Absorbed dose model to scan parameters in dental cone beam computed tomography

被引:0
|
作者
Jia, Shumei [1 ]
Guo, Xiaoyue [1 ]
Xing, Yuxiang [1 ]
Zhang, Li [1 ]
机构
[1] Tsinghua Univ, Dept Engn Phys, Minist Educ, Key Lab Particle & Radiat Imaging, Beijing 100084, Peoples R China
关键词
CT;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Cone beam computed tomography (CBCT) is widely applied in dental and maxillofacial diagnostic imaging, which raises great concerns to radiological dose caused by this device. This work measures the absorbed dose inside an uniform cylindrical phantom when it is scanned by dental CBCT at different scan parameters of mAs and kV; meanwhile, studies the relationship of absorbed dose to scan parameters. The result indicates that absorbed dose is correlated to scan parameters in an empirical model form of D = (a center dot HVL2 + b) center dot mAs with coefficient of determination above 0.99. This empirical model can be applied to other type dental CBCT devices to provide as an estimation method of radiology dose at different scan parameter settings. Moreover, absorbed dose is proportional to field of view size and inversely proportional to phantom size.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Dental and Maxillofacial Cone Beam Computed Tomography Absorbed Dose Distribution Calculation by GEANT4
    Jia, Shumei
    Gao, Hewei
    Zhang, Li
    Xing, Yuxiang
    Zheng, Junzheng
    MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [2] Superimposition of a cone beam computed tomography (CBCT) scan and a photograph: A dental technique
    Lee, Soo Young
    Kim, Heechul
    Lee, Doyun
    Park, Chan
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (02): : 212 - 215
  • [3] Effective dose range for dental cone beam computed tomography scanners
    Pauwels, Ruben
    Beinsberger, Jilke
    Collaert, Bruno
    Theodorakou, Chrysoula
    Rogers, Jessica
    Walker, Anne
    Cockmartin, Lesley
    Bosmans, Hilde
    Jacobs, Reinhilde
    Bogaerts, Ria
    Horner, Keith
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (02) : 267 - 271
  • [4] Dental and Maxillofacial Cone Beam Computed Tomography Dose Index in Full-Fan and Full-Scan Mode
    Jia, S.
    Zhang, L.
    Xing, Y.
    Gao, H.
    MEDICAL PHYSICS, 2020, 47 (06) : E524 - E525
  • [5] Comment on "Effective dose range for dental cone beam computed tomography scanners"
    Ludlow, John B.
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (12) : 4219 - 4220
  • [6] MONTE CARLO DOSE ASSESSMENT IN DENTAL CONE-BEAM COMPUTED TOMOGRAPHY
    Kim, Jinwoo
    Jeon, Hosang
    Kim, Ho Kyung
    RADIATION PROTECTION DOSIMETRY, 2021, 193 (3-4) : 190 - 199
  • [7] Create virtual dentoskeletal model by superimposing digital dental cast into cone-beam computed tomography scan
    Mahmood, Reem Shakir
    Hamandi, Sadiq Jafer Abbas
    Al-Mahdi, Akmam Hamdy
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2024, 19 (09) : 1855 - 1864
  • [8] Organ dose and radiogenic risk in dental cone-beam computed tomography examinations
    Almuqrin, Aljawhara H.
    Tamam, Nissren
    Abdelrazig, A.
    Elnour, A.
    Sulieman, Abdelmoneim
    RADIATION PHYSICS AND CHEMISTRY, 2020, 176
  • [9] Distribution of Absorbed Dose in Cone-Beam Breast Computed Tomography: a Phantom Study with Radiochromic Films
    Russo, Paolo
    Coppola, Teresa
    Mettivier, Giovanni
    Montesi, Maria Cristina
    Lauria, Adele
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3463 - 3470
  • [10] Distribution of Absorbed Dose in Cone-Beam Breast Computed Tomography: A Phantom Study With Radiochromic Films
    Russo, Paolo
    Coppola, Teresa
    Mettivier, Giovanni
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (04) : 2220 - 2229