Enzyme mass-transfer coefficient in aqueous two-phase systems using static mixer extraction column

被引:0
|
作者
K. Rostami
M. Alamshahi
机构
[1] No. 71 Forsat Street,
[2] Biotechnology Center,undefined
[3] Iranian Research Organization for Science and Technology,undefined
[4] Tehran-15819,undefined
[5] Iran,undefined
来源
关键词
Enzyme mass transfer Static mixer Aqueous two-phase system;
D O I
暂无
中图分类号
学科分类号
摘要
Recent technical advances in aqueous two-phase systems (ATPS) have made this a sound technique for the extraction of biomacromolecules. The extraction of α-amylase was investigated using aqueous two-phase systems formed by sodium sulphate–polyethylene glycol (PEG) in water in a 47-mm inner diameter spray column packed with three types of static mixers. The effects of dispersed-phase flow rate, phase composition, column height and diameter were studied. The extraction column was operated in a semi-batch manner. It was found that the hold-up and volumetric mass transfer coefficients increased with an increase in dispersed (PEG-rich) phase velocity and decreased with increasing phase composition. Empirical correlations were developed for fractional dispersed-phase hold-up and volumetric mass transfer coefficients.
引用
收藏
页码:169 / 178
页数:9
相关论文
共 50 条
  • [1] Enzyme mass-transfer coefficient in aqueous two-phase systems using static mixer extraction column
    Rostami, K
    Alamshahi, M
    BIOPROCESS AND BIOSYSTEMS ENGINEERING, 2002, 25 (03) : 169 - 178
  • [2] ENZYME MASS-TRANSFER COEFFICIENT IN AQUEOUS 2 PHASE SYSTEM USING A PACKED EXTRACTION COLUMN
    PATIL, TA
    JAFARABAD, KR
    SAWANT, SB
    JOSHI, JB
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1991, 69 (02): : 548 - 556
  • [3] Lipoxygenase-1 mass-transfer coefficient in aqueous two-phase system using spray extraction column
    Arsalani, V
    Rostami, K
    Kheirolomoom, A
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2005, 44 (19) : 7469 - 7473
  • [4] Enzyme mass transfer coefficient in aqueous two-phase systems: Modified spray extraction columns
    Pawar, PA
    Veera, UP
    Sawant, SB
    Joshi, JB
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1997, 75 (04): : 751 - 758
  • [5] ENZYME MASS-TRANSFER COEFFICIENT IN AQUEOUS 2-PHASE SYSTEMS - SPRAY EXTRACTION COLUMNS
    PAWAR, PA
    JAFARABAD, KR
    SAWANT, SB
    JOSHI, JB
    CHEMICAL ENGINEERING COMMUNICATIONS, 1993, 122 : 151 - 169
  • [6] ENZYME AND PROTEIN MASS-TRANSFER COEFFICIENT IN AQUEOUS 2-PHASE SYSTEMS .2. YORK-SCHEIBEL EXTRACTION COLUMN
    JAFARABAD, KR
    PATIL, TA
    SAWANT, SB
    JOSHI, JB
    CHEMICAL ENGINEERING SCIENCE, 1992, 47 (01) : 69 - 73
  • [7] ENZYME MASS-TRANSFER COEFFICIENT IN A SIEVE-PLATE EXTRACTION COLUMN
    BHAWSAR, PCM
    PANDIT, AB
    SAWANT, SB
    JOSHI, JB
    CHEMICAL ENGINEERING JOURNAL AND THE BIOCHEMICAL ENGINEERING JOURNAL, 1994, 55 (1-2): : B1 - B17
  • [8] ENZYME AND PROTEIN MASS-TRANSFER COEFFICIENT IN AQUEOUS 2-PHASE SYSTEMS .1. SPRAY EXTRACTION COLUMNS
    JAFARABAD, KR
    SAWANT, SB
    JOSHI, JB
    SIKDAR, SK
    CHEMICAL ENGINEERING SCIENCE, 1992, 47 (01) : 57 - 68
  • [9] MIXER SETTLER EXTRACTION COLUMN - MASS-TRANSFER EFFICIENCY AND ENTRAINMENT
    HORVATH, M
    HARTLAND, S
    INDUSTRIAL & ENGINEERING CHEMISTRY PROCESS DESIGN AND DEVELOPMENT, 1985, 24 (04): : 1220 - 1225
  • [10] MASS-TRANSFER IN BUBBLE SLURRY COLUMN WITH STATIC MIXER IN DRAFT TUBE
    GASPILLO, PAD
    GOTO, S
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1991, 24 (05) : 680 - 682