Effect of the collimator angle on dosimetric verification of volumetric modulated arc therapy

被引:0
|
作者
Yong Ho Kim
Ha Ryung Park
Won Taek Kim
Dong Won Kim
Yongkan Ki
Juhye Lee
Jinsuk Bae
Dahl Park
Hosang Jeon
Ji Ho Nam
机构
[1] Pusan National University Hospital,Department of Radiation Oncology, Pusan National University School of Medicine, Biomedical Research Institute
[2] Pusan National University Yangsan Hospital,Department of Radiation Oncology
来源
关键词
VMAT; Patient specific QA; Collimator angle;
D O I
暂无
中图分类号
学科分类号
摘要
The collimator is usually rotated when planning volumetric modulated arc therapy (VMAT) due to the leakage of radiation between the multi-leaf collimator (MLC) leaves. We studied the effect of the collimator angle on the results of dosimetric verification of VMAT plans for head and neck patients. We studied VMAT plans for 10 head and neck patients. We made two sets of VMAT plans for each patient. Each set was composed of 10 plans with collimator angles of 0, 5, 10, 15, 20, 25, 30, 35, 40, 45 degrees. Plans in the first set were optimized individually, and plans in the second set shared the 30-degree collimator-angle optimization. The two sets of plans were verified by using the 2-dimensional ion chamber array MatriXX (IBA Dosimetry, Germany). The comparisons between the calculation and the measurements were made by using a γ-index analysis. The γ-index (2%/2 mm) and (3%/3 mm) passing rates had negative correlations with the collimator angle. The maximum difference between γ-index (3%/3 mm) passing rates of different collimator angles for each patient ranged from 1.46% to 5.60% with an average of 3.67%. There were significant differences (maximum 5.6%) in the passing rates for different collimator angles. The results suggested that the accuracy of the delivered dose depended on the collimator angle. These findings are informative when choosing a collimator angle for VMAT plans.
引用
收藏
页码:243 / 247
页数:4
相关论文
共 50 条
  • [21] Dosimetric effect of multileaf collimator leaf width on volumetric modulated arc stereotactic radiotherapy for spine tumors
    Amoush, Ahmad
    Long, Huang
    Subedi, Laxmi
    Qi, Peng
    Djemil, Toufik
    Xia, Ping
    [J]. MEDICAL DOSIMETRY, 2017, 42 (02) : 111 - 115
  • [22] Effect of Collimator Angles on the Dosimetric Results of Volumetric Modulated Arc Therapy Planning for Patients with a Locally-Advanced Nasopharyngeal Carcinoma
    Kim, Yong Ho
    Park, Dahl
    Park, Ha Ryung
    Kim, Won Taek
    Kim, Dong Hyun
    Bae, Jin Suk
    Jeon, Gye Rok
    Ro, Jung Hoon
    Ki, Yongkan
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2017, 70 (05) : 539 - 544
  • [23] Verification of Mechanical and Dosimetric Accuracy for Head and Neck Volumetric Modulated Arc Therapy With Jaw Tracking
    Okumura, T.
    Nakashima, T.
    Aita, M.
    Ochi, Y.
    Kawahara, D.
    Masuda, H.
    Hioki, K.
    Ohno, Y.
    Saito, A.
    Nagata, Y.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E638 - E638
  • [24] DOSIMETRIC PERFORMANCE OF A 2D DIODE ARRAY FOR VERIFICATION OF VOLUMETRIC MODULATED ARC THERAPY
    Nakada, R.
    Tatsumi, D.
    Sakamoto, M.
    Inoue, M.
    Ichida, T.
    Ishii, K.
    Tsutsumi, S.
    Ogino, R.
    Hosono, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S212 - S212
  • [25] In Vivo Dosimetric Verification of Volumetric Modulated Arc Therapy for Prostate Cancer using a Rectal Balloon
    Fontenot, J. D.
    Price, M.
    King, M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S819 - S819
  • [26] 3D Dosimetric verification of volumetric-modulated arc therapy by portal dosimetry
    Mans, Anton
    Remeijer, Peter
    Olaciregui-Ruiz, Igor
    Wendling, Markus
    Sonke, Jan-Jakob
    Mijnheer, Ben
    van Herk, Marcel
    Stroom, Joep C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 94 (02) : 181 - 187
  • [27] Dosimetric Effect On Variation of Patient Size in Prostate Volumetric Modulated Arc Therapy
    Chow, J.
    Jiang, R.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3825 - 3825
  • [28] Dosimetric effects of sectional adjustments of collimator angles on volumetric modulated arc therapy for irregularly-shaped targets
    Ahn, Beom Seok
    Park, So-Yeon
    Park, Jong Min
    Choi, Chang Heon
    Chun, Minsoo
    Kim, Jung-in
    [J]. PLOS ONE, 2017, 12 (04):
  • [29] Collimator angle influence on dose distribution optimization for vertebral metastases using volumetric modulated arc therapy
    Mancosu, Pietro
    Cozzi, Luca
    Fogliata, Antonella
    Lattuada, Paola
    Reggiori, Giacomo
    Cantone, Marie Claire
    Navarria, Pierina
    Scorsetti, Marta
    [J]. MEDICAL PHYSICS, 2010, 37 (08) : 4133 - 4137
  • [30] Correction: Effect of Collimator Angles on the Dosimetric Results of Volumetric Modulated Arc Therapy Planning for Patients with a Locally-Advanced Nasopharyngeal Carcinoma
    Yong Ho Kim
    Dahl Park
    Ha Ryung Park
    Won Taek Kim
    Dong Hyun Kim
    Jin Suk Bae
    Gye Rok Jeon
    Jung Hoon Ro
    Yongkan Ki
    [J]. Journal of the Korean Physical Society, 2019, 75 : 748 - 748