A two centre observational study of simultaneous pulse oximetry and arterial oxygen saturation recordings in intensive care unit patients

被引:45
|
作者
Ebmeier, S. J. [1 ]
Barker, M. [2 ]
Bacon, M. [1 ]
Beasley, R. C. [1 ]
Bellomo, R. [2 ]
Chong, C. Knee [2 ]
Eastwood, G. M. [2 ]
Gilchrist, J. [1 ]
Kagaya, H. [3 ]
Pilcher, J. [1 ]
Reddy, S. K. [1 ]
Ridgeon, E. [1 ]
Sarma, N. [1 ]
Spragas, S. [2 ]
Tanaka, A. [2 ]
Tweedie, M. [3 ]
Weatherall, M. [4 ]
Young, P. J. [1 ,5 ]
机构
[1] Med Res Inst New Zealand, Wellington, New Zealand
[2] Austin Hosp, Dept Intens Care, Melbourne, Vic, Australia
[3] Austin Hosp, Intens Care Unit, Melbourne, Vic, Australia
[4] Univ Otago, Wellington Sch Med, Wellington, New Zealand
[5] Wellington Reg Hosp, Intens Care Unit, Wellington, New Zealand
关键词
pulse oximetry; monitoring: oxygen saturation tones; intensive care medicine; monitoring; CRITICALLY-ILL; ACCURACY; HYPEROXIA;
D O I
10.1177/0310057X1804600307
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The influence of variables that might affect the accuracy of pulse oximetry (SpO(2)) recordings in critically ill patients is not well established. We sought to describe the relationship between paired SpO(2)/SaO(2) (oxygen saturation via arterial blood gas analysis) in adult intensive care unit (ICU) patients and to describe the diagnostic performance of SpO(2) in detecting low SaO(2) and PaO2. A paired SpO(2)/SaO(2) measurement was obtained from 404 adults in ICU. Measurements were used to calculate bias, precision, and limits of agreement. Associations between bias and variables including vasopressor and inotrope use, capillary refill time, hand temperature, pulse pressure, body temperature, oximeter model, and skin colour were estimated. There was no overall statistically significant bias in paired SpO(2)/SaO(2) measurements; observed limits of agreement were +/-4.4%. However, body temperature, oximeter model, and skin colour, were statistically significantly associated with the degree of bias. SpO(2) <89% had a sensitivity of 3/7 (42.9%; 95% confidence intervals, CI, 9.9% to 81.6%) and a specificity of 344/384 (89.6%; 95% CI 86.1% to 92.5%) for detecting SaO(2) <89%. The absence of statistically significant bias in paired SpO(2)/SaO(2) in adult ICU patients provides support for the use of pulse oximetry to titrate oxygen therapy. However, SpO(2) recordings alone should be used cautiously when SaO(2) recordings of 4.4% higher or lower than the observed SpO(2) would be of concern. A range of variables relevant to the critically ill had little or no effect on bias.
引用
收藏
页码:297 / 303
页数:7
相关论文
共 50 条
  • [21] Two-Dimensional-Strain Echocardiography in Intensive Care Unit Patients: A Prospective, Observational Study
    Nafati, Cyril
    Lancon, Victor
    Blasco, Valery
    Zieleskiewicz, Laurent
    Harti, Karim
    Wiramus, Sandrine
    Kelway, Charlotte
    Reydellet, Laurent
    Antonini, Francois
    Albanese, Jacques
    Leone, Marc
    JOURNAL OF CLINICAL ULTRASOUND, 2016, 44 (06) : 368 - 374
  • [22] Pulse Oximetry Saturation (Spo2) Monitoring in the Neonatal Intensive Care Unit (NICU): The Challenge for Providers A Systematic Review
    Falsaperla, Raffaele
    Giacchi, Valentina
    Saporito, Marco Andrea Nicola
    Pavone, Piero
    Puglisi, Federica
    Ruggieri, Martino
    ADVANCES IN NEONATAL CARE, 2022, 22 (03) : 231 - 238
  • [23] Regional cerebral tissue oxygen saturation changes following blood transfusion in neuro-intensive care unit patients-a pilot observational study
    Muthuchellappan, R.
    Shaikh, N. A.
    Surve, R. M.
    Ganne, U. R. S.
    Philip, M.
    TRANSFUSION MEDICINE, 2018, 28 (04) : 304 - 309
  • [24] The clinical use of two new generation pulse oximetry (SpO2,) devices for patients in the neonatal intensive care unit (NICU)
    Workei, FA
    Rais-Bahrami, K
    Short, BL
    PEDIATRIC RESEARCH, 2004, 55 (04) : 562A - 562A
  • [25] A Prospective Observational Study Comparing Oxygen Saturation/Fraction of Inspired Oxygen Ratio with Partial Pressure of Oxygen in Arterial Blood/Fraction of Inspired Oxygen Ratio among Critically Ill Patients Requiring Different Modes of Oxygen Supplementation in Intensive Care Unit
    Alur, T. Rakesh
    Iyer, Shivakumar S.
    Shah, Jignesh N.
    Kulkarni, Sampada
    Jedge, Prashant
    Patil, Vishwanath
    INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2024, 28 (03) : 251 - 255
  • [26] Independent Component Analysis Applied to Pulse Oximetry in the Estimation of the Arterial Oxygen Saturation (SpO2) - a Comparative Study
    Jensen, Thomas
    Duun, Sune
    Larsen, Jan
    Haahr, Rasmus G.
    Toft, Mette H.
    Belhage, Bo
    Thomsen, Erik V.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 4039 - +
  • [27] Poor Agreement between Respiratory Variations in Pulse Oximetry Photoplethysmographic Waveform Amplitude and Pulse Pressure in Intensive Care Unit Patients
    Landsverk, Svein Aslak
    Hoiseth, Lars O.
    Kvandal, Per
    Hisdal, Jonny
    Skare, Oivind
    Kirkeboen, Knut A.
    ANESTHESIOLOGY, 2008, 109 (05) : 849 - 855
  • [28] A pilot study of pharyngeal pulse oximetry with the laryngeal mask airway:: A comparison with finger oximetry and arterial saturation measurements in healthy anesthetized patients
    Keller, C
    Brimacombe, J
    Agrò, F
    Margreiter, J
    ANESTHESIA AND ANALGESIA, 2000, 90 (02): : 440 - 444
  • [29] A single-centre observational study of delayed defaecation in brain-injured patients in an adult intensive care unit
    McConnochie, Rachael
    O'Brien, Anthony
    Parke, Rachael
    AUSTRALIAN CRITICAL CARE, 2024, 37 (02) : 244 - 250
  • [30] Pulse Oximetry Waveform Variation Is Insensitive to Change in Volume Status of Ventilated Medical Intensive Care Unit Patients
    Rojas, J.
    Ribeiro, M.
    Maldonado, D.
    Quartin, A.
    Schein, R.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2009, 179