Accuracy of pulse oximetry in the intensive care unit

被引:0
|
作者
A. Louw
C. Cracco
C. Cerf
A. Harf
P. Duvaldestin
F. Lemaire
L. Brochard
机构
[1] Anesthesiology Department and Surgical Intensive Care Unit,
[2] Henri Mondor Hospital,undefined
[3] Assistance Publique-Hôpitaux de Paris,undefined
[4] University Paris XII,undefined
[5] Créteil,undefined
[6] France,undefined
[7] Medical Intensive Care Unit,undefined
[8] Henri Mondor Hospital,undefined
[9] Assistance Publique-Hôpitaux de Paris,undefined
[10] University Paris XII,undefined
[11] Créteil,undefined
[12] France,undefined
[13] Physiology Department,undefined
[14] Henri Mondor Hospital,undefined
[15] Assistance Publique-Hôpitaux de Paris,undefined
[16] University Paris XII,undefined
[17] Créteil,undefined
[18] France,undefined
来源
Intensive Care Medicine | 2001年 / 27卷
关键词
Pulse oximetry Monitoring Oxygen saturation Intensive care;
D O I
暂无
中图分类号
学科分类号
摘要
Objective: Pulse oximetry (SpO2) is a standard monitoring device in intensive care units (ICUs), currently used to guide therapeutic interventions. Few studies have evaluated the accuracy of SpO2 in critically ill patients. Our objective was to compare pulse oximetry with arterial oxygen saturation (SaO2) in such patients, and to examine the effect of several factors on this relationship. Design: Observational prospective study. Setting: A 26-bed medical ICU in a university hospital. Patients: One hundred two consecutive patients admitted to the ICU in whom one or serial arterial blood gas analyses (ABGs) were performed and a reliable pulse oximeter signal was present. Interventions: For each ABG, we collected SaO2, SpO2, the type of pulse oximeter, the mode of ventilation and requirement for vasoactive drugs. Measurements and results: Three hundred twenty-three data points were collected. The mean difference between SpO2 and SaO2 was –0.02% and standard deviation of the differences was 2.1%. From one sample to another, the fluctuations in SpO2 to arterial saturation difference indicated that SaO2 could not be reliably predicted from SpO2 after a single ABG. Subgroup analysis showed that the accuracy of SpO2 appeared to be influenced by the type of oximeter, the presence of hypoxemia and the requirement for vasoactive drugs. Finally, high SpO2 thresholds were necessary to detect significant hypoxemia with good sensitivity. Conclusion: Large SpO2 to SaO2 differences may occur in critically ill patients with poor reproducibility of SpO2. A SpO2 above 94% appears necessary to ensure a SaO2 of 90%.
引用
收藏
页码:1606 / 1613
页数:7
相关论文
共 50 条
  • [31] Poor Agreement between Respiratory Variations in Pulse Oximetry Photoplethysmographic Waveform Amplitude and Pulse Pressure in Intensive Care Unit Patients
    Landsverk, Svein Aslak
    Hoiseth, Lars O.
    Kvandal, Per
    Hisdal, Jonny
    Skare, Oivind
    Kirkeboen, Knut A.
    ANESTHESIOLOGY, 2008, 109 (05) : 849 - 855
  • [32] Skin Pigmentation and Pulse Oximeter Accuracy in the Intensive Care Unit: A Pilot Prospective Study
    Fawzy, Ashraf
    Ali, Harith
    Dziedzic, Peter H.
    Potu, Niteesh
    Calvillo, Eusebia
    Golden, Sherita H.
    Iwashyna, Theodore J.
    Suarez, Jose I.
    Hager, David N.
    Garibaldi, Brian T.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2024, 210 (03) : 355 - 358
  • [33] Comparative evaluation of accuracy of pulse oximeters and factors affecting their performance in a tertiary care intensive care unit
    Singh, Anupam
    Singh, Malvinder
    EUROPEAN RESPIRATORY JOURNAL, 2017, 50
  • [34] Pulse Oximetry Waveform Variation Is Insensitive to Change in Volume Status of Ventilated Medical Intensive Care Unit Patients
    Rojas, J.
    Ribeiro, M.
    Maldonado, D.
    Quartin, A.
    Schein, R.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2009, 179
  • [35] Pulse oximetry screening to detect cyanotic congenital heart disease in sick neonates in a neonatal intensive care unit
    N. B. Mathur
    A. Gupta
    S. Kurien
    Indian Pediatrics, 2015, 52 : 769 - 772
  • [36] Pulse oximetry screening to detect cyanotic congenital heart disease in sick neonates in a neonatal intensive care unit
    Mathur, N. B.
    Gupta, A.
    Kurien, S.
    INDIAN PEDIATRICS, 2015, 52 (09) : 769 - 772
  • [37] Accuracy and Errors in Pulse Oximetry
    Rodriguez, J. A.
    Garrido, H.
    Martinez, A.
    Garcia, M. A.
    5TH LATIN AMERICAN CONGRESS ON BIOMEDICAL ENGINEERING (CLAIB 2011): SUSTAINABLE TECHNOLOGIES FOR THE HEALTH OF ALL, PTS 1 AND 2, 2013, 33 (1-2): : 758 - 761
  • [38] Accuracy of fetal pulse oximetry
    Luttkus, AK
    Lübke, M
    Büscher, U
    Porath, M
    Dudenhausen, JW
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2002, 81 (05) : 417 - 423
  • [39] Accuracy of Pulse Oximetry in Children
    Ross, Patrick A.
    Newth, Christopher J. L.
    Khemani, Robinder G.
    PEDIATRICS, 2014, 133 (01) : 22 - 29
  • [40] Pocket Pulse Oximetry Versus Standard Pulse Oximetry: Accuracy and Precision
    da Costa, Joao Cordeiro
    Roque, Ana
    Faustino, Paula
    Lima, Ricardo
    Viveiros, Filipa
    Guimaraes, Miguel
    CHEST, 2014, 145 (03)