Retention-time prediction in comprehensive two-dimensional gas chromatography to aid identification of unknown contaminants

被引:24
|
作者
Veenaas, Cathrin [1 ]
Linusson, Anna [1 ]
Haglund, Peter [1 ]
机构
[1] Umea Univ, Dept Chem, S-90187 Umea, Sweden
关键词
GCxGC; Retention-time prediction; Partial least squares (PLS); Federation of local models; Quantitative structure-retention relationship (QSRR); Non-target analysis; LIQUID-CHROMATOGRAPHY; MASS-SPECTROMETRY; INDEX SYSTEM; MODEL; SEPARATIONS;
D O I
10.1007/s00216-018-1415-x
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Comprehensive two-dimensional (2D) gas chromatography (GCxGC) coupled to mass spectrometry (MS, GCxGC-MS), which enhances selectivity compared to GC-MS analysis, can be used for non-directed analysis (non-target screening) of environmental samples. Additional tools that aid in identifying unknown compounds are needed to handle the large amount of data generated. These tools include retention indices for characterizing relative retention of compounds and prediction of such. In this study, two quantitative structure-retention relationship (QSRR) approaches for prediction of retention times ((1)t(R) and (2)t(R)) and indices (linear retention indices (LRIs) and a new polyethylene glycol-based retention index (PEG-I-2)) in GCxGC were explored, and their predictive power compared. In the first method, molecular descriptors combined with partial least squares (PLS) analysis were used to predict times and indices. In the second method, the commercial software package ChromGenius (ACD/Labs), based on a federation of local models, was employed. Overall, the PLS approach exhibited better accuracy than the ChromGenius approach. Although average errors for the LRI prediction via ChromGenius were slightly lower, PLS was superior in all other cases. The average deviations between the predicted and the experimental value were 5% and 3% for the (1)t(R) and LRI, and 5% and 12% for the (2)t(R) and PEG-I-2, respectively. These results are comparable to or better than those reported in previous studies. Finally, the developed model was successfully applied to an independent dataset and led to the discovery of 12 wrongly assigned compounds. The results of the present work represent the first-ever prediction of the PEG-I-2.
引用
收藏
页码:7931 / 7941
页数:11
相关论文
共 50 条
  • [21] Comprehensive two-dimensional gas chromatography for the analysis of organohalogenated micro-contaminants
    Korytár, P
    Haglund, P
    de Boer, J
    Brinkman, UAT
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2006, 25 (04) : 373 - 396
  • [22] Comprehensive Two-Dimensional Gas Chromatography
    Ryan, Danielle
    Marriott, Philip
    ADVANCES IN CHROMATOGRAPHY, VOL 46, 2008, 46 : 451 - 467
  • [23] Comprehensive two-dimensional gas chromatography
    Hinshaw, JV
    LC GC EUROPE, 2004, 17 (02) : 86 - +
  • [24] Comprehensive two-dimensional gas chromatography
    Hinshaw, JV
    LC GC NORTH AMERICA, 2004, 22 (01) : 32 - +
  • [25] Comprehensive two-dimensional gas chromatography
    Ryan, D
    Marriott, P
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 376 (03) : 295 - 297
  • [26] Comprehensive two-dimensional gas chromatography
    Danielle Ryan
    Philip Marriott
    Analytical and Bioanalytical Chemistry, 2003, 376 : 295 - 297
  • [27] Retention time reproducibility in comprehensive two-dimensional gas chromatography using cryogenic modulation - An intralaboratory study
    Shellie, RA
    Xie, LL
    Marriott, PJ
    JOURNAL OF CHROMATOGRAPHY A, 2002, 968 (1-2) : 161 - 170
  • [28] Thermodynamic-based retention time predictions of endogenous steroids in comprehensive two-dimensional gas chromatography
    Silva, Aline C. A.
    Ebrahimi-Najafadabi, Heshmatollah
    McGinitie, Teague M.
    Casilli, Alessandro
    Pereira, Henrique M. G.
    Aquino Neto, Francisco R.
    Harynuk, James J.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (14) : 4091 - 4099
  • [29] Thermodynamic-based retention time predictions of endogenous steroids in comprehensive two-dimensional gas chromatography
    Aline C. A. Silva
    Heshmatollah Ebrahimi-Najafadabi
    Teague M. McGinitie
    Alessandro Casilli
    Henrique M. G. Pereira
    Francisco R. Aquino Neto
    James J. Harynuk
    Analytical and Bioanalytical Chemistry, 2015, 407 : 4091 - 4099
  • [30] Separation and identification of petroleum biomarkers by comprehensive two-dimensional gas chromatography
    Frysinger, GS
    Gaines, RB
    JOURNAL OF SEPARATION SCIENCE, 2001, 24 (02) : 87 - 96