Evaluation of Left and Right Ventricular Ejection Fraction and Volumes from Gated Blood-Pool SPECT in Patients with Dilated Cardiomyopathy: Comparison with Cardiac MRI

被引:30
|
作者
Xie, Bo-Qia [1 ,2 ,3 ,4 ]
Tian, Yue-Qin [1 ,2 ,3 ,4 ]
Zhang, Jian [5 ,6 ]
Zhao, Shi-Hua [7 ,8 ]
Yang, Min-Fu [1 ,2 ,3 ,4 ]
Guo, Feng [1 ,2 ,3 ,4 ]
Wang, Dao-Yu [1 ,2 ,3 ,4 ]
Wei, Hong-Xing [1 ,2 ,3 ,4 ]
Chu, Ke-Wei [1 ,2 ,3 ,4 ]
He, Zuo-Xiang [1 ,2 ,3 ,4 ]
机构
[1] Chinese Acad Med Sci, Cardiovasc Inst, Dept Nucl Med, Beijing 100037, Peoples R China
[2] Peking Union Med Coll, Cardiovasc Inst, Dept Nucl Med, Beijing 100037, Peoples R China
[3] Peking Union Med Coll, Fu Wai Hosp, Beijing 100037, Peoples R China
[4] Chinese Acad Med Sci, Fu Wai Hosp, Beijing 100037, Peoples R China
[5] Chinese Acad Med Sci, Cardiovasc Inst, Heart Failure Care Unit, Beijing 100037, Peoples R China
[6] Peking Union Med Coll, Cardiovasc Inst, Heart Failure Care Unit, Beijing 100037, Peoples R China
[7] Chinese Acad Med Sci, Cardiovascular Inst, Dept Radiol, Beijing 100037, Peoples R China
[8] Peking Union Med Coll, Cardiovascular Inst, Dept Radiol, Beijing 100037, Peoples R China
基金
美国国家科学基金会;
关键词
dilated cardiomyopathy; gated blood-pool SPECT; cardiac magnetic resonance imaging; ventricular function; AUTOMATIC QUANTIFICATION; MAGNETIC-RESONANCE; HEART-FAILURE; SURVIVAL; VALIDATION; DIAGNOSIS; CMR;
D O I
10.2967/jnumed.111.096057
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This prospective study evaluated the accuracy of electrocardiogram-gated blood-pool SPECT (GBPS) for the assessment of left ventricular (LV) and right ventricular (RV) ejection fraction (EF), end-diastolic volume (EDV), and end-systolic volume (ESV) in patients with dilated cardiomyopathy (DCM), using cardiac magnetic resonance (CMR) imaging as the reference standard. Methods: Thirty-two patients (24 men and 8 women; mean age, 51 y) with a diagnosis of idiopathic DCM underwent GBPS and CMR. LV and RV parameters including EDV, ESV, and EF from GBPS were calculated using fully automated gradient software and compared with those obtained by CMR. Results: Biventricular volumes were underestimated by GBPS, compared with CMR (P < 0.001). We found no statistical difference between these 2 methods in the assessment of LV EF (P = 0.23), whereas RV EF was overestimated by GBPS (P < 0.001 vs. CMR). Regression analysis yielded significant correlations between GBPS and CMR in the assessments of biventricular parameters (r = 0.83 for LV EDV, 0.88 for LV ESV, 0.89 for LV EF, 0.86 for RV EDV, 0.86 for RV ESV, and 0.62 for RV EF; all P < 0.001). Comparison of the deviations of RV indices between GBPS and CMR with the ratio of RV EDV to LV EDV showed that there was a statistically significant trend for RV volumes to be underestimated and for RV EF to be overestimated as the biventricular volumetric ratio decreased (r = 0.61 for RV EDV, 0.68 for RV ESV, and -0.55 for RV EF; all P < 0.001). Conclusion: For patients with DCM, GBPS correlated well with CM R for the assessment of biventricular parameters, but RV indices should be cautiously interpreted. Key Words: dilated cardiomyopathy; gated blood-pool SPECT; cardiac magnetic resonance imaging; ventricular function
引用
