Shape and Contact Force Estimation of Inserted Flexible Medical Device

被引:0
|
作者
Hwan-Taek Ryu
Jaehong Woo
Byung-Rok So
Byung-Ju Yi
机构
[1] Hanyang University,Department of Intelligent Robot Engineering
[2] Robotics R&BD Group,Department of Electronic Systems Engineering
[3] Korea Institute of Industrial Technology(KITECH),undefined
[4] Hanyang University,undefined
关键词
Cosserat-rod theory; flexible colonoscope; kinematically redundancy; multiple contact force estimation; shape estimation;
D O I
暂无
中图分类号
学科分类号
摘要
Flexible devices such as colonoscopy tube or catheter being inserted into the human-body make contact with the human tissues at several locations. Excessive contact force may damage the human tissues. To cope with this problem, the first aim of this paper is the shape estimation of the flexible body inside the human body using only two electromagnetic sensors. For this, the flexible body is modeled as kinematically redundant manipulator with many joints and links. The second aim is to estimate contact forces at a point, line contact, and multiple points. Cosserat-rod theory is employed to solve this problem. The effectiveness of the proposed algorithms is proved through both experiment and simulation for a flexible colonoscopy tube.
引用
收藏
页码:163 / 174
页数:11
相关论文
共 50 条
  • [31] Model Estimation and Control of Compliant Contact Normal Force
    Azad, Morteza
    Ortenzi, Valerio
    Lin, Hsiu-Chin
    Rueckert, Elmar
    Mistry, Michael
    2016 IEEE-RAS 16TH INTERNATIONAL CONFERENCE ON HUMANOID ROBOTS (HUMANOIDS), 2016, : 442 - 447
  • [32] Estimation of Contact Forces using a Virtual Force Sensor
    Magrini, Emanuele
    Flacco, Fabrizio
    De Luca, Alessandro
    2014 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS 2014), 2014, : 2126 - 2133
  • [33] Contact force estimation for complaint robot motion control
    Garcia, Javier Gamez
    Robertsson, Anders
    Ortega, Juan Gomez
    Johansson, Rolf
    REVISTA IBEROAMERICANA DE AUTOMATICA E INFORMATICA INDUSTRIAL, 2007, 4 (01): : 70 - +
  • [34] Contact Force Estimation from Raw Photoplethysmogram Signal
    Fortin, Pascal E.
    Blum, Jeffrey R.
    Weill-Duflos, Antoine
    Cooperstock, Jeremy R.
    2020 IEEE SENSORS, 2020,
  • [35] Position and force control of flexible manipulator with position sensitive device
    Suzuki, J
    Murakami, T
    Ohnishi, K
    7TH INTERNATIONAL WORKSHOP ON ADVANCED MOTION CONTROL, PROCEEDINGS, 2002, : 414 - 419
  • [36] The contact lens as a medical device for delivering glaucoma drugs
    Schultz, CL
    Mint, J
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U303 - U303
  • [37] Force Control Implementation of a Haptic Device for a Medical Use
    Saafi, H.
    Laribi, M. A.
    Zeghloul, S.
    ROBOTICS AND MECHATRONICS, 2016, 37 : 143 - 151
  • [38] Estimation method of static height of contact wire by using pantograph contact force
    Usuda, Takayuki
    Ikeda, Mitsuru
    Quarterly Report of RTRI (Railway Technical Research Institute), 2015, 56 (03) : 175 - 180
  • [39] Contact Force Control on Soft Membrane for an Ear Surgical Device
    Liang, Wenyu
    Ma, Jun
    Tan, Kok Kiong
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (12) : 9593 - 9603
  • [40] Flexible-Device Injector with a Microflap Array for Subcutaneously Implanting Flexible Medical Electronics
    Song, Kwangsun
    Kim, Juho
    Cho, Sungbum
    Kim, Namyun
    Jung, Dongwuk
    Choo, Hyuck
    Lee, Jongho
    ADVANCED HEALTHCARE MATERIALS, 2018, 7 (15)