共 50 条
Thermodynamic-based retention time predictions of endogenous steroids in comprehensive two-dimensional gas chromatography
被引:17
|作者:
Silva, Aline C. A.
[1
]
Ebrahimi-Najafadabi, Heshmatollah
[3
]
McGinitie, Teague M.
[2
]
Casilli, Alessandro
[1
]
Pereira, Henrique M. G.
[1
]
Aquino Neto, Francisco R.
[1
]
Harynuk, James J.
[2
]
机构:
[1] Univ Fed Rio de Janeiro, Inst Quim, Ilha Fundao, BR-21941909 Rio De Janeiro, RJ, Brazil
[2] Univ Alberta, Dept Chem, Edmonton, AB T6G 2G2, Canada
[3] Guilan Univ Med Sci, Sch Pharm, Dept Med Chem, Rasht 4144656839, Iran
基金:
加拿大自然科学与工程研究理事会;
关键词:
Doping control;
Two-dimensional gas chromatography-time-of-flight mass spectrometry;
Thermodynamics;
Retention time prediction;
Endogenous steroids;
SYSTEMATIC TOXICOLOGICAL ANALYSIS;
LIQUID-CHROMATOGRAPHY;
MASS-SPECTROMETRY;
URINE SAMPLES;
DRUGS;
METABOLOMICS;
METABOLITES;
DISCOVERY;
D O I:
10.1007/s00216-015-8627-0
中图分类号:
Q5 [生物化学];
学科分类号:
071010 ;
081704 ;
摘要:
This work evaluates the application of a thermodynamic model to comprehensive two-dimensional gas chromatography (GC x GC) coupled with time-of-flight mass spectrometry for anabolic agent investigation. Doping control deals with hundreds of drugs that are prohibited in sports. Drug discovery in biological matrices is a challenging task that requires powerful tools when one is faced with the rapidly changing designer drug landscape. In this work, a thermodynamic model developed for the prediction of both primary and secondary retention times in GC x GC has been applied to trimethylsilylated hydroxyl (O-TMS)- and methoxime-trimethylsilylated carbonyl (MO-TMS)-derivatized endogenous steroids. This model was previously demonstrated on a pneumatically modulated GC x GC system, and is applied for the first time to a thermally modulated GC x GC system. Preliminary one-dimensional experiments allowed the calculation of thermodynamic parameters (Delta H, Delta S, and Delta C (p) ) which were successfully applied for the prediction of the analytes' interactions with the stationary phases of both the first-dimension column and the second-dimension column. The model was able to predict both first-dimension and second-dimension retention times with high accuracy compared with the GC x GC experimental measurements. Maximum differences of -8.22 s in the first dimension and 0.4 s in the second dimension were encountered for the O-TMS derivatives of 11 beta-hydroxyandrosterone and 11-ketoetiocholanolone, respectively. For the MO-TMS derivatives, the largest discrepancies were from testosterone (9.65 s) for the first-dimension retention times and 11-keto-etiocholanolone (0.4 s) for the second-dimension retention times.
引用
收藏
页码:4091 / 4099
页数:9
相关论文