : 281 - 287
  • [4] Positron emission mammography imaging
    Moses, WW
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 525 (1-2): : 249 - 252
  • [5] Applications for positron emission mammography
    Weinberg, Irving N.
    PHYSICA MEDICA, 2006, 21 : 132 - 137
  • [6] Instrumentation for Positron Emission Mammography
    Thompson, Christopher J.
    PET CLINICS, 2006, 1 (01) : 33 - 38
  • [7] Positron emission mammography with tomographic acquisition using dual planar detectors: initial evaluations
    Smith, MF
    Raylmann, RR
    Majewski, S
    Weisenberger, AG
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (11): : 2437 - 2452
  • [8] A high-performance VME-based acquisition system for positron emission mammography
    Abbott, DJ
    Weisenberger, A
    Majewski, S
    Kieper, D
    Kross, B
    Popov, V
    Wojick, R
    Raylman, RR
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1947 - 1951
  • [9] Instrumentation optimization for Positron Emission Mammography
    Moses, WW
    Qi, JY
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 527 (1-2): : 76 - 82
  • [10] Fundamental limits of positron emission mammography
    Moses, WW
    Qi, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 497 (01): : 82 - 89