Positron emission mammography with multiple angle acquisition

被引:0
|
作者
Smith, MF [1 ]
Majewski, S [1 ]
Raylman, RR [1 ]
机构
[1] Thomas Jefferson Natl Accelerator Facil, Newport News, VA 23606 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Positron emission mammography (PEM) of F-18 fluorodeoxyglucose (FDG) uptake in breast tumors with dedicated detectors typically has been accomplished with two planar detectors in a fixed position with the breast under compression. The potential use of PEM imaging at two detector positions to guide stereotactic breast biopsy has motivated us to use PEM coincidence data acquired at two or more detector positions together in a single image reconstruction. Multiple angle PEM acquisition and iterative image reconstruction were investigated using point source and compressed breast phantom acquisitions with 5, 9, 12 and 15 mm diameter spheres and a simulated tumor: background activity concentration ratio of 6:1. Image reconstruction was performed with an iterative MLEM algorithm that used coincidence events between any two detector pixels on opposed detector heads at each detector position. This present study compared two acquisition protocols: 2 angle acquisition with detector angular positions of -15 and +15 degrees and 11 angle acquisition with detector positions spaced at 3 degree increments over the range -15 to +15 degrees. Three-dimensional image resolution was assessed for the point source acquisitions, and contrast and signal-to-noise metrics were evaluated for the compressed breast phantom with different simulated tumor sizes. Radial and tangential resolutions were similar for the two protocols, while normal resolution was better for the 2 angle acquisition. Analysis is complicated by the asymmetric point spread functions. Signal-to-noise vs. contrast tradeoffs were better for 11 angle acquisition for the smallest visible 9 mm sphere, while tradeoff results were mixed for the larger and more easily visible 12 mm and 15 mm diameter spheres. Additional study is needed to better understand the performance of limited angle tomography for PEM. PEM tomography experiments with complete angular sampling are planned.
引用
下载
收藏
页码:1892 / 1896
页数:5
相关论文
共 50 条
  • [21] Development of a Commercial Positron Emission Mammography (PEM)
    Miyake, Masayasu
    Yamamoto, Seiichi
    Itoh, Masatoshi
    Kumagai, Kazuaki
    Sasaki, Takehisa
    dos Santos, Targino Rodrigues
    Tashiro, Manabu
    Baba, Mamoru
    13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3): : 2248 - +
  • [22] AvanTomography: A Compact Module for Positron Emission Mammography
    Us, D.
    Moreno-Galera, A.
    Nazari-Farsani, S.
    Palovuori, K.
    Kosola, H.
    Zedda, T.
    Ruotsalainen, U.
    2015 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA) PROCEEDINGS, 2015, : 52 - 57
  • [23] Positron Emission Mammography: Initial Clinical Results
    Edward A. Levine
    Rita I. Freimanis
    Nancy D. Perrier
    Kathryn Morton
    Nadia M. Lesko
    Simon Bergman
    Kim R. Geisinger
    Rodney C. Williams
    Connie Sharpe
    Valera Zavarzin
    Irving N. Weinberg
    Pavel Y. Stepanov
    David Beylin
    Kathryn Lauckner
    Mohan Doss
    Judy Lovelace
    Lee P. Adler
    Annals of Surgical Oncology, 2003, 10 : 86 - 91
  • [24] Positron emission mammography: Initial clinical results
    Levine, EA
    Freimanis, RI
    Perrier, ND
    Morton, K
    Lesko, NM
    Bergman, S
    Geisinger, KR
    Williams, RC
    Sharpe, C
    Zavarzin, V
    Weinberg, IN
    Stepanov, PY
    Beylin, D
    Lauckner, K
    Doss, M
    Lovelace, J
    Adler, LP
    ANNALS OF SURGICAL ONCOLOGY, 2003, 10 (01) : 86 - 91
  • [25] Shielding calculations for a positron emission mammography facility
    Chacko, Stephanie
    Zimmer, Michael
    McDonald, Nancy
    Spies, Stewart
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [26] VALUE OF BREAST COMPRESSION IN POSITRON EMISSION MAMMOGRAPHY
    WEINBERG, IN
    WEISENBERGER, A
    MAJEWSKI, S
    MARKOWITZ, A
    THOMPSON, CJ
    ALOJ, L
    RADIOLOGY, 1995, 197 : 353 - 353
  • [27] Lesion detection and quantitation of Positron Emission Mammography
    Qi, JY
    Fluesman, RH
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 2248 - 2252
  • [28] An apparatus for positron emission mammography guided biopsy
    Raylman, RR
    Majewski, S
    Wojcik, R
    Weisenberger, AG
    Kross, B
    Popov, V
    Schreiman, JS
    Bishop, HA
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1323 - 1327
  • [29] Evaluation of a high resolution positron emission tomography (PET) scanner for positron emission mammography (PEM)
    White, LL
    Ott, RJ
    Carnochan, P
    Duxbury, DM
    Bruyndonckx, P
    Tavernier, S
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1236 - 1240
  • [30] Simulation of Positron Emission Mammography Imaging with Pixelated CdTe
    Kolstein, Machiel
    Chmeissani, Mokhtar
    BREAST IMAGING, IWDM 2016, 2016, 9699 : 122 - 129