Accuracy of an Automatic Patient-Positioning System Based on the Correlation of Two Edge Images in Radiotherapy

被引:0
|
作者
Myonggeun Yoon
Minho Cheong
Jinsung Kim
Dong Ho Shin
Sung Yong Park
Se Byeong Lee
机构
[1] National Cancer Center,Proton Therapy Center
[2] Samsung Medical Center,Department of Radiation Oncology
来源
关键词
Automated object detection; radiotherapy; digital image processing;
D O I
暂无
中图分类号
学科分类号
摘要
We have clinically evaluated the accuracy of an automatic patient-positioning system based on the image correlation of two edge images in radiotherapy. Ninety-six head & neck images from eight patients undergoing proton therapy were compared with a digitally reconstructed radiograph (DRR) of planning CT. Two edge images, a reference image and a test image, were extracted by applying a Canny edge detector algorithm to a DRR and a 2D X-ray image, respectively, of each patient before positioning. In a simulation using a humanoid phantom, performed to verify the effectiveness of the proposed method, no registration errors were observed for given ranges of rotation, pitch, and translation in the x, y, and z directions. For real patients, however, there were discrepancies between the automatic positioning method and manual positioning by physicians or technicians. Using edged head coronal- and sagittal-view images, the average differences in registration between these two methods for the x, y, and z directions were 0.11 cm, 0.09 cm and 0.11 cm, respectively, whereas the maximum discrepancies were 0.34 cm, 0.38 cm, and 0.50 cm, respectively. For rotation and pitch, the average registration errors were 0.95° and 1.00°, respectively, and the maximum errors were 3.6° and 2.3°, respectively. The proposed automatic patient-positioning system based on edge image comparison was relatively accurate for head and neck patients. However, image deformation during treatment may render the automatic method less accurate, since the test image many differ significantly from the reference image.
引用
收藏
页码:322 / 330
页数:8
相关论文
共 50 条
  • [21] Patient set-up in radiotherapy with video-based positioning system
    Tao, S
    Wu, A
    Wu, Y
    Chen, Y
    Zhang, J
    CLINICAL ONCOLOGY, 2006, 18 (04) : 363 - 366
  • [22] DRR and Portal Image Registration for Automatic Patient Positioning in Radiotherapy Treatment
    Ma Consuelo Bastida-Jumilla
    Jorge Larrey-Ruiz
    Rafael Verdú-Monedero
    Juan Morales-Sánchez
    José-Luis Sancho-Gómez
    Journal of Digital Imaging, 2011, 24 : 999 - 1009
  • [23] DRR and Portal Image Registration for Automatic Patient Positioning in Radiotherapy Treatment
    Consuelo Bastida-Jumilla, Ma
    Larrey-Ruiz, Jorge
    Verdu-Monedero, Rafael
    Morales-Sanchez, Juan
    Sancho-Gomez, Jose-Luis
    JOURNAL OF DIGITAL IMAGING, 2011, 24 (06) : 999 - 1009
  • [24] Preliminary Evaluation of Geometric Positioning Accuracy of C-SAR Images Based on Automatic Corner Reflectors
    Jiao, Yanan
    Zhang, Fengli
    Liu, Xiaochen
    Wang, Qi
    Huang, Qiqi
    Huang, Zhiwei
    REMOTE SENSING, 2023, 15 (19)
  • [25] Positioning accuracy of a new image-guided radiotherapy system
    Miyabe, Yuki
    Sawada, Akira
    Takayama, Kenji
    Kaneko, Shuji
    Mizowaki, Takashi
    Kokubo, Masaki
    Hiraoka, Masahiro
    MEDICAL PHYSICS, 2011, 38 (05) : 2535 - 2541
  • [26] Blurring Correction of Portal Images by 2D-Deconvolution, Providing Enhanced Accuracy of Radiotherapy Patient Positioning Verification
    Looe, H. K.
    Harder, D.
    Poppe, B.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [27] Accuracy of a photogrammetry-based patient positioning and monitoring system for radiation therapy
    Rogus, RD
    Stern, RL
    Kubo, HD
    MEDICAL PHYSICS, 1999, 26 (05) : 721 - 728
  • [28] An electromechanical, patient positioning system for head and neck radiotherapy
    Ostyn, Mark
    Dwyer, Thomas
    Miller, Matthew
    King, Paden
    Sacks, Rachel
    Cruikshank, Ross
    Rosario, Melvin
    Martinez, Daniel
    Kim, Siyong
    Yeo, Woon-Hong
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (18): : 7520 - 7531
  • [29] A comparative analysis of the accuracy of positioning techniques in automatic identification system
    Jiang, Yi
    Hu, Qing
    Yang, Dongkai
    ICIC Express Letters, 2015, 9 (01): : 81 - 86
  • [30] Automatic distortion measuring system with reticle positioning for enhanced accuracy
    Lin, Chern-Sheng
    Chang, Su-Chi
    Lay, Yun-Long
    Yeh, Mau-Shiun
    Lee, Chieh-Jen
    MEASUREMENT, 2008, 41 (09) : 960 - 969