Retention-time prediction in comprehensive two-dimensional gas chromatography to aid identification of unknown contaminants

被引:24
|
作者
Veenaas, Cathrin [1 ]
Linusson, Anna [1 ]
Haglund, Peter [1 ]
机构
[1] Umea Univ, Dept Chem, S-90187 Umea, Sweden
关键词
GCxGC; Retention-time prediction; Partial least squares (PLS); Federation of local models; Quantitative structure-retention relationship (QSRR); Non-target analysis; LIQUID-CHROMATOGRAPHY; MASS-SPECTROMETRY; INDEX SYSTEM; MODEL; SEPARATIONS;
D O I
10.1007/s00216-018-1415-x
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Comprehensive two-dimensional (2D) gas chromatography (GCxGC) coupled to mass spectrometry (MS, GCxGC-MS), which enhances selectivity compared to GC-MS analysis, can be used for non-directed analysis (non-target screening) of environmental samples. Additional tools that aid in identifying unknown compounds are needed to handle the large amount of data generated. These tools include retention indices for characterizing relative retention of compounds and prediction of such. In this study, two quantitative structure-retention relationship (QSRR) approaches for prediction of retention times ((1)t(R) and (2)t(R)) and indices (linear retention indices (LRIs) and a new polyethylene glycol-based retention index (PEG-I-2)) in GCxGC were explored, and their predictive power compared. In the first method, molecular descriptors combined with partial least squares (PLS) analysis were used to predict times and indices. In the second method, the commercial software package ChromGenius (ACD/Labs), based on a federation of local models, was employed. Overall, the PLS approach exhibited better accuracy than the ChromGenius approach. Although average errors for the LRI prediction via ChromGenius were slightly lower, PLS was superior in all other cases. The average deviations between the predicted and the experimental value were 5% and 3% for the (1)t(R) and LRI, and 5% and 12% for the (2)t(R) and PEG-I-2, respectively. These results are comparable to or better than those reported in previous studies. Finally, the developed model was successfully applied to an independent dataset and led to the discovery of 12 wrongly assigned compounds. The results of the present work represent the first-ever prediction of the PEG-I-2.
引用
收藏
页码:7931 / 7941
页数:11
相关论文
共 50 条
  • [1] Retention-time prediction in comprehensive two-dimensional gas chromatography to aid identification of unknown contaminants
    Cathrin Veenaas
    Anna Linusson
    Peter Haglund
    Analytical and Bioanalytical Chemistry, 2018, 410 : 7931 - 7941
  • [2] Identification of unknown compounds on the basis of retention index data in comprehensive two-dimensional gas chromatography
    Pang, Tao
    Zhu, Shukui
    Lu, Xin
    Xu, Guowang
    JOURNAL OF SEPARATION SCIENCE, 2007, 30 (06) : 868 - 874
  • [3] Retention time locking procedure for comprehensive two-dimensional gas chromatography
    Mommers, John
    Knooren, Jeroen
    Mengerink, Ynze
    Wilbers, Arno
    Vreuls, Rene
    van der Wal, Sjoerd
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (21) : 3159 - 3165
  • [4] Two-Dimensional Retention Indices Improve Component Identification in Comprehensive Two-Dimensional Gas Chromatography of Saffron
    Jiang, Ming
    Kulsing, Chadin
    Nolvachai, Yada
    Marriott, Philip J.
    ANALYTICAL CHEMISTRY, 2015, 87 (11) : 5753 - 5761
  • [5] Retention indices in comprehensive two-dimensional gas chromatography
    von Muehlen, Carin
    Marriott, Philip J.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 401 (08) : 2351 - 2360
  • [6] Retention indices in comprehensive two-dimensional gas chromatography
    Carin von Mühlen
    Philip J. Marriott
    Analytical and Bioanalytical Chemistry, 2011, 401 : 2351 - 2360
  • [7] Retention modeling and retention time prediction in gas chromatography and flow-modulation comprehensive two-dimensional gas chromatography: The contribution of pressure on solute partition
    Burel, Antoine
    Vaccaro, Marie
    Cartigny, Yohann
    Tisse, Severine
    Coquerel, Gerard
    Cardinael, Pascal
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1485 : 101 - 119
  • [8] Prediction of retention times in comprehensive two-dimensional gas chromatography using thermodynamic models
    McGinitie, Teague M.
    Harynuk, James J.
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1255 : 184 - 189
  • [9] Retention time prediction in thermally modulated comprehensive two-dimensional gas chromatography: Correcting second dimension retention time modeling error
    Jaramillo, Roman
    Dorman, Frank L.
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1581 : 116 - 124
  • [10] Evaluation of a retention model in comprehensive two-dimensional gas chromatography
    Vendeuvre, C
    Bertoncini, F
    Thiébaut, D
    Martin, M
    Hennion, MC
    JOURNAL OF SEPARATION SCIENCE, 2005, 28 (11) : 1129 - 1136