Positional dependence of the CT number with use of a cone-beam CT scanner for an electron density phantom in particle beam therapy

被引:3
|
作者
Kusano Y. [1 ]
Uesaka S. [2 ]
Yajima K. [2 ]
Kumagai M. [3 ]
Mizuno H. [3 ]
Mori S. [3 ]
机构
[1] Promotion Division of Heavy Ion Facilities, Kanagawa Cancer Center, 1-1-2 Nakao, Asahi-ku, Yokohama
[2] Therapy-Level Dose Calibration Center, Association for Nuclear Technology in Medicine, 3-9-19 Kurosunadai, Inage-Ku
[3] Department of Accelerator Physics and Medical Physics, Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku
关键词
Cone-beam CT; CT number; Electron density; Heel effect; QA;
D O I
10.1007/s12194-012-0194-x
中图分类号
学科分类号
摘要
We evaluated the CT number accuracy in determining a CT calibration method for treatment planning by use of a 256 multi-slice CT (MSCT) scanner. An electron density phantom, which extends full length in the longitudinal direction, was scanned by the 256 MSCT scanner in a single rotation. We inserted four types of samples (air, 100 % ethanol, 40 wt% aqueous K2HPO 4, and water) into the phantom. The regions of interest were set for all image slices, and the average CT number was calculated in the transverse and longitudinal sections. For the transverse image direction, the CT number became lower toward the center of the phantom with almost all samples. The causes of these phenomena might be attributed to the effects of scattered radiation and those of beam hardening due to the high-atomic-number material (40 wt% aqueous K2HPO4). However, the phenomena were too complicated to allow us to determine their causes only from the present studies. Meanwhile, for increasing the accuracy of the CT number calibration, a single sample should be inserted, and this step should be repeated with different samples. For the longitudinal direction, the CT number for a 40 wt % aqueous K 2HPO4 sample increased by 30 HU from the anode to the cathode side due to variations in the X-ray energy caused by the heel effect. The caveat is that the CT number varies in the longitudinal direction when a CT scanner with a wide beam width is used. © 2012 Japanese Society of Radiological Technology and Japan Society of Medical Physics.
引用
收藏
页码:241 / 247
页数:6
相关论文
共 50 条
  • [1] Deformed Planning CT as An Electron Density Substitute for Cone-Beam CT
    Mishra, K.
    Godley, A.
    MEDICAL PHYSICS, 2014, 41 (06) : 164 - 165
  • [2] Phantom development for artifact reduction in cone-beam CT
    Keely, A.
    Kyprianou, I.
    Jennings, R.
    Myers, K.
    Gilat-Schmidt, T.
    MEDICAL PHYSICS, 2007, 34 (06) : 2340 - 2340
  • [3] Helical cone-beam CT for radiation therapy
    Yu, LF
    Pan, XC
    Pelizzari, CA
    Zou, Y
    Munro, P
    Riem, H
    Kaissl, W
    MEDICAL PHYSICS, 2005, 32 (06) : 1890 - 1890
  • [4] Use of cone-beam CT in prostate IMRT
    Jang, S.
    Hurley, A. A.
    Curran, B. H.
    DiPetrillo, T.
    Cardarelli, G. A.
    Sternick, E. S.
    Wazer, D. E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S575 - S575
  • [5] Cone-Beam CT for Breast Specimens in Surgery: The Phantom Study
    Thongvigitmanee, Saowapak S.
    Aootaphao, Sorapong
    Thanasupsombat, Chalinee
    Kiang-ia, Atthasak
    Narkbuakaew, Walita
    Wangkaoom, Kongyot
    Junhunee, Parinya
    Laohawiriyakamol, Suphawat
    Puttawibul, Puttisak
    Thajchayapong, Pairash
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [6] A Novel Phantom for Electron Density Calibration of Linac Cone Beam CT Options
    Cossmann, P.
    MEDICAL PHYSICS, 2010, 37 (06) : 3428 - +
  • [7] Quantifying breast density with a cone-beam breast CT
    Li, Xinhua
    Liu, Bob
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [8] Peripheral Quantitative CT (pQCT) Using a Dedicated Extremity Cone-Beam CT Scanner
    Muhit, A. A.
    Arora, S.
    Ogawa, M.
    Ding, Y.
    Zbijewski, W.
    Stayman, J. W.
    Thawait, G.
    Packard, N.
    Senn, R.
    Yang, D.
    Yorkston, J.
    Bingham, C. O., III
    Means, K.
    Carrino, J. A.
    Siewerdsen, J. H.
    MEDICAL IMAGING 2013: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2013, 8672
  • [9] A cone-beam megavoltage CT scanner for treatment verification in conformal radiotherapy
    Mosleh-Shirazi, MA
    Evans, PM
    Swindell, W
    Webb, S
    Partridge, M
    RADIOTHERAPY AND ONCOLOGY, 1998, 48 (03) : 319 - 328
  • [10] Image quality and dose for a multisource cone-beam CT extremity scanner
    Gang, Grace J.
    Zbijewski, Wojciech
    Mahesh, Mahadevappa
    Thawait, Gaurav
    Packard, Nathan
    Yorkston, John
    Demehri, Shadpour
    Siewerdsen, Jeffrey H.
    MEDICAL PHYSICS, 2018, 45 (01) : 144 - 155