Dependence of the beam current measurement on the operation parameters of the microwave ion source

被引:0
|
作者
Dae-il Kim
Hyeok-Jung Kwon
Han-Sung Kim
Kyung-Tae Seol
Yong-Sub Cho
机构
[1] Korea Atomic Energy Research Institute,Proton Engineering Frontier Project
来源
关键词
Microwave ion source; Beam extraction; Beam current;
D O I
暂无
中图分类号
学科分类号
摘要
The microwave ion source has been operated as a proton injector for the 20-MeV proton linac. The microwave ion source consists of the 2.45-GHz microwave components, a solenoid magnet, a vacuum system, power supplies for beam extraction and bias electrodes, and a cooling system. The beam current was measured under various operating conditions by changing the gas flow rate, solenoid magnet current and microwave power in order to find optimum operating conditions. In this paper, the measurement results are presented, and the optimum conditions are discussed.
引用
收藏
页码:1591 / 1594
页数:3
相关论文
共 50 条
  • [31] Beam characterization measurement of a duoplasmatron ion source for the Nanjing Proton Source
    Zhang, Hong
    Zhang, Pengjiao
    Song, Jie
    An, Sun
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1027
  • [32] BEAM EMITTANCE MEASUREMENT OF A POLARIZED ION-SOURCE
    NAQVI, AA
    HUTTEL, E
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 1995, 20 (03): : 561 - 569
  • [33] A BROAD BEAM MICROWAVE O+ ION-SOURCE
    FARCHI, A
    AUBERT, J
    WARTSKI, L
    COSTE, P
    MARDIROSSIAN, C
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1992, 25 (07) : 1149 - 1151
  • [34] A BROAD BEAM MICROWAVE N+ ION-SOURCE
    FARCHI, A
    AUBERT, J
    WARTSKI, L
    COSTE, P
    MARDIROSSIAN, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1993, 74 (03): : 457 - 459
  • [35] THE EXPERIMENTAL TEST OF A MICROWAVE ION-BEAM SOURCE IN OXYGEN
    ASMUSSEN, J
    DAHIMENE, M
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1987, 5 (01): : 328 - 331
  • [36] MEASUREMENT OF INSTABILITIES AND ION HEATING IN AN ELECTRON BEAM ION SOURCE.
    Levine, Morton A.
    Marrs, R.E.
    Schmieder, Robert W.
    Nuclear instruments and methods in physics research, 1985, A237 (03): : 429 - 440
  • [37] The influence of magnetic field on the ion beam current of Calutron ion source
    Cao, Jinwen
    Ren, Xiuyan
    Zeng, Ziqiang
    Wang, Guobao
    PROCEEDINGS OF THE 17TH INTERNATIONAL CONFERENCE ON ION SOURCES, 2018, 2011
  • [38] Dependence of proton beam polarization on ion source transition configurations
    Allgower, C.E.
    Arvieux, J.
    Ausset, P.
    Ball, J.
    Beauvais, P.-Y.
    Bedfer, Y.
    Bystricky, J.
    Chamouard, P.-A.
    Demierre, P.
    Fontaine, J.-M.
    Janout, Z.
    Kalinnikov, V.A.
    Kasprzyk, T.E.
    Khachaturov, B.A.
    Kunne, R.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1997, 399 (2-3): : 171 - 179
  • [39] Dependence of proton beam polarization on ion source transition configurations
    Allgower, CE
    Arvieux, J
    Ausset, P
    Ball, J
    Beauvais, PY
    Bedfer, Y
    Bystricky, J
    Chamouard, PA
    Demierre, P
    Fontaine, JM
    Janout, Z
    Kalinnikov, VA
    Kasprzyk, TE
    Khachaturov, BA
    Kunne, R
    Lagniel, JM
    Lehar, F
    deLesquen, A
    Popov, AA
    Prokofiev, AN
    Rapin, D
    Sans, JL
    Spinka, HM
    Teglia, A
    Vikhrov, VV
    Vuaridel, B
    Zhdanov, AA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 399 (2-3): : 171 - 179
  • [40] Ion beam measurement with a HTS squid current comparator
    Hao, L
    Macfarlane, JC
    Gallop, JC
    2000 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2000, : 480 - 481