Positional dependence of the CT number with use of a cone-beam CT scanner for an electron density phantom in particle beam therapy

被引:3
|
作者
Kusano Y. [1 ]
Uesaka S. [2 ]
Yajima K. [2 ]
Kumagai M. [3 ]
Mizuno H. [3 ]
Mori S. [3 ]
机构
[1] Promotion Division of Heavy Ion Facilities, Kanagawa Cancer Center, 1-1-2 Nakao, Asahi-ku, Yokohama
[2] Therapy-Level Dose Calibration Center, Association for Nuclear Technology in Medicine, 3-9-19 Kurosunadai, Inage-Ku
[3] Department of Accelerator Physics and Medical Physics, Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku
关键词
Cone-beam CT; CT number; Electron density; Heel effect; QA;
D O I
10.1007/s12194-012-0194-x
中图分类号
学科分类号
摘要
We evaluated the CT number accuracy in determining a CT calibration method for treatment planning by use of a 256 multi-slice CT (MSCT) scanner. An electron density phantom, which extends full length in the longitudinal direction, was scanned by the 256 MSCT scanner in a single rotation. We inserted four types of samples (air, 100 % ethanol, 40 wt% aqueous K2HPO 4, and water) into the phantom. The regions of interest were set for all image slices, and the average CT number was calculated in the transverse and longitudinal sections. For the transverse image direction, the CT number became lower toward the center of the phantom with almost all samples. The causes of these phenomena might be attributed to the effects of scattered radiation and those of beam hardening due to the high-atomic-number material (40 wt% aqueous K2HPO4). However, the phenomena were too complicated to allow us to determine their causes only from the present studies. Meanwhile, for increasing the accuracy of the CT number calibration, a single sample should be inserted, and this step should be repeated with different samples. For the longitudinal direction, the CT number for a 40 wt % aqueous K 2HPO4 sample increased by 30 HU from the anode to the cathode side due to variations in the X-ray energy caused by the heel effect. The caveat is that the CT number varies in the longitudinal direction when a CT scanner with a wide beam width is used. © 2012 Japanese Society of Radiological Technology and Japan Society of Medical Physics.
引用
收藏
页码:241 / 247
页数:6
相关论文
共 50 条
  • [41] Study on reconstructed image of 3D cone-beam CT scanner
    Nakamori, N
    Sudou, T
    Kanamori, H
    Endou, M
    Kusakabe, M
    PHYSICS OF MEDICAL IMAGING: MEDICAL IMAGING 1996, 1996, 2708 : 696 - 705
  • [42] Radiochromic film thickness correction with convergent cone-beam optical CT scanner
    Jordan, Kevin
    8TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2015, 573
  • [43] Organ Doses From Cone-Beam CT in Radiation Therapy
    Hyer, D.
    Hintenlang, D.
    MEDICAL PHYSICS, 2009, 36 (06) : 2437 - +
  • [44] Adaptive Radiation Therapy using Megavoltage Cone-Beam CT
    Morin, Olivier
    Gillis, Amy
    Aubin, Michele
    Aubry, Jean-Francois
    Chen, Josephine
    Chen, Hong
    Descovich, Martina
    Pouliot, Jean
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1780 - 1784
  • [45] Cone-beam CT for radiation therapy with reverse helical trajectory
    Cho, S.
    Pelizzari, C.
    Pan, X.
    MEDICAL PHYSICS, 2006, 33 (06) : 1984 - 1984
  • [46] Integration of cone-beam CT in stereotactic body radiation therapy
    Yin, Fang-Fang
    Wang, Zhiheng
    Yoo, Sua
    Wu, Q. Jackie
    Kirkpatrick, John
    Larrier, Nicole
    Meyer, Jeffrey
    Willett, Christopher G.
    Marks, Lawrence B.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2008, 7 (02) : 133 - 139
  • [47] Cone-beam CT dose and imaging performance evaluation with a modular, multipurpose phantom
    Siewerdsen, J. H.
    Uneri, A.
    Hernandez, A. M.
    Burkett, G. W.
    Boone, J. M.
    MEDICAL PHYSICS, 2020, 47 (02) : 467 - 479
  • [48] Quantitative Assessment of CT Number Variation Induced by Respiratory Motion Artifacts in CT and Cone-Beam CT
    Jackson, S.
    Ahmad, S.
    Ali, I.
    MEDICAL PHYSICS, 2012, 39 (06) : 3683 - 3683
  • [50] Strategic use of cone-beam CT in modern spine surgery
    Chang, Chih-Chang
    Fay, Li-Yu
    Wu, Jau-Ching
    Chang, Peng-Yuan
    Tu, Tsung-Hsi
    Cheng, Henrich
    Huang, Wen-Cheng
    JOURNAL OF NEUROSURGERY-SPINE, 2017, 26 (04) : 544 - 545