Absorbed dose and image quality according to the scan mode and shield position in pediatric brain computed tomography scans

被引:0
|
作者
Bae, Eunmi [1 ]
Cho, Youngkwon [2 ]
Kim, Sungchul [3 ]
机构
[1] Korea Med Inst Suwon Ctr, Dept Diagnost Radiol, Suwon, Gyeonggi Do, South Korea
[2] Cheongju Univ, Coll Hlth Sci, Dept Radiol Sci, 298 Cheongwon Gu, Cheongju, Chungcheongbug, South Korea
[3] Gachon Univ Med Campus, Dept Radiol Sci, Hambakmoe Ro, Incheon, South Korea
关键词
CHILDREN; CHEST;
D O I
10.1093/rpd/ncad001
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study, computed tomography dose index (CTDIvol), dose-length product (DLP), organ dose and signal-to-noise ratio (SNR) were measured in pediatric brain helical and volumetric CT scans using a pediatric phantom (equivalent to a 10-year-old) and optically stimulated luminescence dosemeters (OSLD) as the scan protocol used in Hospital A. Volumetric scans showed lower CTDIvol, DLP and organ dose than helical scans, and the SNR showed similar results. The organ doses were lower in the phantoms protected with front, rear or front and rear shielding than in those without shielding. However, no statistically significant differences were found among the different shield locations. In pediatric brain CT scans, to reduce exposure dose and patient discomfort while maintaining image quality, a volumetric scan rather than a helical scan was preferred, and a good shielding effect was observed with front or rear shielding.
引用
收藏
页码:385 / 390
页数:6
相关论文
共 50 条
  • [1] Optimization of dose and image quality in adult and pediatric computed tomography scans
    Chang, Kwo-Ping
    Hsu, Tzu-Kun
    Lin, Wei-Ting
    Hsu, Wen-Lin
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2017, 140 : 260 - 265
  • [2] Radiation Dose and Image Quality in Adult Computed Tomography Scans
    Al Ewaidat, Haytham
    Zheng, Xiaoming
    Khader, Yousef
    Theeb, Mostafa Abdelrahman
    Alhasan, Mostafa Khaled Mustafa
    Rawashdeh, Mohammad Ahmmad
    Al Mousa, Dana Samir
    Alawneh, Khaled Zayed Ali
    [J]. JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2018, 8 (02) : 223 - 231
  • [3] Optimizing dose and image quality in pediatric computed tomography
    Jones, A.
    Huston, A.
    Falkenstien, P.
    Williams, J.
    Staton, R.
    Hintenlang, D.
    Arreola, M.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2002 - 2002
  • [4] Effect of arm position on image quality and radiation dose during thorax and abdomen computed tomography scans
    Buchhave, E. O.
    Rasmussen, C. D.
    Lentz, R.
    Frederiksen, E. H.
    Kipp, J. O.
    Leftes, M. O.
    [J]. RADIOGRAPHY, 2024, 30 (04) : 1035 - 1040
  • [5] Image quality and dose in computed tomography
    Jurik, AG
    Jessen, KA
    Hansen, J
    [J]. EUROPEAN RADIOLOGY, 1997, 7 (01) : 77 - 81
  • [6] Image quality and dose in computed tomography
    A. G. Jurik
    K. A. Jessen
    J. Hansen
    [J]. European Radiology, 1997, 7 : 77 - 81
  • [7] Evaluation of Computed Tomography Scan of Brain in Pediatric Patients
    Mansoor, Mahwash
    Bazai, Rizwana Rahman
    [J]. PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2021, 15 (12): : 3433 - 3434
  • [8] Optimization of the pediatric head computed tomography scan image quality: Reducing dose with an automatic tube potential selection in infants
    Morel, Baptiste
    Bouette, Aurelien
    Levy, Pierre
    Antoni, Guillemette
    Chalard, Francois
    Blondiaux, Eleonore
    Le Pointe, Hubert Ducou
    [J]. JOURNAL OF NEURORADIOLOGY, 2016, 43 (06) : 398 - 403
  • [9] Effect of Arm Position on Image Quality and Radiation Dose in Multidetector Computed Tomography
    Kweon, Dae Cheol
    Choi, Jiwon
    [J]. IRANIAN JOURNAL OF RADIOLOGY, 2019, 16 (04)
  • [10] Absorbed dose model to scan parameters in dental cone beam computed tomography
    Jia, Shumei
    Guo, Xiaoyue
    Xing, Yuxiang
    Zhang, Li
    [J]. 2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,