Thermodynamic-based retention time predictions of endogenous steroids in comprehensive two-dimensional gas chromatography

被引:16
|
作者
Silva, Aline C. A. [1 ]
Ebrahimi-Najafadabi, Heshmatollah [3 ]
McGinitie, Teague M. [2 ]
Casilli, Alessandro [1 ]
Pereira, Henrique M. G. [1 ]
Aquino Neto, Francisco R. [1 ]
Harynuk, James J. [2 ]
机构
[1] Univ Fed Rio de Janeiro, Inst Quim, Ilha Fundao, BR-21941909 Rio De Janeiro, RJ, Brazil
[2] Univ Alberta, Dept Chem, Edmonton, AB T6G 2G2, Canada
[3] Guilan Univ Med Sci, Sch Pharm, Dept Med Chem, Rasht 4144656839, Iran
基金
加拿大自然科学与工程研究理事会;
关键词
Doping control; Two-dimensional gas chromatography-time-of-flight mass spectrometry; Thermodynamics; Retention time prediction; Endogenous steroids; SYSTEMATIC TOXICOLOGICAL ANALYSIS; LIQUID-CHROMATOGRAPHY; MASS-SPECTROMETRY; URINE SAMPLES; DRUGS; METABOLOMICS; METABOLITES; DISCOVERY;
D O I
10.1007/s00216-015-8627-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This work evaluates the application of a thermodynamic model to comprehensive two-dimensional gas chromatography (GC x GC) coupled with time-of-flight mass spectrometry for anabolic agent investigation. Doping control deals with hundreds of drugs that are prohibited in sports. Drug discovery in biological matrices is a challenging task that requires powerful tools when one is faced with the rapidly changing designer drug landscape. In this work, a thermodynamic model developed for the prediction of both primary and secondary retention times in GC x GC has been applied to trimethylsilylated hydroxyl (O-TMS)- and methoxime-trimethylsilylated carbonyl (MO-TMS)-derivatized endogenous steroids. This model was previously demonstrated on a pneumatically modulated GC x GC system, and is applied for the first time to a thermally modulated GC x GC system. Preliminary one-dimensional experiments allowed the calculation of thermodynamic parameters (Delta H, Delta S, and Delta C (p) ) which were successfully applied for the prediction of the analytes' interactions with the stationary phases of both the first-dimension column and the second-dimension column. The model was able to predict both first-dimension and second-dimension retention times with high accuracy compared with the GC x GC experimental measurements. Maximum differences of -8.22 s in the first dimension and 0.4 s in the second dimension were encountered for the O-TMS derivatives of 11 beta-hydroxyandrosterone and 11-ketoetiocholanolone, respectively. For the MO-TMS derivatives, the largest discrepancies were from testosterone (9.65 s) for the first-dimension retention times and 11-keto-etiocholanolone (0.4 s) for the second-dimension retention times.
引用
收藏
页码:4091 / 4099
页数:9
相关论文
共 50 条
  • [1] Thermodynamic-based retention time predictions of endogenous steroids in comprehensive two-dimensional gas chromatography
    Aline C. A. Silva
    Heshmatollah Ebrahimi-Najafadabi
    Teague M. McGinitie
    Alessandro Casilli
    Henrique M. G. Pereira
    Francisco R. Aquino Neto
    James J. Harynuk
    [J]. Analytical and Bioanalytical Chemistry, 2015, 407 : 4091 - 4099
  • [2] Retention time locking procedure for comprehensive two-dimensional gas chromatography
    Mommers, John
    Knooren, Jeroen
    Mengerink, Ynze
    Wilbers, Arno
    Vreuls, Rene
    van der Wal, Sjoerd
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (21) : 3159 - 3165
  • [3] Retention indices in comprehensive two-dimensional gas chromatography
    von Muehlen, Carin
    Marriott, Philip J.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 401 (08) : 2351 - 2360
  • [4] Retention indices in comprehensive two-dimensional gas chromatography
    Carin von Mühlen
    Philip J. Marriott
    [J]. Analytical and Bioanalytical Chemistry, 2011, 401 : 2351 - 2360
  • [5] Prediction of retention times in comprehensive two-dimensional gas chromatography using thermodynamic models
    McGinitie, Teague M.
    Harynuk, James J.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2012, 1255 : 184 - 189
  • [6] Evaluation of a retention model in comprehensive two-dimensional gas chromatography
    Vendeuvre, C
    Bertoncini, F
    Thiébaut, D
    Martin, M
    Hennion, MC
    [J]. JOURNAL OF SEPARATION SCIENCE, 2005, 28 (11) : 1129 - 1136
  • [7] Retention correlation maps in comprehensive two-dimensional gas chromatography
    Western, RJ
    Marriott, PJ
    [J]. JOURNAL OF SEPARATION SCIENCE, 2002, 25 (13) : 832 - 838
  • [8] A procedure for comprehensive two-dimensional gas chromatography retention time locked dual detection
    Mommers, John
    Ritzen, Erik
    Dutriez, Thomas
    van der Wal, Sjoerd
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2016, 1461 : 153 - 160
  • [9] Model for predicting comprehensive two-dimensional gas chromatography retention times
    Seeley, John V.
    Seeley, Stacy K.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1172 (01) : 72 - 83
  • [10] Molecular structure retention relationships in comprehensive two-dimensional gas chromatography