Development and Accuracy Evaluation of Augmented Reality-based Patient Positioning System in Radiotherapy: A Phantom Study

被引:10
|
作者
Tarutani, Kazuo [1 ,2 ]
Takaki, Haruyuki [1 ]
Igeta, Masataka [3 ]
Fujiwara, Masayuki [1 ]
Okamura, Ayako [2 ]
Horio, Futo [4 ]
Toudou, Yuki [2 ]
Nakajima, Satoshi [2 ]
Kagawa, Kazufumi [2 ]
Tanooka, Masao [5 ]
Yamakado, Koichiro [1 ]
机构
[1] Hyogo Coll Med, Dept Radiol, 1-1 Mukogawa Cho, Nishinomiya, Hyogo 6638501, Japan
[2] Kansai Rousai Hosp, Japan Org Occupat Hlth & Safety, Amagasaki, Hyogo, Japan
[3] Hyogo Coll Med, Dept Biostat, Nishinomiya, Hyogo, Japan
[4] Kobe Digital Labo Inc, Kobe, Hyogo, Japan
[5] Takarazuka City Hosp, Dept Radiotherapy, Takarazuka, Hyogo, Japan
来源
IN VIVO | 2021年 / 35卷 / 04期
关键词
Augmented reality; head mounted display system; image-guided radiotherapy; patient setup; HOLOLENS; SETUP;
D O I
10.21873/invivo.12477
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background/Aim: To develop and evaluate the accuracy of augmented reality (AR)-based patient positioning systems in radiotherapy. Materials and Methods: AR head-mounted displays (AR-HMDs), which virtually superimpose a three-dimensional (3D) image generated by the digital imaging and communications in medicine (DICOM) data, have been developed. The AR-based positioning feasibility was evaluated. Then, the setup errors of three translational axes directions and rotation angles between the AR and the conventional laser-based positioning were compared. Results: The AR-based pelvic phantom positioning was feasible. The setup errors of AR-based positioning were comparable to laser-based positioning in all translational axis directions and rotation angles. The time necessary for AR-based positioning was significantly longer than that for laser-based positioning (171.0 s vs. 47.5 s, p<0.001). Conclusion: AR-based positioning for radiotherapy was feasible, and showed comparable positioning errors to those of conventional line-based positioning; however, a markedly longer setup time was necessary.
引用
收藏
页码:2081 / 2087
页数:7
相关论文
共 50 条
  • [1] Development and Evaluation of a Virtual Reality-Based Radiotherapy Platform
    Sutherland, J.
    La Russa, D.
    MEDICAL PHYSICS, 2018, 45 (06) : E556 - E557
  • [2] Usability evaluation of augmented reality-based maintenance instruction system
    Wang, Chao-Hung
    Lo, Wei-Jen
    Wang, Mao-Jiun J.
    HUMAN FACTORS AND ERGONOMICS IN MANUFACTURING & SERVICE INDUSTRIES, 2022, 32 (03) : 239 - 255
  • [3] Usability evaluation of augmented reality-based maintenance instruction system
    Wang, Chao-Hung
    Lo, Wei-Jen
    Wang, Mao-Jiun J.
    Human Factors and Ergonomics In Manufacturing, 2022, 32 (03): : 239 - 255
  • [4] Evaluation of the Effectiveness of Augmented Reality-Based Teaching Material: The Solar System
    Durukan, Ummu Gulsum
    Guntepe, Ebru Turan
    Usta, Necla Donmez
    INTERNATIONAL JOURNAL OF HUMAN-COMPUTER INTERACTION, 2023, 39 (12) : 2542 - 2556
  • [5] The development and evaluation of an augmented reality-based armillary sphere for astronomical observation instruction
    Zhang, Jia
    Sung, Yao-Ting
    Hou, Huei-Tse
    Chang, Kuo-En
    COMPUTERS & EDUCATION, 2014, 73 : 178 - 188
  • [6] Feasibility evaluation of radiotherapy positioning system guided by augmented reality and point cloud registration
    Zhai, Shaozhuang
    Wei, Ziwen
    Wu, Xiaolong
    Xing, Ligang
    Yu, Jinming
    Qian, Junchao
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (04):
  • [7] Augmented Reality-based Interactive Typography Experience and Evaluation
    Li, Hong
    Applied Mathematics and Nonlinear Sciences, 2024, 9 (01)
  • [8] Augmented Reality-Based Home Interaction Layout and Evaluation
    Chen, Ningxin
    Lu, Zheng
    Yu, Xinhui
    Yang, Liuming
    Xu, Pengfei
    Fan, Yachun
    ADVANCES IN COMPUTER GRAPHICS, CGI 2022, 2022, 13443 : 395 - 406
  • [9] Development of an Augmented Reality-Based Game for Projectile Motion
    Chandrakar, Milan
    Bhagat, Kaushal Kumar
    PHYSICS TEACHER, 2020, 58 (09): : 668 - 669
  • [10] A novel surface imaging system for patient positioning and surveillance during radiotherapy A phantom study and clinical evaluation
    Stieler, F.
    Wenz, F.
    Shi, M.
    Lohr, F.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2013, 189 (11) : 938 - 944