A two centre observational study of simultaneous pulse oximetry and arterial oxygen saturation recordings in intensive care unit patients
被引:45
|
作者:
Ebmeier, S. J.
论文数: 0引用数: 0
h-index: 0
机构:
Med Res Inst New Zealand, Wellington, New ZealandMed Res Inst New Zealand, Wellington, New Zealand
Ebmeier, S. J.
[1
]
Barker, M.
论文数: 0引用数: 0
h-index: 0
机构:
Austin Hosp, Dept Intens Care, Melbourne, Vic, AustraliaMed Res Inst New Zealand, Wellington, New Zealand
Barker, M.
[2
]
Bacon, M.
论文数: 0引用数: 0
h-index: 0
机构:
Med Res Inst New Zealand, Wellington, New ZealandMed Res Inst New Zealand, Wellington, New Zealand
Bacon, M.
[1
]
Beasley, R. C.
论文数: 0引用数: 0
h-index: 0
机构:
Med Res Inst New Zealand, Wellington, New ZealandMed Res Inst New Zealand, Wellington, New Zealand
Beasley, R. C.
[1
]
Bellomo, R.
论文数: 0引用数: 0
h-index: 0
机构:
Austin Hosp, Dept Intens Care, Melbourne, Vic, AustraliaMed Res Inst New Zealand, Wellington, New Zealand
Bellomo, R.
[2
]
Chong, C. Knee
论文数: 0引用数: 0
h-index: 0
机构:
Austin Hosp, Dept Intens Care, Melbourne, Vic, AustraliaMed Res Inst New Zealand, Wellington, New Zealand
Chong, C. Knee
[2
]
Eastwood, G. M.
论文数: 0引用数: 0
h-index: 0
机构:
Austin Hosp, Dept Intens Care, Melbourne, Vic, AustraliaMed Res Inst New Zealand, Wellington, New Zealand
Eastwood, G. M.
[2
]
Gilchrist, J.
论文数: 0引用数: 0
h-index: 0
机构:
Med Res Inst New Zealand, Wellington, New ZealandMed Res Inst New Zealand, Wellington, New Zealand
Gilchrist, J.
[1
]
Kagaya, H.
论文数: 0引用数: 0
h-index: 0
机构:
Austin Hosp, Intens Care Unit, Melbourne, Vic, AustraliaMed Res Inst New Zealand, Wellington, New Zealand
Kagaya, H.
[3
]
Pilcher, J.
论文数: 0引用数: 0
h-index: 0
机构:
Med Res Inst New Zealand, Wellington, New ZealandMed Res Inst New Zealand, Wellington, New Zealand
Pilcher, J.
[1
]
Reddy, S. K.
论文数: 0引用数: 0
h-index: 0
机构:
Med Res Inst New Zealand, Wellington, New ZealandMed Res Inst New Zealand, Wellington, New Zealand
Reddy, S. K.
[1
]
Ridgeon, E.
论文数: 0引用数: 0
h-index: 0
机构:
Med Res Inst New Zealand, Wellington, New ZealandMed Res Inst New Zealand, Wellington, New Zealand
Ridgeon, E.
[1
]
Sarma, N.
论文数: 0引用数: 0
h-index: 0
机构:
Med Res Inst New Zealand, Wellington, New ZealandMed Res Inst New Zealand, Wellington, New Zealand
Sarma, N.
[1
]
Spragas, S.
论文数: 0引用数: 0
h-index: 0
机构:
Austin Hosp, Dept Intens Care, Melbourne, Vic, AustraliaMed Res Inst New Zealand, Wellington, New Zealand
Spragas, S.
[2
]
Tanaka, A.
论文数: 0引用数: 0
h-index: 0
机构:
Austin Hosp, Dept Intens Care, Melbourne, Vic, AustraliaMed Res Inst New Zealand, Wellington, New Zealand
Tanaka, A.
