A procedure for comprehensive two-dimensional gas chromatography retention time locked dual detection

被引:12
|
作者
Mommers, John [1 ,2 ]
Ritzen, Erik [1 ]
Dutriez, Thomas [3 ]
van der Wal, Sjoerd [2 ]
机构
[1] DSM Resolve, POB 18, NL-6160 MD Geleen, Netherlands
[2] Univ Amsterdam, Vant Hoff Inst Mol Sci, Analyt Chem & Forens Anal Grp, Amsterdam, Netherlands
[3] Givaudan SA, Chemin Parfumerie 5, CH-1214 Vernier, Switzerland
关键词
Comprehensive two-dimensional gas; chromatography Dual-detection; Retention time locking; QUADRUPOLE MASS-SPECTROMETRY; FLAME IONIZATION; SPECIATION;
D O I
10.1016/j.chroma.2016.07.052
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this paper, a novel, and easy to perform, retention time locking procedure for locking primary and secondary retention times of detector signals in comprehensive two-dimensional gas chromatography (GCxGC) dual-detection is proposed and its advantages are demonstrated and discussed. The dual detection retention time locking procedure is a 2-step process for a GCxGC system in which the effluent of the primary column is split, by using a pressure regulated splitter, towards the GCxGC modulator using two identical secondary GC columns of which one is installed in the main GC oven and the other is installed in a secondary GC oven. The first step of the locking procedure is to minimize the secondary retention time difference between both detectors of a compound, which has a retention factor (k) close to 0. This is done by stepwise altering the effective secondary column length, simply by sliding the secondary column, which is installed in the main oven, forwards or backwards through the modulator. The second step is to minimize the secondary retention time difference of a compound which has a significant retention in both dimensions. This is done by stepwise altering the secondary oven temperature rate. This locking procedure was successfully demonstrated for the analysis of a diesel sample by GCxGC coupled to a time of flight mass spectrometer (TOFMS) and a nitrogen chemiluminescence detector (NCD) and by GCxGC coupled to a TOFMS and a flame ionization detector (FID). For all compounds the average absolute secondary retention time differences between the NCD or the FID and the TOFMS detectors were 0.03, and 0.07 s, respectively, which are significantly less than the average peak widths at half heights, which was 0.2 s. (c) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:153 / 160
页数:8
相关论文
共 50 条
  • [1] Retention time locking procedure for comprehensive two-dimensional gas chromatography
    Mommers, John
    Knooren, Jeroen
    Mengerink, Ynze
    Wilbers, Arno
    Vreuls, Rene
    van der Wal, Sjoerd
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (21) : 3159 - 3165
  • [2] Retention indices in comprehensive two-dimensional gas chromatography
    von Muehlen, Carin
    Marriott, Philip J.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 401 (08) : 2351 - 2360
  • [3] Retention indices in comprehensive two-dimensional gas chromatography
    Carin von Mühlen
    Philip J. Marriott
    [J]. Analytical and Bioanalytical Chemistry, 2011, 401 : 2351 - 2360
  • [4] Evaluation of a retention model in comprehensive two-dimensional gas chromatography
    Vendeuvre, C
    Bertoncini, F
    Thiébaut, D
    Martin, M
    Hennion, MC
    [J]. JOURNAL OF SEPARATION SCIENCE, 2005, 28 (11) : 1129 - 1136
  • [5] Retention correlation maps in comprehensive two-dimensional gas chromatography
    Western, RJ
    Marriott, PJ
    [J]. JOURNAL OF SEPARATION SCIENCE, 2002, 25 (13) : 832 - 838
  • [6] Simple calibration procedure for comprehensive two-dimensional gas chromatography
    Kallio, Minna
    Hyotylainen, Tuulia
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2008, 1200 (02) : 264 - 267
  • [7] Model for predicting comprehensive two-dimensional gas chromatography retention times
    Seeley, John V.
    Seeley, Stacy K.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1172 (01) : 72 - 83
  • [8] Molecular structure retention relationships in comprehensive two-dimensional gas chromatography
    Marriott, PJ
    Massil, T
    Hügel, H
    [J]. JOURNAL OF SEPARATION SCIENCE, 2004, 27 (15-16) : 1273 - 1284
  • [9] Retention modelling of polychlorinated biphenyls in comprehensive two-dimensional gas chromatography
    D'Archivio, Angelo Antonio
    Incani, Angela
    Ruggieri, Fabrizio
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 399 (02) : 903 - 913
  • [10] Retention modelling of polychlorinated biphenyls in comprehensive two-dimensional gas chromatography
    Angelo Antonio D’Archivio
    Angela Incani
    Fabrizio Ruggieri
    [J]. Analytical and Bioanalytical Chemistry, 2011, 399 : 903 - 913