A dynamic compensation strategy to correct patient-positioning errors in conformal prostate radiotherapy

被引:14
|
作者
Lauve, A. D. [1 ]
Siebers, J. V. [1 ]
Crimaldi, A. J. [1 ]
Hagan, M. P. [1 ]
Keall, P. J. [1 ]
机构
[1] Virginia Commonwealth Univ, Dept Radiat Oncol, Richmond, VA 23298 USA
关键词
dynamic compensation strategy; patient-positioning errors; prostate;
D O I
10.1118/1.2198967
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Traditionally, pretreatment detected patient-positioning errors have been corrected by repositioning the couch to align the patient to the treatment beam. We investigated an alternative strategy: aligning the beam to the patient by repositioning the dynamic multileaf collimator and adjusting the beam weights, termed dynamic compensation. The purpose of this Study was to determine the geometric range of positioning errors for which the dynamic compensation method is valid in prostate cancer patients treated with three-dimensional conformal radiotherapy. Twenty-five previously treated prostate cancer patients were replanned using a four-field technique to deliver 72 Gy to 95% of the planning target volume (PTV). Patient-positioning errors were introduced by shifting the patient reference frame with respect to the treatment isocenter. Thirty-six randomly selected isotropic displacements with magnitudes of 1.0, 2.0, 4.01 6.0, 8.0, and 10.0 cm were sampled for each patient, for a total of 5400 errors. Dynamic compensation was used to correct each of these errors by conforming the beam apertures to the new target position and adjusting the monitor units using inverse-square and off-axis factor corrections. The dynamic compensation plans were then compared with the original treatment plans via dose-volume histogram (DVH) analysis. Changes of more than 5% of the prescription dose, 3.6 Gy, were deemed significant. Compared with the original treatment plans, dynamic compensation produced small discrepancies in isodose distributions and DVH analyses. These differences increased with the magnitudes of the initial patient-positioning errors. Coverage of the PTV was excellent: D-95 and D-mean were not increased or decreased by more than 5% of the prescription dose, and D-5 was not decreased by more than 5% of the prescription dose for any of the 5400 simulated positioning errors. D-5 was increased by more than 5% of the prescription dose in only three of the 5400 positioning errors, all three occurring with a positioning error of 10.0 cm. Dose increases for adjacent organs at risk were more common. D-33 of the rectum and the periprostatic rectum was increased by more than 5% of the prescription dose in 235 (4.4%) and 212 (3.9%) of the 5400 positioning errors, respectively. D-10 of the right femoral head increased by more than 5% of the prescription dose in 444 (8.2%) positioning errors, and the degree of change was highly related to individual patient anatomy and simulation position. For the bladder D-20, there were three increases of more than 5% of the prescription dose. These data demonstrate the robustness of dynamic compensation for correction of patient-positioning errors in four-field conformal prostate radiotherapy, with minimal deviation from the original treatment plans even for errors greatly exceeding those commonly encountered in the clinic. Dynamic compensation can be performed remotely, thus eliminating errors that may result from unnecessary increases in treatment time or from secondary patient motion induced by couch motion during the repositioning process. Further, the ability of dynamic compensation to correct large positioning errors has implications for the accuracy necessary during the initial patient setup and, hence, patient throughput for prostate radiotherapy. (C) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:1879 / 1887
页数:9
相关论文
共 50 条
  • [1] Measurement of patient positioning errors in three-dimensional conformal radiotherapy of the prostate
    Hanley, J
    Lumley, MA
    Mageras, GS
    Sun, J
    Zelefsky, MJ
    Leibel, SA
    Fuks, Z
    Kutcher, GJ
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (02): : 435 - 444
  • [2] A Novel Patient-Positioning Device for Dynamic CT Myelography
    Callen, Andrew L.
    Wojcik, Rich
    Bojanowski, Michael
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2023, 44 (11) : 1352 - 1355
  • [3] A strategy to correct for intrafraction target translation in conformal prostate radiotherapy: Simulation results
    Keall, P. J.
    Lauve, A. D.
    Hagan, M. P.
    Siebers, J. V.
    MEDICAL PHYSICS, 2007, 34 (06) : 1944 - 1951
  • [4] Variability of patient positioning and prostate motion in 3D conformal radiotherapy of localized prostate cancer
    Rudat, V
    Schraube, P
    Flentje, M
    Oetzel, D
    Zierhut, D
    Wannenmacher, M
    EUROPEAN JOURNAL OF CANCER, 1995, 31A : 457 - 457
  • [5] Accuracy of an Automatic Patient-Positioning System Based on the Correlation of Two Edge Images in Radiotherapy
    Yoon, Myonggeun
    Cheong, Minho
    Kim, Jinsung
    Shin, Dong Ho
    Park, Sung Yong
    Lee, Se Byeong
    JOURNAL OF DIGITAL IMAGING, 2011, 24 (02) : 322 - 330
  • [6] Accuracy of an Automatic Patient-Positioning System Based on the Correlation of Two Edge Images in Radiotherapy
    Myonggeun Yoon
    Minho Cheong
    Jinsung Kim
    Dong Ho Shin
    Sung Yong Park
    Se Byeong Lee
    Journal of Digital Imaging, 2011, 24 : 322 - 330
  • [7] Adaptive Radiotherapy in prostate conformal dynamic treatment
    Garibaldi, C
    Cattani, F
    Castiglioni, S
    Tagaste, B
    Riboldi, M
    Cambria, R
    Fossati, P
    Tosi, G
    Orecchia, R
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S73 - S73
  • [8] Simulated Patient Positioning Errors during the Radiotherapy of the Prostate: A Plan Analysis of Different Radiation Techniques
    Schuessler, A.
    Waletzko, O.
    Loot, K.
    Wieting, M.
    Rohn, R.
    Block, A.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2018, 194 : S163 - S164
  • [9] Positioning errors and prostate motion during conformal prostate radiotherapy using on-line isocentre set-up verification and implanted prostate markers
    Wu, J
    Haycocks, T
    Alasti, H
    Ottewell, G
    Middlemiss, N
    Abdolell, M
    Warde, P
    Toi, A
    Catton, C
    RADIOTHERAPY AND ONCOLOGY, 2001, 61 (02) : 127 - 133
  • [10] Combined error of patient positioning variability and prostate motion uncertainty in 3D conformal radiotherapy of localized prostate cancer
    Rudat, V
    Schraube, P
    Oetzel, D
    Zierhut, D
    Flentje, M
    Wannenmacher, M
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (05): : 1027 - 1034