Gated blood pool SPECT for measurement of left ventricular volumes and left ventricular ejection fraction: comparison of 8 and 16 frame gated blood pool SPECT

被引:0
|
作者
Seong-Jang Kim
In-Ju Kim
Yun-Seong Kim
Yong-Ki Kim
机构
[1] Pusan National University Hospital,Department of Nuclear Medicine
[2] Pusan National University Hospital,Department of Internal Medicine
关键词
end-diastolic volume; end-systolic volume; gated blood pool SPECT; 8 and 16 frame; left ventricular ejection fraction;
D O I
暂无
中图分类号
学科分类号
摘要
Gated blood pool SPECT (GBPS) is an alternative to planar radionuclide ventriculography (PRNV) and offers potential advantages. The aim of this study was to compare 8 and 16 frame GBPS for the determination of left ventricular ejection fraction(LVEF) and left ventricular volumes (LV) in subjects underwent two consecutive GBPS. Method: About 66 consecutive patients (30 men, 36 women; mean age 62.3 ± 10.4 years) referred for PRNV for evaluation of preoperative cardiac risk stratification (n=40), prechemotherapy cardiac function evaluation (n=18, breast cancer), and congestive heart failure patients (n=8). All patients underwent PRNV of 16 frame and GBPS with both of 8 and 16 frame. Results: The mean LVEF calculated with PRNV (58.3 ± 16.8), showed statistically lower than 8-GBPS (70.6 ± 17.7), and 16-GBPS (69.9 ± 16.8) (PRNV vs. 8-GBPS, p < 0.01; PRNV vs 16-GBPS, p < 0.01; 8-GBPS vs 16-GBPS, p > 0.05). The correlation of LVEFS between 8-GBPS and 16-GBPS showed a correlation coefficient of 0.9194 (p < 0.01, 95% CI=0.8712–0.9500). The mean left ventricular end-diastolic volumes (EDV) calculated with 8-GBPS (83.2 ± 33.5 ml), and 16-GBPS (88.4 ± 36.8 ml) showed no statistical differences (p > 0.05). The mean left ventricular end-systolic volumes (ESV) calculated with 8-GBPS (28.1 ± 31.4 ml), and 16-GBPS (30.5 ± 33 ml) showed also no statistical differences (p > 0.05). Comparison of EDV from 8 and 16-GBPS yielded a correlation coefficient of 0.7430 (p < 0.01, 95% CI=0.6108-0.8349). The correlation between ESV of 8-GBPS and 16-GBPS showed a correlation coefficient of 0.9522 (p < 0.01, 95% CI=0.9228–0.9705). Conclusion: This study demonstrated that the LVEFs of 8-GBPS correlated well with that of 16-GBPS. The LVEF of PRNV was significantly lower than those of 8 and 16-GBPS. Also, left ventricular EDV and ESV of 8-GBPS correlated well with those of 16-GBPS. Also, further studies, involving large lumber patients, should be performed to validate the usefulness of GBPS for the evaluation of left ventricular diastolic function.
引用
收藏
页码:261 / 266
页数:5
相关论文
共 50 条
  • [31] Is 16-frame really superior to 8-frame gated SPECT for the assessment of left ventricular volumes and ejection fraction? Comparison of two simultaneously acquired gated SPECT studies
    Montelatici, Giulia
    Sciagra, Roberto
    Passeri, Alessandro
    Dona, Manjola
    Pupi, Alberto
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (11) : 2059 - 2065
  • [32] Quantification of left ventricular volumes and ejection fraction by gated SPECT in patients with left ventricular aneurysm: Comparison with MRI
    Tian, Congna
    Lu, Minjie
    Wei, HongXing
    Tian, Yueqin
    Zhao, Shihua
    Zhang, Xiaoli
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [33] Left Ventricular Ejection Fraction in gated blood pool imaging: sources of variation
    Knudsen, K.
    Arveschoug, A. K.
    Staanum, P. F.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S376 - S376
  • [34] Evaluation of Left and Right Ventricular Ejection Fraction and Volumes from Gated Blood-Pool SPECT in Patients with Dilated Cardiomyopathy: Comparison with Cardiac MRI
    Xie, Bo-Qia
    Tian, Yue-Qin
    Zhang, Jian
    Zhao, Shi-Hua
    Yang, Min-Fu
    Guo, Feng
    Wang, Dao-Yu
    Wei, Hong-Xing
    Chu, Ke-Wei
    He, Zuo-Xiang
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (04) : 584 - 591
  • [35] Gated myocardial perfusion tomography versus gated blood pool tomography for the calculation of left ventricular volumes and ejection fraction
    Vanhove, C
    Walgraeve, N
    De Geeter, F
    Franken, PR
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (06) : 735 - 741
  • [36] Gated myocardial perfusion tomography versus gated blood pool tomography for the calculation of left ventricular volumes and ejection fraction
    Christian Vanhove
    Natasha Walgraeve
    Frank De Geeter
    Philippe R. Franken
    European Journal of Nuclear Medicine and Molecular Imaging, 2002, 29 : 735 - 741
  • [37] Left ventricular ejection fraction and gated SPECT - Reply
    Germano, G
    Berman, DS
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (06) : 1121 - 1122
  • [38] Left ventricular volumes and ejection fraction obtained from 16-frame gated SPECT versus 8-frame gated SPECT in comparison with echocardiography: influence of different processing softwares
    Yapar, Z.
    Kibar, M.
    Tasal, A.
    Bozkurt, A.
    Nursal, N.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S250 - S250
  • [39] Attenuation corrected gated SPECT for the assessment of left ventricular ejection fraction and volumes
    Riemer H. J. A. Slart
    René A. Tio
    Clark J. Zeebregts
    Antoon T. M. Willemsen
    Rudi A. J. O. Dierckx
    Johan De Sutter
    Annals of Nuclear Medicine, 2008, 22 : 171 - 176
  • [40] Left ventricular ejection fraction and volumes from gated blood pool tomographies: A comparison between two automatic algorithms
    Vanhove, C
    Walgraeve, N
    Everaert, H
    Franken, PR
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (08): : 1038 - 1038