A two centre observational study of simultaneous pulse oximetry and arterial oxygen saturation recordings in intensive care unit patients

被引:45
|
作者
Ebmeier, S. J. [1 ]
Barker, M. [2 ]
Bacon, M. [1 ]
Beasley, R. C. [1 ]
Bellomo, R. [2 ]
Chong, C. Knee [2 ]
Eastwood, G. M. [2 ]
Gilchrist, J. [1 ]
Kagaya, H. [3 ]
Pilcher, J. [1 ]
Reddy, S. K. [1 ]
Ridgeon, E. [1 ]
Sarma, N. [1 ]
Spragas, S. [2 ]
Tanaka, A. [2 ]
Tweedie, M. [3 ]
Weatherall, M. [4 ]
Young, P. J. [1 ,5 ]
机构
[1] Med Res Inst New Zealand, Wellington, New Zealand
[2] Austin Hosp, Dept Intens Care, Melbourne, Vic, Australia
[3] Austin Hosp, Intens Care Unit, Melbourne, Vic, Australia
[4] Univ Otago, Wellington Sch Med, Wellington, New Zealand
[5] Wellington Reg Hosp, Intens Care Unit, Wellington, New Zealand
关键词
pulse oximetry; monitoring: oxygen saturation tones; intensive care medicine; monitoring; CRITICALLY-ILL; ACCURACY; HYPEROXIA;
D O I
10.1177/0310057X1804600307
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The influence of variables that might affect the accuracy of pulse oximetry (SpO(2)) recordings in critically ill patients is not well established. We sought to describe the relationship between paired SpO(2)/SaO(2) (oxygen saturation via arterial blood gas analysis) in adult intensive care unit (ICU) patients and to describe the diagnostic performance of SpO(2) in detecting low SaO(2) and PaO2. A paired SpO(2)/SaO(2) measurement was obtained from 404 adults in ICU. Measurements were used to calculate bias, precision, and limits of agreement. Associations between bias and variables including vasopressor and inotrope use, capillary refill time, hand temperature, pulse pressure, body temperature, oximeter model, and skin colour were estimated. There was no overall statistically significant bias in paired SpO(2)/SaO(2) measurements; observed limits of agreement were +/-4.4%. However, body temperature, oximeter model, and skin colour, were statistically significantly associated with the degree of bias. SpO(2) <89% had a sensitivity of 3/7 (42.9%; 95% confidence intervals, CI, 9.9% to 81.6%) and a specificity of 344/384 (89.6%; 95% CI 86.1% to 92.5%) for detecting SaO(2) <89%. The absence of statistically significant bias in paired SpO(2)/SaO(2) in adult ICU patients provides support for the use of pulse oximetry to titrate oxygen therapy. However, SpO(2) recordings alone should be used cautiously when SaO(2) recordings of 4.4% higher or lower than the observed SpO(2) would be of concern. A range of variables relevant to the critically ill had little or no effect on bias.
引用
收藏
页码:297 / 303
页数:7
相关论文
共 50 条
  • [1] A two centre observational study of simultaneous pulse oximetry and arterial oxygen saturation recordings in intensive care patients (vol 46, pg 297, 2018)
    Ebmeier, S. J.
    Barker, M.
    Bacon, M.
    Beasley, R. C.
    Bellomo, R.
    Chong, C. Knee
    Eastwood, G. M.
    Gilchrist, J.
    Kagaya, H.
    Pilcher, J.
    Reddy, S. K.
    Ridgeon, E.
    Sarma, N.
    Spragas, S.
    Tanaka, A.
    Tweedie, M.
    Weatherall, M.
    Young, P. J.
    ANAESTHESIA AND INTENSIVE CARE, 2018, 46 (04) : 432 - 432
  • [2] Performance of popular pulse oximeters compared with simultaneous arterial oxygen saturation or clinical-grade pulse oximetry: a cross-sectional validation study in intensive care patients
    Harskamp, Ralf E.
    Bekker, Luuk
    Himmelreich, Jelle C. L.
    De Clercq, Lukas
    Karregat, Evert P. M.
    Sleeswijk, Mengalvio E.
    Lucassen, Wim A. M.
    BMJ OPEN RESPIRATORY RESEARCH, 2021, 8 (01)
  • [3] COMPARATIVE ACCURACY OF PULSE OXIMETRY AND TRANSCUTANEOUS OXYGEN IN ASSESSING ARTERIAL SATURATION IN PEDIATRIC INTENSIVE-CARE
    RUSSELL, RIR
    HELMS, PJ
    CRITICAL CARE MEDICINE, 1990, 18 (07) : 725 - 727
  • [4] RELIABILITY OF OXYGEN SATURATION BY PULSE OXIMETER TO DETECT HYPOXEMIA OF PATIENTS IN THE INTENSIVE CARE UNIT
    Kanai, R.
    Moriyama, K.
    Kohyama, T.
    Yorozu, T.
    ANESTHESIA AND ANALGESIA, 2012, 114
  • [5] Transesophageal versus surface pulse oximetry in intensive care unit patients
    Vicenzi, MN
    Gombotz, H
    Krenn, H
    Dorn, C
    Rehak, P
    CRITICAL CARE MEDICINE, 2000, 28 (07) : 2268 - 2270
  • [6] Accuracy and precision of pulse oximetry in ventilated patients of an intensive care unit
    Hinkelbein, J.
    Osika, A.
    Fiedler, F.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 : 179 - 179
  • [7] Comparative Analysis of Oxygen Saturation by Pulse Oximetry and Arterial Blood Gas in Hypoxemic Patients in a Tertiary Care Hospital
    Abraham, Elen A.
    Verma, Ghanshyam
    Arafat, Yasar
    Acharya, Sourya
    Kumar, Sunil
    Pantbalekundri, Nikhil
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (07)
  • [8] Accuracy of pulse oximetry in detection of oxygen saturation in patients admitted to the intensive care unit of heart surgery: comparison of finger, toe, forehead and earlobe probes
    Seifi, Sohila
    Khatony, Alireza
    Moradi, Gholamreza
    Abdi, Alireza
    Najafi, Farid
    BMC NURSING, 2018, 17
  • [9] Accuracy of pulse oximetry in detection of oxygen saturation in patients admitted to the intensive care unit of heart surgery: comparison of finger, toe, forehead and earlobe probes
    Sohila Seifi
    Alireza Khatony
    Gholamreza Moradi
    Alireza Abdi
    Farid Najafi
    BMC Nursing, 17
  • [10] STUDY ON PULSE OXIMETRY OXYGEN SATURATION LEVEL AND PARTIAL PRESSURE OF OXYGEN IN ARTERIAL BLOOD IN HOSPITALIZED NEONATE
    Das, J. C.
    Shahidullah, M.
    Khanam, S. T.
    Hafez, M. A.
    INTENSIVE CARE MEDICINE, 2013, 39 : S135 - S136