收藏
页码:584 / 591
页数:8
相关论文
共 50 条
  • [1] Evaluation of left and right ventricular ejection fraction and volumes from gated blood-pool SPECT in patients with dilated cardiomyopathy comparison with cardiac magnetic resonance imaging
    Xie, Bo-Qia
    Tian, Yue-Qin
    Zhang, Jian
    Kang, Lian-Ming
    Zhao, Shi-Hua
    Lu, Min-Jie
    Yang, Min-Fu
    Wang, Dao-Yu
    Guo, Feng
    He, Zuo-Xiang
    CARDIOLOGY, 2011, 120 : 60 - 60
  • [2] Evaluation of left ventricular volumes and ejection fraction by gated SPECT and cardiac MRI in patients with dilated cardiomyopathy
    Feng Wang
    Jian Zhang
    Wei Fang
    Shi-Hua Zhao
    Min-Jie Lu
    Zuo-Xiang He
    European Journal of Nuclear Medicine and Molecular Imaging, 2009, 36 : 1611 - 1621
  • [3] Evaluation of left ventricular volumes and ejection fraction by gated SPECT and cardiac MRI in patients with dilated cardiomyopathy
    Wang, Feng
    Zhang, Jian
    Fang, Wei
    Zhao, Shi-Hua
    Lu, Min-Jie
    He, Zuo-Xiang
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 (10) : 1611 - 1621
  • [4] Left ventricular ejection fraction and volumes from gated blood-pool SPECT: Comparison with planar gated blood-pool imaging and assessment of repeatability in patients with heart failure
    Wright, GA
    Thackray, S
    Howey, S
    Cleland, JG
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (04) : 494 - 498
  • [5] Gated blood-pool SPECT versus cardiac magnetic resonance imaging for the assessment of left ventricular volumes and ejection fraction
    Harel, Francois
    Finnerty, Vincent
    Gregoire, Jean
    Thibault, Bernard
    Marcotte, Francois
    Ugolini, Patricia
    Khairy, Paul
    JOURNAL OF NUCLEAR CARDIOLOGY, 2010, 17 (03) : 427 - 434
  • [6] Gated blood-pool SPECT versus cardiac magnetic resonance imaging for the assessment of left ventricular volumes and ejection fraction
    François Harel
    Vincent Finnerty
    Jean Grégoire
    Bernard Thibault
    François Marcotte
    Patricia Ugolini
    Paul Khairy
    Journal of Nuclear Cardiology, 2010, 17 : 427 - 434
  • [7] Left ventricular ejection fraction: Comparison of results from planar and SPECT gated blood-pool studies
    Bartlett, ML
    Srinivasan, G
    Barker, WC
    Kitsiou, AN
    Dilsizian, V
    Bacharach, SL
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (11) : 1795 - 1799
  • [8] Comparison of Gated Blood Pool SPECT with cardiac ultrasound for quantification of left ventricular volumes and ejection fraction.
    Bugriy, M.
    Rogunova, N.
    Saidova, M.
    Sergienko, V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S311 - S311
  • [9] Gated blood pool SPECT for measurement of left ventricular volumes and left ventricular ejection fraction: comparison of 8 and 16 frame gated blood pool SPECT
    Seong-Jang Kim
    In-Ju Kim
    Yun-Seong Kim
    Yong-Ki Kim
    The International Journal of Cardiovascular Imaging, 2005, 21 : 261 - 266
  • [10] Gated blood pool SPECT for measurement of left ventricular volumes and left ventricular ejection fraction: comparison of 8 and 16 frame gated blood pool SPECT
    Kim, SJ
    Kim, IJ
    Kim, YS
    Kim, YK
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2005, 21 (2-3): : 261 - 266