Assessment of coronary artery stent patency by electron-beam CT

被引:0
|
作者
Friedrich D. Knollmann
Jörg Möller
Axel Gebert
Christian Bethge
Roland Felix
机构
[1] Humboldt-University,Department of Radiology, Charité, Campus Virchow
[2] Jüdisches Krankenhaus,Klinikum
来源
European Radiology | 2004年 / 14卷
关键词
Electron-beam computed tomography; Cardiac imaging; Coronary vessels; Stents;
D O I
暂无
中图分类号
学科分类号
摘要
Following coronary angioplasty and stent implantation, restenosis remains common and its outcome difficult to predict. We set out to determine the diagnostic accuracy of electron-beam computed tomography (EBCT) for the non-invasive detection of stent obstruction. In a prospective, blinded investigation, we included 152 coronary artery segments in 117 patients treated with a stent implant. All segments were evaluated by a dynamic EBCT study that depicted contrast bolus passage distal to the stent and a CT angiographic study of the entire coronary arteries. It was found that delayed contrast enhancement in the distal segment correlated with angiographic stent obstruction (Spearman’s rank correlation, P=0.008), while all other indicators of stent occlusion did not correlate with angiographic diagnosis. However, direct comparison of patients with obstruction of less vs. more than 75% of luminal diameter did not yield any statistically significant differences of distal enhancement delay, and for the detection of >90% occlusion, the sensitivity was 72% at a specificity of 60%. Although delayed contrast enhancement distal to the stent upon EBCT did correlate with angiographical obstruction, the correlation did not suffice to appear clinically satisfactory.
引用
收藏
页码:1341 / 1347
页数:6
相关论文
共 50 条
  • [31] Coronary artery disease: Improved reproducibility of calcium scoring with an electron-beam CT volumetric method
    Callister, TQ
    Cooil, B
    Raya, SP
    Lippolis, NJ
    Russo, DJ
    Raggi, P
    [J]. RADIOLOGY, 1998, 208 (03) : 807 - 814
  • [32] Optimal electrocardiographically triggered phase for reducing motion artifact at electron-beam CT in the coronary artery
    He, S
    Dai, RP
    Chen, Y
    Bai, H
    [J]. ACADEMIC RADIOLOGY, 2001, 8 (01) : 48 - 56
  • [33] Coronary artery calcium quantification at multi-detector row helical CT versus electron-beam CT
    Stanford, W
    Thompson, BH
    Burns, TL
    Heery, SD
    Burr, MC
    [J]. RADIOLOGY, 2004, 230 (02) : 397 - 402
  • [34] Preview method for electron-beam CT scanning of the coronary arteries
    Bakhsheshi, H
    Mao, SS
    Budoff, MJ
    Bin, L
    Brundage, BH
    [J]. ACADEMIC RADIOLOGY, 2000, 7 (08) : 620 - 626
  • [35] RELIABILITY OF CORONARY CALCIUM QUANTIFICATION WITH ELECTRON-BEAM CT - REPLY
    KAUFMANN, RB
    BIELAK, LF
    MOLL, PP
    SHEEDY, PF
    BREEN, JF
    KELZENBERG, JR
    KRUGER, BL
    SCHWARTZ, RS
    [J]. RADIOLOGY, 1994, 193 (01) : 282 - 283
  • [36] Coronary calcification, detected by electron-beam CT, and cardiovascular disease
    Vliegenthart, R
    De Groot, JC
    Witteman, J
    Breteler, MM
    Hofman, A
    Oudkerk, M
    [J]. RADIOLOGY, 2001, 221 : 502 - 502
  • [37] COMPARISON OF ELECTRON-BEAM AND HELICAL COMPUTED-TOMOGRAPHY IN ASSESSMENT OF CORONARY-ARTERY CALCIFICATION
    BASKIN, KM
    STANFORD, W
    THOMPSON, BH
    HOFFMAN, E
    TAJIK, J
    HEERY, SD
    [J]. CIRCULATION, 1995, 92 (08) : 3124 - 3124
  • [38] Electron-beam computed tomography, coronary artery calcium, and evaluation of patients with coronary artery disease
    Fiorino, AS
    [J]. ANNALS OF INTERNAL MEDICINE, 1998, 128 (10) : 839 - 847
  • [39] CORONARY CALCIUM VOLUME BY ELECTRON-BEAM CT QUANTIFIES CORONARY PLAQUE VOLUME
    RUMBERGER, JA
    SIMONS, DB
    EDWARDS, WD
    FITZPATRICK, LA
    SHEEDY, PF
    SCHWARTZ, RS
    [J]. CIRCULATION, 1994, 90 (04) : 300 - 300
  • [40] Electron-beam CT coronary angiography: Imaging characteristics in normal coronary arteries
    Chernoff, DM
    Ritchie, CJ
    Higgins, CB
    [J]. RADIOLOGY, 1996, 201 : 789 - 789