Shape and Contact Force Estimation of Inserted Flexible Medical Device

被引:0
|
作者
Hwan-Taek Ryu
Jaehong Woo
Byung-Rok So
Byung-Ju Yi
机构
[1] Hanyang University,Department of Intelligent Robot Engineering
[2] Robotics R&BD Group,Department of Electronic Systems Engineering
[3] Korea Institute of Industrial Technology(KITECH),undefined
[4] Hanyang University,undefined
关键词
Cosserat-rod theory; flexible colonoscope; kinematically redundancy; multiple contact force estimation; shape estimation;
D O I
暂无
中图分类号
学科分类号
摘要
Flexible devices such as colonoscopy tube or catheter being inserted into the human-body make contact with the human tissues at several locations. Excessive contact force may damage the human tissues. To cope with this problem, the first aim of this paper is the shape estimation of the flexible body inside the human body using only two electromagnetic sensors. For this, the flexible body is modeled as kinematically redundant manipulator with many joints and links. The second aim is to estimate contact forces at a point, line contact, and multiple points. Cosserat-rod theory is employed to solve this problem. The effectiveness of the proposed algorithms is proved through both experiment and simulation for a flexible colonoscopy tube.
引用
收藏
页码:163 / 174
页数:11
相关论文
共 50 条
  • [41] Model-based estimation of contact forces in flexible structures
    Krajcin, I
    Söffker, D
    MATHEMATICAL AND COMPUTER MODELLING OF DYNAMICAL SYSTEMS, 2004, 10 (3-4) : 303 - 316
  • [42] Precise Force Control for Contact with Flexible Object Considering Environmental Dynamics
    Kurumatani, Hiroki
    Katsura, Seiichiro
    2017 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS (ICM), 2017, : 172 - 177
  • [43] Micro ECDM scanning process with feedback control of flexible contact force
    Nawaz, Shan Ali
    Cao, Peiyao
    Tong, Hao
    Li, Yong
    JOURNAL OF MANUFACTURING PROCESSES, 2023, 94 : 266 - 277
  • [44] Shape Estimation Algorithm for Ultrasound Imaging by Flexible Array Transducer
    Noda, Takumi
    Tomii, Naoki
    Nakagawa, Keiichi
    Azuma, Takashi
    Sakuma, Ichiro
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2020, 67 (11) : 2345 - 2353
  • [45] Shape estimation of the anterior part of a flexible ureteroscope for intraoperative navigation
    Zhang, Chongan
    Hu, Chunyong
    He, Zhongyu
    Fu, Zuoming
    Xu, Lixin
    Ding, Guoqing
    Wang, Peng
    Zhang, Hong
    Ye, Xuesong
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2022, 17 (10) : 1787 - 1799
  • [46] Safety and effectiveness of the first contact force ablation catheter with a flexible tip
    Nair, Devi
    Martinek, Martin
    Colley, Judson
    Sundaram, Sri
    Hariharan, Ramesh
    Morales, Gustavo
    Sommer, Philipp
    Healy, Stewart
    Siddiqui, Usman
    Gibson, Douglas
    Chapman, Kristina
    Sarver, Anne
    Lo, Monica
    HEART RHYTHM O2, 2023, 4 (12): : 784 - 793
  • [47] Adaptive position/force control for robot manipulator in contact with a flexible environment
    Gierlak, Piotr
    Szuster, Marcin
    ROBOTICS AND AUTONOMOUS SYSTEMS, 2017, 95 : 80 - 101
  • [48] Contact Force Minimization for Space Flexible Manipulators Based on Effective Mass
    Chen, Gang
    Liu, Dan
    Wang, Yifan
    Jia, Qingxuan
    Liu, Xin
    JOURNAL OF GUIDANCE CONTROL AND DYNAMICS, 2019, 42 (08) : 1870 - 1877
  • [49] Shape estimation of the anterior part of a flexible ureteroscope for intraoperative navigation
    Chongan Zhang
    Chunyong Hu
    Zhongyu He
    Zuoming Fu
    Lixin Xu
    Guoqing Ding
    Peng Wang
    Hong Zhang
    Xuesong Ye
    International Journal of Computer Assisted Radiology and Surgery, 2022, 17 : 1787 - 1799
  • [50] Flexible pressure and force sensing system for wearable medical devices
    Xue, Ning
    Liu, Chunxiu
    Sun, Jianhai
    Wang, Chao
    2018 IEEE 8TH INTERNATIONAL NANOELECTRONICS CONFERENCES (INEC), 2018, : 39 - 40