Accuracy of an Automatic Patient-Positioning System Based on the Correlation of Two Edge Images in Radiotherapy

被引:0
|
作者
Myonggeun Yoon
Minho Cheong
Jinsung Kim
Dong Ho Shin
Sung Yong Park
Se Byeong Lee
机构
[1] National Cancer Center,Proton Therapy Center
[2] Samsung Medical Center,Department of Radiation Oncology
来源
关键词
Automated object detection; radiotherapy; digital image processing;
D O I
暂无
中图分类号
学科分类号
摘要
We have clinically evaluated the accuracy of an automatic patient-positioning system based on the image correlation of two edge images in radiotherapy. Ninety-six head & neck images from eight patients undergoing proton therapy were compared with a digitally reconstructed radiograph (DRR) of planning CT. Two edge images, a reference image and a test image, were extracted by applying a Canny edge detector algorithm to a DRR and a 2D X-ray image, respectively, of each patient before positioning. In a simulation using a humanoid phantom, performed to verify the effectiveness of the proposed method, no registration errors were observed for given ranges of rotation, pitch, and translation in the x, y, and z directions. For real patients, however, there were discrepancies between the automatic positioning method and manual positioning by physicians or technicians. Using edged head coronal- and sagittal-view images, the average differences in registration between these two methods for the x, y, and z directions were 0.11 cm, 0.09 cm and 0.11 cm, respectively, whereas the maximum discrepancies were 0.34 cm, 0.38 cm, and 0.50 cm, respectively. For rotation and pitch, the average registration errors were 0.95° and 1.00°, respectively, and the maximum errors were 3.6° and 2.3°, respectively. The proposed automatic patient-positioning system based on edge image comparison was relatively accurate for head and neck patients. However, image deformation during treatment may render the automatic method less accurate, since the test image many differ significantly from the reference image.
引用
收藏
页码:322 / 330
页数:8
相关论文
共 50 条
  • [1] Accuracy of an Automatic Patient-Positioning System Based on the Correlation of Two Edge Images in Radiotherapy
    Yoon, Myonggeun
    Cheong, Minho
    Kim, Jinsung
    Shin, Dong Ho
    Park, Sung Yong
    Lee, Se Byeong
    JOURNAL OF DIGITAL IMAGING, 2011, 24 (02) : 322 - 330
  • [2] Study of Automatic Patient Positioning System Based On the Correlation of Two Edge Images in Proton Therapy
    Yoon, M.
    Cheong, M.
    Kim, J.
    Shin, D.
    Kim, D.
    Lim, Y.
    Ahn, S.
    Lee, S.
    Park, S.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [3] Automatic portal image based patient positioning for radiotherapy
    Bloch, P
    Khamene, A
    Sauer, F
    Wein, W
    Maughan, R
    Svatos, M
    MEDICAL PHYSICS, 2004, 31 (06) : 1866 - 1866
  • [4] A dynamic compensation strategy to correct patient-positioning errors in conformal prostate radiotherapy
    Lauve, A. D.
    Siebers, J. V.
    Crimaldi, A. J.
    Hagan, M. P.
    Keall, P. J.
    MEDICAL PHYSICS, 2006, 33 (06) : 1879 - 1887
  • [5] Evaluating the setup accuracy of patient positioning and transfer system in radiotherapy
    Cheng, K. F.
    Mui, W. L.
    Yu, S. K.
    Cheung, K. Y.
    Hui, G.
    Yang, B. K.
    Chiu, G.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S135 - S135
  • [6] Patient positioning method based on binary image correlation between two edge images for proton-beam radiation therapy
    Sawada, A
    Yoda, K
    Numano, M
    Futami, Y
    Yamashita, H
    Murayama, S
    Tsugami, H
    MEDICAL PHYSICS, 2005, 32 (10) : 3106 - 3111
  • [7] Patient positioning accuracy with surface guided radiotherapy
    Mychko, D.
    Dziameshka, P.
    Zverava, A.
    Siamkousky, S.
    Shautsou, N.
    Chyrets, M.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S2022 - S2022
  • [8] Office-based laryngology: Technical and visual optimization by patient-positioning maneuvers
    Ghodke, Ameer
    Farquhar, Douglas R.
    Buckmire, Robert A.
    Shah, Rupali N.
    LARYNGOSCOPE, 2019, 129 (02): : 330 - 334
  • [9] Development and Accuracy Evaluation of Augmented Reality-based Patient Positioning System in Radiotherapy: A Phantom Study
    Tarutani, Kazuo
    Takaki, Haruyuki
    Igeta, Masataka
    Fujiwara, Masayuki
    Okamura, Ayako
    Horio, Futo
    Toudou, Yuki
    Nakajima, Satoshi
    Kagawa, Kazufumi
    Tanooka, Masao
    Yamakado, Koichiro
    IN VIVO, 2021, 35 (04): : 2081 - 2087
  • [10] Automatic DRR Enhancement for Patient Positioning in a Radiotherapy Treatment
    Verdu-Monedero, Rafael
    Larrey-Ruiz, Jorge
    Morales-Sanchez, Juan
    Luis Sancho-Gomez, Jose
    2009 PROCEEDINGS OF 6TH INTERNATIONAL SYMPOSIUM ON IMAGE AND SIGNAL PROCESSING AND ANALYSIS (ISPA 2009), 2009, : 127 - 132