Evaluation of surface dose and image quality using the half-scan mode in chest computed tomography-guided interventional radiology: a phantom study

被引:1
|
作者
Hasegawa H. [1 ]
Sato J. [1 ]
Kobayashi I. [2 ]
机构
[1] Department of Radiology, The University of Tokyo Hospital, 7-3-1, Hongo, Bunkyo-ku, Tokyo
[2] Nagase-Landauer, Ltd., Block C22-1, Suwa, Tsukuba, 300-2686, Ibaraki
关键词
Computed tomography; Half-scan; Interventional radiology; Optically stimulated luminescent dosimeter; Physicians’ radiation exposure; Radiation protection;
D O I
10.1007/s12194-018-0445-6
中图分类号
学科分类号
摘要
The authors aimed to evaluate the effects of the half-scan mode on image quality and physician exposure to radiation in computed tomography (CT)-guided interventional radiology (IVR) to the right lung using an intermittent CT fluoroscopy technique for measuring phantom surface dose distribution and image noise. For the half-scan mode, settings at 0°, 90°, 180°, and 270° were used as the central axis of the X-ray exposure range on the chest phantom. With the center of the ventral side in the chest phantom defined as 0°, optically stimulated luminescent dosimeters were attached at five positions at 30° intervals on the right side of the phantom surface. Securing a space for device operation during the procedure is necessary. The couch was shifted downward by 50 mm to reproduce the conditions used for measurement in clinical settings. Image noise and contrast-to-noise ratio were measured to assess image quality; subjective evaluation was performed using simulated lung nodules placed in the phantom. The phantom surface dose distribution in the measured half-scan mode depended on the angle setting. Additionally, the phantom surface dose in the half-scan mode at the 90° setting was reduced by approximately 50%; however, image quality was clearly decreased. In CT-guided IVR to the right lung, using a lead drape and half-scan mode according to the procedural situation is important. © 2018, Japanese Society of Radiological Technology and Japan Society of Medical Physics.
引用
收藏
页码:138 / 148
页数:10
相关论文
共 50 条
  • [1] Phantom study for comparison between computed tomography- and C-Arm computed tomography-guided puncture applied by residents in radiology
    Meine, Timo C.
    Hinrichs, Jan B.
    Werncke, Thomas
    Afat, Saif
    Biggemann, Lorenz
    Bucher, Andreas
    Buettner, Martina
    Christner, Sara
    Dethlefsen, Ebba
    Engel, Hannes
    Gerwing, Mirjam
    Getzin, Tobias
    Graeger, Stephanie
    Gresser, Eva
    Grunz, Jan-Peter
    Harder, Felix
    Heidenreich, Julius
    Hitpass, Lea
    Jakobi, Kristina
    Janisch, Michael
    Kocher, Nadja
    Kopp, Markus
    Lennartz, Simon
    Martin, Ole
    Alsady, Tawfik Moher
    Pamminger, Matthias
    Pedersoli, Frederico
    Piechotta, Paula Louise
    da Silva, Natascha Platz Batista
    Raudner, Marcus
    Roehrich, Sebastian
    Schindler, Philipp
    Schwarze, Vincent
    Seppelt, Danilo
    Sieren, Malte M.
    Spurny, Manuela
    Starekova, Jitka
    Storz, Corinna
    Wiesmueller, Marco
    Zopfs, David
    Ringe, Kristina Imeen
    Meyer, Bernhard C.
    Wacker, Frank K.
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2022, 194 (03): : 272 - 280
  • [2] Evaluation of Image Quality for 7 Iterative Reconstruction Algorithms in Chest Computed Tomography Imaging: A Phantom Study
    Jensen, Kristin
    Hagemo, Guro
    Tingberg, Anders
    Steinfeldt-Reisse, Claudius
    Mynarek, Georg Karl
    Rivero, Rodriguez Jezabel
    Fosse, Erik
    Martinsen, Anne Catrine
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2020, 44 (05) : 673 - 680
  • [3] Evaluation of Computed Tomography Scan Ability in Detecting Chest Nodules Using Tissue Equivalent Phantom
    Changizi, Vahid
    [J]. Current Medical Imaging Reviews, 2015, 11 (01) : 56 - 62
  • [4] The Dose Optimization and Evaluation of Image Quality in the Adult Brain Protocols of Multi-Slice Computed Tomography: A Phantom Study
    Prabsattroo, Thawatchai
    Wachirasirikul, Kanokpat
    Tansangworn, Prasit
    Punikhom, Puengjai
    Sudchai, Waraporn
    [J]. JOURNAL OF IMAGING, 2023, 9 (12)
  • [5] How Localizer Orders Impact Image Quality and Radiation Dose in Computed Tomography - A Phantom Study
    Jimenez, J.
    Rong, J.
    Jensen, C.
    Jones, A.
    Liu, X.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E538 - E538
  • [6] Evaluation of a Robotic Assistance-System For Percutaneous Computed Tomography-Guided (CT-Guided) Facet Joint Injection: A Phantom Study
    Beyer, Lukas Philipp
    Michalik, Katharina
    Niessen, Christoph
    da Silva, Natascha Platz Batista
    Wiesinger, Isabell
    Stroszczynski, Christian
    Wiggermann, Philipp
    [J]. MEDICAL SCIENCE MONITOR, 2016, 22 : 3334 - 3339
  • [7] Absorbed dose and image quality according to the scan mode and shield position in pediatric brain computed tomography scans
    Bae, Eunmi
    Cho, Youngkwon
    Kim, Sungchul
    [J]. RADIATION PROTECTION DOSIMETRY, 2023, 199 (05) : 385 - 390
  • [8] Radiation dose reduction using deep learning-based image reconstruction for a low-dose chest computed tomography protocol: a phantom study
    Jung, Yunsub
    Hur, Jin
    Han, Kyunghwa
    Imai, Yasuhiro
    Hong, Yoo Jin
    Im, Dong Jin
    Lee, Kye Ho
    Desnoyers, Melissa
    Thomsen, Brian
    Shigemasa, Risa
    Um, Kyounga
    Jang, Kyungeun
    [J]. QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (03) : 1937 - +
  • [9] Evaluation of the impact of organ-specific dose reduction on image quality in pediatric chest computed tomography
    Boos, Johannes
    Kroepil, Patric
    Klee, Dirk
    Heusch, Philipp
    Schimmoeller, Lars
    Schaper, Joerg
    Antoch, Gerald
    Lanzman, Rotem S.
    [J]. PEDIATRIC RADIOLOGY, 2014, 44 (09) : 1065 - 1069
  • [10] Evaluation of the impact of organ-specific dose reduction on image quality in pediatric chest computed tomography
    Johannes Boos
    Patric Kröpil
    Dirk Klee
    Philipp Heusch
    Lars Schimmöller
    Jörg Schaper
    Gerald Antoch
    Rotem S. Lanzman
    [J]. Pediatric Radiology, 2014, 44 : 1065 - 1069