Enzyme mass-transfer coefficient in aqueous two-phase systems using static mixer extraction column

被引:0
|
作者
K. Rostami
M. Alamshahi
机构
[1] No. 71 Forsat Street,
[2] Biotechnology Center,undefined
[3] Iranian Research Organization for Science and Technology,undefined
[4] Tehran-15819,undefined
[5] Iran,undefined
来源
关键词
Enzyme mass transfer Static mixer Aqueous two-phase system;
D O I
暂无
中图分类号
学科分类号
摘要
Recent technical advances in aqueous two-phase systems (ATPS) have made this a sound technique for the extraction of biomacromolecules. The extraction of α-amylase was investigated using aqueous two-phase systems formed by sodium sulphate–polyethylene glycol (PEG) in water in a 47-mm inner diameter spray column packed with three types of static mixers. The effects of dispersed-phase flow rate, phase composition, column height and diameter were studied. The extraction column was operated in a semi-batch manner. It was found that the hold-up and volumetric mass transfer coefficients increased with an increase in dispersed (PEG-rich) phase velocity and decreased with increasing phase composition. Empirical correlations were developed for fractional dispersed-phase hold-up and volumetric mass transfer coefficients.
引用
收藏
页码:169 / 178
页数:9
相关论文
共 50 条
  • [21] Protein extraction using aqueous two-phase systems.
    Kula, MRA
    Selber, K
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2001, 221 : U130 - U130
  • [22] Continuous aqueous two-phase extraction of human antibodies using a packed column
    Rosa, P. A. J.
    Azevedo, A. M.
    Sommerfeld, S.
    Baecker, W.
    Aires-Barros, M. R.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 880 : 148 - 156
  • [23] MASS-TRANSFER COEFFICIENTS IN 2-PHASE AQUEOUS EXTRACTION
    PATIL, TA
    SAWANT, SB
    JOSHI, JB
    SIKDAR, SK
    CHEMICAL ENGINEERING JOURNAL AND THE BIOCHEMICAL ENGINEERING JOURNAL, 1988, 39 (01): : B1 - B6
  • [24] Plant Extraction with Aqueous Two-Phase Systems
    Schneider, Peter
    Bischoff, Friedrich
    Mueller, Ulrich
    Bart, Hans-Joerg
    Schlitter, Klaus
    Jordan, Volkmar
    CHEMICAL ENGINEERING & TECHNOLOGY, 2011, 34 (03) : 452 - 458
  • [25] HYDRODYNAMICS AND MASS-TRANSFER IN 2-PHASE AQUEOUS EXTRACTION USING SPRAY COLUMNS
    SAWANT, SB
    SIKDAR, SK
    JOSHI, JB
    BIOTECHNOLOGY AND BIOENGINEERING, 1990, 36 (02) : 109 - 115
  • [26] EXTRACTION AND PURIFICATION OF ENZYMES USING AQUEOUS TWO-PHASE SYSTEMS.
    Kula, Maria Regina
    Applied Biochemistry and Bioengineering, 1979, 2 : 71 - 95
  • [27] Measurement of mass transfer coefficients and their modelling of continuous counter-current aqueous two-phase system in a packed extraction column
    Yan, GX
    Zhu, ZQ
    Guan, YX
    Han, ZX
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 1999, 7 (03) : 196 - 204
  • [28] Measurement of Mass Transfer Coefficients and Their Modelling of Continuous Counter-Current Aqueous Two-Phase System in a Packed Extraction Column
    阎恭喜
    朱自强
    关怡新
    韩兆熊
    Chinese Journal of Chemical Engineering, 1999, (03) : 12 - 20
  • [29] MASS-TRANSFER COEFFICIENT BETWEEN THE STATIC AND DYNAMIC HOLD-UPS IN A PACKED-COLUMN
    PATWARDHAN, VS
    SHROTRI, VR
    CHEMICAL ENGINEERING COMMUNICATIONS, 1981, 10 (06) : 349 - 356
  • [30] HYDRODYNAMICS AND MASS-TRANSFER CHARACTERISTICS OF 2 PHASE AQUEOUS EXTRACTION SYSTEM
    RAO, KSMSR
    KHOSRO, R
    SAWANT, SB
    JOSHI, JB
    SIKDAR, SK
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1988, 195 : 161 - IEC