摘要
Gated blood pool SPECT (GBPS) is an alternative to planar radionuclide ventriculography (PRNV) and offers potential advantages. The aim of this study was to compare 8 and 16 frame GBPS for the determination of left ventricular ejection fraction(LVEF) and left ventricular volumes (LV) in subjects underwent two consecutive GBPS. Method: About 66 consecutive patients (30 men, 36 women; mean age 62.3 ± 10.4 years) referred for PRNV for evaluation of preoperative cardiac risk stratification (n=40), prechemotherapy cardiac function evaluation (n=18, breast cancer), and congestive heart failure patients (n=8). All patients underwent PRNV of 16 frame and GBPS with both of 8 and 16 frame. Results: The mean LVEF calculated with PRNV (58.3 ± 16.8), showed statistically lower than 8-GBPS (70.6 ± 17.7), and 16-GBPS (69.9 ± 16.8) (PRNV vs. 8-GBPS, p < 0.01; PRNV vs 16-GBPS, p < 0.01; 8-GBPS vs 16-GBPS, p > 0.05). The correlation of LVEFS between 8-GBPS and 16-GBPS showed a correlation coefficient of 0.9194 (p < 0.01, 95% CI=0.8712–0.9500). The mean left ventricular end-diastolic volumes (EDV) calculated with 8-GBPS (83.2 ± 33.5 ml), and 16-GBPS (88.4 ± 36.8 ml) showed no statistical differences (p > 0.05). The mean left ventricular end-systolic volumes (ESV) calculated with 8-GBPS (28.1 ± 31.4 ml), and 16-GBPS (30.5 ± 33 ml) showed also no statistical differences (p > 0.05). Comparison of EDV from 8 and 16-GBPS yielded a correlation coefficient of 0.7430 (p < 0.01, 95% CI=0.6108-0.8349). The correlation between ESV of 8-GBPS and 16-GBPS showed a correlation coefficient of 0.9522 (p < 0.01, 95% CI=0.9228–0.9705). Conclusion: This study demonstrated that the LVEFs of 8-GBPS correlated well with that of 16-GBPS. The LVEF of PRNV was significantly lower than those of 8 and 16-GBPS. Also, left ventricular EDV and ESV of 8-GBPS correlated well with those of 16-GBPS. Also, further studies, involving large lumber patients, should be performed to validate the usefulness of GBPS for the evaluation of left ventricular diastolic function.
引用
收藏
页码:261 / 266
页数:5
相关论文
共 50 条
  • [1] Gated blood pool SPECT for measurement of left ventricular volumes and left ventricular ejection fraction: comparison of 8 and 16 frame gated blood pool SPECT
    Kim, SJ
    Kim, IJ
    Kim, YS
    Kim, YK
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2005, 21 (2-3): : 261 - 266
  • [2] Left ventricular ejection fraction: Gated blood pool SPECT versus myocardial perfusion gated SPECT.
    Daou, D
    Coaguila, C
    Vilain, D
    Lebtahi, R
    Benelhadj, S
    Fourme, T
    Colin, P
    Idy-Peretti, I
    Slama, M
    Le Guludec, D
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 97P - 97P
  • [3] Comparison of Gated Blood Pool SPECT with cardiac ultrasound for quantification of left ventricular volumes and ejection fraction.
    Bugriy, M.
    Rogunova, N.
    Saidova, M.
    Sergienko, V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S311 - S311
  • [4] Left and right ventricular volumes and ejection fraction in mice using ECG gated pinhole gated blood pool SPECT
    Lahoutte, T
    Vanhove, C
    Bossuyt, A
    Franken, PR
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S260 - S260
  • [5] Automatic quantification of left ventricular ejection fraction from gated blood pool SPECT
    Serge D. Van Kriekinge
    Daniel S. Berman
    Guido Germano
    Journal of Nuclear Cardiology, 1999, 6 : 498 - 506
  • [6] Automatic quantification of left ventricular ejection fraction from gated blood pool SPECT
    Van Kriekinge, SD
    Berman, DS
    Germano, G
    JOURNAL OF NUCLEAR CARDIOLOGY, 1999, 6 (05) : 498 - 506
  • [7] Automatic quantification of left ventricular ejection fraction from gated blood pool SPECT
    vanKriekinge, SD
    Berman, DS
    Germano, G
    CIRCULATION, 1997, 96 (08) : 1725 - 1725
  • [8] Automatic quantification of right ventricular volumes and right ventricular ejection fraction with gated blood pool SPECT: Comparison of 8- and 16-frame gated blood pool SPECT with first-pass radionuclide angiography
    Seong-Jang Kim
    In-Ju Kim
    Yun-Seong Kim
    Yong-Ki Kim
    Yong Beom Shin
    Dong-Soo Kim
    Journal of Nuclear Cardiology, 2005, 12 : 553 - 559
  • [9] Automatic quantification of right ventricular volumes and right ventricular ejection fraction with gated blood pool SPECT: Comparison of 8- and 16-frame gated blood pool SPECT with first-pass radionuclide angiography
    Kim, SJ
    Kim, IJ
    Kim, YS
    Kim, YK
    Shin, YB
    Kim, DS
    JOURNAL OF NUCLEAR CARDIOLOGY, 2005, 12 (05) : 553 - 559
  • [10] Left ventricular ejection fraction: Comparison of results from planar and SPECT gated blood-pool studies
    Bartlett, ML
    Srinivasan, G
    Barker, WC
    Kitsiou, AN
    Dilsizian, V
    Bacharach, SL
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (11) : 1795 - 1799