Beam characterization measurement of a duoplasmatron ion source for the Nanjing Proton Source

被引:0
|
作者
Zhang, Hong [1 ]
Zhang, Pengjiao
Song, Jie
An, Sun
机构
[1] Nanjing Univ, Coll Engn & Appl Sci, Nanjing 210093, Peoples R China
关键词
Beam current measurement; Beam profile measurement; Beam emittance measurement; Duoplasmatron ion source; FARADAY CUP; LOW-ENERGY; EMITTANCE; DESIGN;
D O I
10.1016/j.nima.2021.166296
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The beam characterization studies in terms of beam current, beam profile and RMS normalized emittance have been carried out in a duoplasmatron ion source developed for the Nanjing Proton Source (NPS). A test chamber installed a Faraday cup, a beam profile monitor and an Allision type scanner have been developed to perform the beam current, beam profile and beam emittance measurement, respectively. To solve the sparking problem of the ion source, we have used physical vapor deposition (PVD) to coat a zirconia film with a thickness of 3 mu m on the full surface of the extraction electrodes. The beam parameters have been measured at two locations (1) after beam extraction at the ion source end, (2) after focusing the beam using two solenoid magnets of low energy beam transport (LEBT). The relationship between arc current and gas pressure has been studied and the optimal operating point of gas pressure is found to be 1.0 x 10(-3) Pa with corresponding hydrogen flow rate is 0.5 SCCM. At the ion source end, the results show that the measured beam current is 40.3 mA, the beam diameter is less than 5 cm and the RMS normalized emittance is less than 0.2 pi mm-mrad. In addition, The variation of beam current has been studied as a function of the extraction voltage, gas pressure, and arc current. The variation of RMS normalized emittance of the proton beam has been studied as a function of extraction voltage and arc current. In addition, the results show that the measured beam current is 28.5 mA, the beam diameter is around 0.7 cm and the RMS normalized emittance is 0.3 pi mm-mrad after focusing at the LEBT end.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] ION BEAM CONTROL IN A DUOPLASMATRON SOURCE
    COLLINS, LE
    BROOKER, RJ
    NUCLEAR INSTRUMENTS & METHODS, 1962, 15 (02): : 193 - 196
  • [2] Proton beam simulation of duoplasmatron ion source for diagnostic neutral beam of Alborz tokamak
    Kazemi, M.
    Amrollahi, R.
    FUSION ENGINEERING AND DESIGN, 2018, 127 : 1 - 9
  • [3] Experimental optimization of beam quality extracted from a duoplasmatron proton ion source
    Batygin, Y.K.
    Draganic, I.N.
    Fortgang, C.M.
    Review of Scientific Instruments, 2014, 85 (10):
  • [4] STUDY OF A FOCUSED BEAM FROM DUOPLASMATRON PROTON SOURCE
    MCKEEVER, R
    YOKOSAWA, A
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1962, 33 (07): : 746 - &
  • [5] Design and optimization study of a duoplasmatron ion source for high-intensity proton beam
    Zhou, Bowen
    Zhang, Hong
    Zhang, Pengjiao
    Li, Wenliang
    An, Sun
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 1010
  • [6] DUOPLASMATRON ION BEAM SOURCE FOR VACUUM SPUTTERING OF THIN FILMS
    CHOPRA, KL
    RANDLETT, MR
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1967, 38 (08): : 1147 - &
  • [7] SOME PROPERTIES OF ION BEAM FROM A SOURCE OF DUOPLASMATRON TYPE
    SEPTIER, A
    PRANGERE, F
    ISMAIL, H
    GAUTHERI.G
    NUCLEAR INSTRUMENTS & METHODS, 1965, 38 (DEC): : 41 - &
  • [8] Duoplasmatron ion source for proton and deuteron intense beams at low energy
    Marinescu, L
    Dima, R
    Dobrescu, S
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (03): : 1356 - 1356
  • [9] PRODUCTION OF H- ION-BEAM USING DUOPLASMATRON SOURCE
    ROY, NR
    CURRENT SCIENCE, 1984, 53 (08): : 421 - 423
  • [10] Operating characteristics of duoplasmatron ion source
    College of Instrumentation and Electrical Engineering, Jilin University, Changchun
    130022, China
    不详
    100037, China
    Jilin Daxue Xuebao (Gongxueban), 1 (161-166):