Thermodynamic-based retention time predictions of endogenous steroids in comprehensive two-dimensional gas chromatography

被引:0
|
作者
Aline C. A. Silva
Heshmatollah Ebrahimi-Najafadabi
Teague M. McGinitie
Alessandro Casilli
Henrique M. G. Pereira
Francisco R. Aquino Neto
James J. Harynuk
机构
[1] Universidade Federal do Rio de Janeiro,Instituto de Química
[2] University of Alberta,Department of Chemistry
[3] Guilan University of Medical Sciences,Department of Medicinal Chemistry, School of Pharmacy
来源
关键词
Doping control; Two-dimensional gas chromatography–time-of-flight mass spectrometry; Thermodynamics; Retention time prediction; Endogenous steroids;
D O I
暂无
中图分类号
学科分类号
摘要
This work evaluates the application of a thermodynamic model to comprehensive two-dimensional gas chromatography (GC × GC) coupled with time-of-flight mass spectrometry for anabolic agent investigation. Doping control deals with hundreds of drugs that are prohibited in sports. Drug discovery in biological matrices is a challenging task that requires powerful tools when one is faced with the rapidly changing designer drug landscape. In this work, a thermodynamic model developed for the prediction of both primary and secondary retention times in GC × GC has been applied to trimethylsilylated hydroxyl (O-TMS)- and methoxime-trimethylsilylated carbonyl (MO-TMS)-derivatized endogenous steroids. This model was previously demonstrated on a pneumatically modulated GC × GC system, and is applied for the first time to a thermally modulated GC × GC system. Preliminary one-dimensional experiments allowed the calculation of thermodynamic parameters (ΔH, ΔS, and ΔCp) which were successfully applied for the prediction of the analytes’ interactions with the stationary phases of both the first-dimension column and the second-dimension column. The model was able to predict both first-dimension and second-dimension retention times with high accuracy compared with the GC × GC experimental measurements. Maximum differences of -8.22 s in the first dimension and 0.4 s in the second dimension were encountered for the O-TMS derivatives of 11β-hydroxyandrosterone and 11-ketoetiocholanolone, respectively. For the MO-TMS derivatives, the largest discrepancies were from testosterone (9.65 s) for the first-dimension retention times and 11-keto-etiocholanolone (0.4 s) for the second-dimension retention times.
引用
收藏
页码:4091 / 4099
页数:8
相关论文
共 50 条
  • [21] Predictions of comprehensive two-dimensional gas chromatography separations from isothermal data
    Zhu, Shukui
    He, Sheng
    Worton, David R.
    Goldstein, Allen H.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2012, 1233 : 147 - 151
  • [22] Retention-time prediction in comprehensive two-dimensional gas chromatography to aid identification of unknown contaminants
    Veenaas, Cathrin
    Linusson, Anna
    Haglund, Peter
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (30) : 7931 - 7941
  • [23] Retention time reproducibility in comprehensive two-dimensional gas chromatography using cryogenic modulation - An intralaboratory study
    Shellie, RA
    Xie, LL
    Marriott, PJ
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2002, 968 (1-2) : 161 - 170
  • [24] Retention-time prediction in comprehensive two-dimensional gas chromatography to aid identification of unknown contaminants
    Cathrin Veenaas
    Anna Linusson
    Peter Haglund
    [J]. Analytical and Bioanalytical Chemistry, 2018, 410 : 7931 - 7941
  • [25] Retention modeling and retention time prediction in gas chromatography and flow-modulation comprehensive two-dimensional gas chromatography: The contribution of pressure on solute partition
    Burel, Antoine
    Vaccaro, Marie
    Cartigny, Yohann
    Tisse, Severine
    Coquerel, Gerard
    Cardinael, Pascal
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2017, 1485 : 101 - 119
  • [26] Reproducibility of retention time and peak area in comprehensive two-dimensional liquid chromatography
    Victoria Elsner
    Volker Wulf
    Michaela Wirtz
    Oliver J. Schmitz
    [J]. Analytical and Bioanalytical Chemistry, 2015, 407 : 279 - 284
  • [27] Reproducibility of retention time and peak area in comprehensive two-dimensional liquid chromatography
    Elsner, Victoria
    Wulf, Volker
    Wirtz, Michaela
    Schmitz, Oliver J.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (01) : 279 - 284
  • [28] Retention time prediction in thermally modulated comprehensive two-dimensional gas chromatography: Correcting second dimension retention time modeling error
    Jaramillo, Roman
    Dorman, Frank L.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2018, 1581 : 116 - 124
  • [29] Multidimensional and comprehensive - Two-dimensional gas chromatography
    Marriott, PJ
    Morrison, PD
    Shellie, RA
    Dunn, MS
    Sari, E
    Ryan, D
    [J]. LC GC EUROPE, 2003, 16 (12A) : 23 - 31
  • [30] Restoration for comprehensive two-dimensional gas chromatography
    Shi, Jiazheng
    Reichenbach, Stephen E.
    [J]. 2005 IEEE INTERNATIONAL CONFERENCE ON ELECTRO/INFORMATION TECHNOLOGY (EIT 2005), 2005, : 512 - 517