[2
]
Tweedie, M.
论文数: 0引用数: 0
h-index: 0
机构:
Austin Hosp, Intens Care Unit, Melbourne, Vic, AustraliaMed Res Inst New Zealand, Wellington, New Zealand
Tweedie, M.
[3
]
Weatherall, M.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Otago, Wellington Sch Med, Wellington, New ZealandMed Res Inst New Zealand, Wellington, New Zealand
Weatherall, M.
[4
]
Young, P. J.
论文数: 0引用数: 0
h-index: 0
机构:
Med Res Inst New Zealand, Wellington, New Zealand
Wellington Reg Hosp, Intens Care Unit, Wellington, New ZealandMed Res Inst New Zealand, Wellington, New Zealand
Young, P. J.
[1
,5
]
机构:
[1] Med Res Inst New Zealand, Wellington, New Zealand
[2] Austin Hosp, Dept Intens Care, Melbourne, Vic, Australia
[3] Austin Hosp, Intens Care Unit, Melbourne, Vic, Australia
[4] Univ Otago, Wellington Sch Med, Wellington, New Zealand
[5] Wellington Reg Hosp, Intens Care Unit, Wellington, New Zealand
The influence of variables that might affect the accuracy of pulse oximetry (SpO(2)) recordings in critically ill patients is not well established. We sought to describe the relationship between paired SpO(2)/SaO(2) (oxygen saturation via arterial blood gas analysis) in adult intensive care unit (ICU) patients and to describe the diagnostic performance of SpO(2) in detecting low SaO(2) and PaO2. A paired SpO(2)/SaO(2) measurement was obtained from 404 adults in ICU. Measurements were used to calculate bias, precision, and limits of agreement. Associations between bias and variables including vasopressor and inotrope use, capillary refill time, hand temperature, pulse pressure, body temperature, oximeter model, and skin colour were estimated. There was no overall statistically significant bias in paired SpO(2)/SaO(2) measurements; observed limits of agreement were +/-4.4%. However, body temperature, oximeter model, and skin colour, were statistically significantly associated with the degree of bias. SpO(2) <89% had a sensitivity of 3/7 (42.9%; 95% confidence intervals, CI, 9.9% to 81.6%) and a specificity of 344/384 (89.6%; 95% CI 86.1% to 92.5%) for detecting SaO(2) <89%. The absence of statistically significant bias in paired SpO(2)/SaO(2) in adult ICU patients provides support for the use of pulse oximetry to titrate oxygen therapy. However, SpO(2) recordings alone should be used cautiously when SaO(2) recordings of 4.4% higher or lower than the observed SpO(2) would be of concern. A range of variables relevant to the critically ill had little or no effect on bias.
机构:
Kyorin Univ, Anesthesiol, Sch Med, Tokyo, Japan
Saiseikai Yokohamashi Tobu Hosp, Intens Care Med, Yokohama, Kanagawa, JapanKyorin Univ, Anesthesiol, Sch Med, Tokyo, Japan
Kanai, R.
Moriyama, K.
论文数: 0引用数: 0
h-index: 0
机构:
Kyorin Univ, Anesthesiol, Sch Med, Tokyo, JapanKyorin Univ, Anesthesiol, Sch Med, Tokyo, Japan
Moriyama, K.
Kohyama, T.
论文数: 0引用数: 0
h-index: 0
机构:
Kyorin Univ, Anesthesiol, Sch Med, Tokyo, Japan
Saiseikai Yokohamashi Tobu Hosp, Intens Care Med, Yokohama, Kanagawa, JapanKyorin Univ, Anesthesiol, Sch Med, Tokyo, Japan
Kohyama, T.
Yorozu, T.
论文数: 0引用数: 0
h-index: 0
机构:
Kyorin Univ, Anesthesiol, Sch Med, Tokyo, JapanKyorin Univ, Anesthesiol, Sch Med, Tokyo, Japan