Early migration characteristics of a hydroxyapatite-coated femoral stem: an RSA study

被引:0
|
作者
David Campbell
Graham Mercer
Kjell G. Nilsson
Vanessa Wells
John R. Field
Stuart A. Callary
机构
[1] Repatriation General Hospital,Orthopaedic Unit
[2] Umeå University Hospital,Department of Orthopaedics
[3] Flinders University,CORe: Comparative Orthopaedic Research Surgical Facility
[4] University of Adelaide,Discipline of Orthopaedics and Trauma
[5] Royal Adelaide Hospital,Department of Orthopaedics and Trauma
来源
关键词
Stem Rotation; Early Migration; Stem Subsidence; Cementless Stem; Radiostereometric Analysis;
D O I
暂无
中图分类号
学科分类号
摘要
Measurement of early stem subsidence can be used to predict the likelihood of long-term femoral component loosening and clinical failure. Data that examines the early migration pattern of clinically proven stems will provide clinicians with useful baseline data with which to compare new stem designs. This study was performed to evaluate the early migration pattern of a hydroxyapatite-coated press-fit femoral component that has been in use for over ten years. We enrolled 30 patients who underwent THA for osteoarthritis. The median age was 70 years (range, 55–80 years). Patients were clinically assessed using the Harris hip score. Radiostereometric analysis was used to evaluate stem migration at three to four days, six months, one year and two years. We observed a mean subsidence of 0.73 mm at six months, 0.62 mm at one year and 0.58 mm at two years and a mean retroversion of 1.82° at six months, 1.90° at one year and 1.59° at two years. This data suggests that subsidence is confined to the first six months after which there was no further subsidence. The results from this study can be compared with those from novel cementless stem designs to help predict the long-term outcome one may expect from new cementless stem designs.
引用
收藏
页码:483 / 488
页数:5
相关论文
共 50 条
  • [21] Clinical and radiological outcome of hydroxyapatite-coated femoral stem in revision hip arthroplasty
    T. Gosens
    E. J. van Langelaan
    International Orthopaedics, 2005, 29 : 219 - 223
  • [22] Clinical and radiological outcome of hydroxyapatite-coated femoral stem in revision hip arthroplasty
    Gosens, T
    van Langelaan, EJ
    INTERNATIONAL ORTHOPAEDICS, 2005, 29 (04) : 219 - 223
  • [23] Use of a hydroxyapatite-coated stem in patients with dorr Type C femoral bone
    Kelly, Stephen J.
    Robbins, Claire E.
    Bierbaum, Benjamin E.
    Bono, James V.
    Ward, Daniel M.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (465) : 112 - 116
  • [24] Migration and wear of a hydroxyapatite-coated hip prosthesis
    Onsten, I
    Carlsson, AS
    Sanzen, L
    Besjakov, J
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (01): : 85 - 91
  • [25] Osseointegration of a hydroxyapatite-coated stem in femoral neck fractures in the over-80 s
    Mathias Kirsch
    Hugo Kremer
    Camille Fabbri
    Pierre Capdevielle
    Florian Collignon
    Didier Mainard
    European Journal of Orthopaedic Surgery & Traumatology, 2024, 34 : 1535 - 1541
  • [26] Osseointegration of a hydroxyapatite-coated stem in femoral neck fractures in the over-80 s
    Kirsch, Mathias
    Kremer, Hugo
    Fabbri, Camille
    Capdevielle, Pierre
    Collignon, Florian
    Mainard, Didier
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2024, 34 (03): : 1535 - 1541
  • [27] Fixation of the fully hydroxyapatite-coated Corail stem implanted due to femoral neck fracture 38 patients followed for 2 years with RSA and DEXA
    von Schewelov, Thord
    Ahlborg, Henrik
    Sanzen, Lennart
    Besjakov, Jack
    Carlsson, Ake
    ACTA ORTHOPAEDICA, 2012, 83 (02) : 153 - 158
  • [28] HISTOLOGIC ANALYSIS OF A RETRIEVED HYDROXYAPATITE-COATED FEMORAL PROSTHESIS
    SOBALLE, K
    GOTFREDSEN, K
    BROCKSTEDTRASMUSSEN, H
    NIELSEN, PT
    RECHNAGEL, K
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1991, (272) : 255 - 258
  • [29] Modeling of bone around hydroxyapatite-coated femoral stems
    DAntonio, JA
    Township, M
    Capello, WN
    Manley, MT
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (08): : 1226 - 1234
  • [30] Osseointegration of a hydroxyapatite-coated multilayered mesh stem
    Kusakabe, H
    Sakamaki, T
    Nihei, K
    Oyama, Y
    Yanagimoto, S
    Ichimiya, M
    Kimura, J
    Toyama, Y
    BIOMATERIALS, 2004, 25 (15) : 2957 - 2969