摘要
Fractional dispersed phase hold-up and dispersed side mass transfer coefficients for bovine serum albumin (BSA) and amyloglucosidase (AMG) were measured in 50 mm i.d. York-Scheibel columns using salt-polyethylene glycol (4000), potassium phosphate-PEG and sodium sulphate-PEG, systems. The effect of column height and the effect of phase compositions of the aqueous phase system were studied. The critical impeller speed for flooding and the critical superficial dispersed phase velocity for flooding were measured. Empirical correlations have been developed for fractional dispersed phase hold-up and dispersed side mass transfer coefficients. The performance of the York-Scheibel column has been compared with that of the spray column.
引用
收藏
页码:69 / 73
页数:5
相关论文
共 50 条
  • [1] ENZYME MASS-TRANSFER COEFFICIENT IN AQUEOUS 2-PHASE SYSTEMS - SPRAY EXTRACTION COLUMNS
    PAWAR, PA
    JAFARABAD, KR
    SAWANT, SB
    JOSHI, JB
    CHEMICAL ENGINEERING COMMUNICATIONS, 1993, 122 : 151 - 169
  • [2] ENZYME AND PROTEIN MASS-TRANSFER COEFFICIENT IN AQUEOUS 2-PHASE SYSTEMS .1. SPRAY EXTRACTION COLUMNS
    JAFARABAD, KR
    SAWANT, SB
    JOSHI, JB
    SIKDAR, SK
    CHEMICAL ENGINEERING SCIENCE, 1992, 47 (01) : 57 - 68
  • [3] ENZYME MASS-TRANSFER COEFFICIENT IN AQUEOUS 2 PHASE SYSTEM USING A PACKED EXTRACTION COLUMN
    PATIL, TA
    JAFARABAD, KR
    SAWANT, SB
    JOSHI, JB
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1991, 69 (02): : 548 - 556
  • [4] MASS-TRANSFER COEFFICIENTS IN 2-PHASE AQUEOUS EXTRACTION
    PATIL, TA
    SAWANT, SB
    JOSHI, JB
    SIKDAR, SK
    CHEMICAL ENGINEERING JOURNAL AND THE BIOCHEMICAL ENGINEERING JOURNAL, 1988, 39 (01): : B1 - B6
  • [5] INTENSIFICATION OF MASS-TRANSFER IN AQUEOUS 2-PHASE SYSTEMS
    SAVE, SV
    PANGARKAR, VG
    KUMAR, SV
    BIOTECHNOLOGY AND BIOENGINEERING, 1993, 41 (01) : 72 - 78
  • [6] Enzyme mass-transfer coefficient in aqueous two-phase systems using static mixer extraction column
    Rostami, K
    Alamshahi, M
    BIOPROCESS AND BIOSYSTEMS ENGINEERING, 2002, 25 (03) : 169 - 178
  • [7] Enzyme mass-transfer coefficient in aqueous two-phase systems using static mixer extraction column
    K. Rostami
    M. Alamshahi
    Bioprocess and Biosystems Engineering, 2002, 25 : 169 - 178
  • [8] MEASUREMENT OF PROTEIN INTERFACIAL MASS-TRANSFER COEFFICIENTS IN AQUEOUS 2-PHASE SYSTEMS
    SLAFF, GF
    JOURNAL OF CELLULAR BIOCHEMISTRY, 1987, : 184 - 184
  • [9] HYDRODYNAMICS AND MASS-TRANSFER IN 2-PHASE AQUEOUS EXTRACTION USING SPRAY COLUMNS
    SAWANT, SB
    SIKDAR, SK
    JOSHI, JB
    BIOTECHNOLOGY AND BIOENGINEERING, 1990, 36 (02) : 109 - 115
  • [10] ENZYME MASS-TRANSFER COEFFICIENT IN A SIEVE-PLATE EXTRACTION COLUMN
    BHAWSAR, PCM
    PANDIT, AB
    SAWANT, SB
    JOSHI, JB
    CHEMICAL ENGINEERING JOURNAL AND THE BIOCHEMICAL ENGINEERING JOURNAL, 1994, 55 (1-2): : B1 - B17