Gated blood pool SPECT for measurement of left ventricular volumes and left ventricular ejection fraction: comparison of 8 and 16 frame gated blood pool SPECT

被引:0
|
作者
Seong-Jang Kim
In-Ju Kim
Yun-Seong Kim
Yong-Ki Kim
机构
[1] Pusan National University Hospital,Department of Nuclear Medicine
[2] Pusan National University Hospital,Department of Internal Medicine
关键词
end-diastolic volume; end-systolic volume; gated blood pool SPECT; 8 and 16 frame; left ventricular ejection fraction;
D O I
暂无
中图分类号
学科分类号
摘要
Gated blood pool SPECT (GBPS) is an alternative to planar radionuclide ventriculography (PRNV) and offers potential advantages. The aim of this study was to compare 8 and 16 frame GBPS for the determination of left ventricular ejection fraction(LVEF) and left ventricular volumes (LV) in subjects underwent two consecutive GBPS. Method: About 66 consecutive patients (30 men, 36 women; mean age 62.3 ± 10.4 years) referred for PRNV for evaluation of preoperative cardiac risk stratification (n=40), prechemotherapy cardiac function evaluation (n=18, breast cancer), and congestive heart failure patients (n=8). All patients underwent PRNV of 16 frame and GBPS with both of 8 and 16 frame. Results: The mean LVEF calculated with PRNV (58.3 ± 16.8), showed statistically lower than 8-GBPS (70.6 ± 17.7), and 16-GBPS (69.9 ± 16.8) (PRNV vs. 8-GBPS, p < 0.01; PRNV vs 16-GBPS, p < 0.01; 8-GBPS vs 16-GBPS, p > 0.05). The correlation of LVEFS between 8-GBPS and 16-GBPS showed a correlation coefficient of 0.9194 (p < 0.01, 95% CI=0.8712–0.9500). The mean left ventricular end-diastolic volumes (EDV) calculated with 8-GBPS (83.2 ± 33.5 ml), and 16-GBPS (88.4 ± 36.8 ml) showed no statistical differences (p > 0.05). The mean left ventricular end-systolic volumes (ESV) calculated with 8-GBPS (28.1 ± 31.4 ml), and 16-GBPS (30.5 ± 33 ml) showed also no statistical differences (p > 0.05). Comparison of EDV from 8 and 16-GBPS yielded a correlation coefficient of 0.7430 (p < 0.01, 95% CI=0.6108-0.8349). The correlation between ESV of 8-GBPS and 16-GBPS showed a correlation coefficient of 0.9522 (p < 0.01, 95% CI=0.9228–0.9705). Conclusion: This study demonstrated that the LVEFs of 8-GBPS correlated well with that of 16-GBPS. The LVEF of PRNV was significantly lower than those of 8 and 16-GBPS. Also, left ventricular EDV and ESV of 8-GBPS correlated well with those of 16-GBPS. Also, further studies, involving large lumber patients, should be performed to validate the usefulness of GBPS for the evaluation of left ventricular diastolic function.
引用
收藏
页码:261 / 266
页数:5
相关论文
共 50 条
  • [41] Attenuation corrected gated SPECT for the assessment of left ventricular ejection fraction and volumes
    Slart, Riemer H. J. A.
    Tio, Rene A.
    Zeebregts, Clark J.
    Willemsen, Antoon T. M.
    Dierckx, Rudi A. J. O.
    De Sutter, Johan
    ANNALS OF NUCLEAR MEDICINE, 2008, 22 (03) : 171 - 176
  • [42] Validation of Gated Blood-Pool SPECT Regional Left Ventricular Function Measurements
    Nichols, Kenneth J.
    Van Tosh, Andrew
    Wang, Yi
    Palestro, Christopher J.
    Reichek, Nathaniel
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (01) : 53 - 60
  • [43] Initial experience of assessment of left ventricular function with gated blood pool SPECT in Kuwait
    Biswas, G.
    Panchadar, S.
    Mohammad, Y.
    Syed, M.
    Mohammad, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S334 - S334
  • [44] Left ventricular ejection fraction computed from gated SPECT blood pool imaging correlates with conventional planar imaging.
    Groch, MW
    Marshall, RC
    Erwin, WD
    Spies, SM
    Barnett, CA
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 98P - 98P
  • [45] Accuracy of TOMPOOL (gated blood pool SPECT processing software) for the assessment of bi-ventricular volumes and ejection fraction
    Dercle, L.
    Pascal, P.
    Giraudmaillet, T.
    Ouali, M.
    Lairez, O.
    Marachet, M. -A.
    Rousseau, H.
    Sinigaglia, M.
    Aziz, A. -L.
    Bastie, D.
    Berry, I.
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2015, 39 (04): : 371 - 379
  • [46] Comparison of gated blood-pool SPECT using CZT camera and M-mode echocardiogram for left ventricular ejection fraction estimation
    Chen, Yi-Chieh
    Ko, Chi-Lun
    Huang, Yih-Hwen
    Cheng, Mei-Fang
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [47] Automatic determination of LV ejection fraction and volumes by gated blood pool SPECT.
    Vanhove, C
    Everaert, H
    Bossuyt, A
    Franken, PR
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 187P - 187P
  • [48] Evaluation of left and right ventricular ejection fraction and volumes from gated blood-pool SPECT in patients with dilated cardiomyopathy comparison with cardiac magnetic resonance imaging
    Xie, Bo-Qia
    Tian, Yue-Qin
    Zhang, Jian
    Kang, Lian-Ming
    Zhao, Shi-Hua
    Lu, Min-Jie
    Yang, Min-Fu
    Wang, Dao-Yu
    Guo, Feng
    He, Zuo-Xiang
    CARDIOLOGY, 2011, 120 : 60 - 60
  • [49] A prospective evaluation of the repeatability of left ventricular ejection fraction measurement by gated SPECT
    Kliner, Dustin
    Wang, Li
    Winger, Daniel
    Follansbee, William P.
    Soman, Prem
    JOURNAL OF NUCLEAR CARDIOLOGY, 2015, 22 (06) : 1237 - 1243
  • [50] A prospective evaluation of the repeatability of left ventricular ejection fraction measurement by gated SPECT
    Dustin Kliner
    Li Wang
    Daniel Winger
    William P. Follansbee
    Prem Soman
    Journal of Nuclear Cardiology, 2015, 22 : 1237 - 1243