Accuracy of pulse oximetry in the intensive care unit

被引:0
|
作者
A. Louw
C. Cracco
C. Cerf
A. Harf
P. Duvaldestin
F. Lemaire
L. Brochard
机构
[1] Anesthesiology Department and Surgical Intensive Care Unit,
[2] Henri Mondor Hospital,undefined
[3] Assistance Publique-Hôpitaux de Paris,undefined
[4] University Paris XII,undefined
[5] Créteil,undefined
[6] France,undefined
[7] Medical Intensive Care Unit,undefined
[8] Henri Mondor Hospital,undefined
[9] Assistance Publique-Hôpitaux de Paris,undefined
[10] University Paris XII,undefined
[11] Créteil,undefined
[12] France,undefined
[13] Physiology Department,undefined
[14] Henri Mondor Hospital,undefined
[15] Assistance Publique-Hôpitaux de Paris,undefined
[16] University Paris XII,undefined
[17] Créteil,undefined
[18] France,undefined
来源
Intensive Care Medicine | 2001年 / 27卷
关键词
Pulse oximetry Monitoring Oxygen saturation Intensive care;
D O I
暂无
中图分类号
学科分类号
摘要
Objective: Pulse oximetry (SpO2) is a standard monitoring device in intensive care units (ICUs), currently used to guide therapeutic interventions. Few studies have evaluated the accuracy of SpO2 in critically ill patients. Our objective was to compare pulse oximetry with arterial oxygen saturation (SaO2) in such patients, and to examine the effect of several factors on this relationship. Design: Observational prospective study. Setting: A 26-bed medical ICU in a university hospital. Patients: One hundred two consecutive patients admitted to the ICU in whom one or serial arterial blood gas analyses (ABGs) were performed and a reliable pulse oximeter signal was present. Interventions: For each ABG, we collected SaO2, SpO2, the type of pulse oximeter, the mode of ventilation and requirement for vasoactive drugs. Measurements and results: Three hundred twenty-three data points were collected. The mean difference between SpO2 and SaO2 was –0.02% and standard deviation of the differences was 2.1%. From one sample to another, the fluctuations in SpO2 to arterial saturation difference indicated that SaO2 could not be reliably predicted from SpO2 after a single ABG. Subgroup analysis showed that the accuracy of SpO2 appeared to be influenced by the type of oximeter, the presence of hypoxemia and the requirement for vasoactive drugs. Finally, high SpO2 thresholds were necessary to detect significant hypoxemia with good sensitivity. Conclusion: Large SpO2 to SaO2 differences may occur in critically ill patients with poor reproducibility of SpO2. A SpO2 above 94% appears necessary to ensure a SaO2 of 90%.
引用
收藏
页码:1606 / 1613
页数:7
相关论文
共 50 条
  • [41] Evaluating the Accuracy of Off-Label Placement of Pulse Oximetry Sensors in Comparison to On-Label Placement in the Adult Cardiac Intensive Care Unit Patient Population
    Hlavin, Danielle
    Bosma, Grace N.
    Bolt, Matthew A.
    Sammel, Mary D.
    Seyller, Nicole
    Varty, Maureen
    DIMENSIONS OF CRITICAL CARE NURSING, 2024, 43 (04) : 176 - 183
  • [42] QUALITY-CONTROL OF PULSE OXIMETRY IN NEONATAL INTENSIVE-CARE
    BENNETT, HJ
    BIEN, C
    METZGER, G
    KENNY, M
    CLINICAL CHEMISTRY, 1990, 36 (06) : 1007 - 1007
  • [43] Diagnostic accuracy in the medical intensive care unit
    M Podbregar
    G Voga
    B Krivec
    R Skale
    R Parežnik
    L Gabršček
    Critical Care, 5 (Suppl 1):
  • [44] PULSE-OXIMETRY IN INTENSIVE CARE: HAZARD WARNING OR POTENTIAL HAZARD?
    Goodall, J. R.
    Allan, W. B. D.
    INTENSIVE CARE MEDICINE, 2009, 35 : 269 - 269
  • [45] PULSE OXIMETRY IN NEONATAL INTENSIVE-CARE - GUIDELINES FOR ROUTINE USE
    REYNOLDS, GJ
    YU, VYH
    AUSTRALIAN PAEDIATRIC JOURNAL, 1987, 23 (06): : 375 - 375
  • [46] Working accuracy of pulse oximetry in COVID-19 patients stepping down from intensive care: a clinical evaluation
    Philip, Keir Elmslie James
    Bennett, Benjamin
    Fuller, Silas
    Lonergan, Bradley
    McFadyen, Charles
    Burns, Janis
    Tidswell, Robert
    Vlachou, Aikaterini
    BMJ OPEN RESPIRATORY RESEARCH, 2020, 7 (01)
  • [47] Analysis Pulse oximetry in primary care: factors affecting accuracy and interpretation
    Silverston, Paul
    Ferrari, Marco
    Quaresima, Valentina
    BRITISH JOURNAL OF GENERAL PRACTICE, 2022, 72 (716): : 132 - 133
  • [48] A two centre observational study of simultaneous pulse oximetry and arterial oxygen saturation recordings in intensive care unit patients
    Ebmeier, S. J.
    Barker, M.
    Bacon, M.
    Beasley, R. C.
    Bellomo, R.
    Chong, C. Knee
    Eastwood, G. M.
    Gilchrist, J.
    Kagaya, H.
    Pilcher, J.
    Reddy, S. K.
    Ridgeon, E.
    Sarma, N.
    Spragas, S.
    Tanaka, A.
    Tweedie, M.
    Weatherall, M.
    Young, P. J.
    ANAESTHESIA AND INTENSIVE CARE, 2018, 46 (03) : 297 - 303
  • [49] Impact of Pulse Oximetry Surveillance on Rescue Events and Intensive Care Unit Transfers A Before-and-After Concurrence Study
    Taenzer, Andreas H.
    Pyke, Joshua B.
    McGrath, Susan P.
    Blike, George T.
    ANESTHESIOLOGY, 2010, 112 (02) : 282 - 287
  • [50] PULSE OXIMETRY AND POSTOPERATIVE HYPOTHERMIA - AN EVALUATION OF THE NELLCOR N-100 IN A CARDIAC SURGICAL INTENSIVE-CARE UNIT
    GABRIELCZYK, MR
    BUIST, RJ
    ANAESTHESIA, 1988, 43 (05) : 402 - 404