Reproducibility of retention time and peak area in comprehensive two-dimensional liquid chromatography

被引:8
|
作者
Elsner, Victoria [1 ]
Wulf, Volker [2 ]
Wirtz, Michaela [2 ]
Schmitz, Oliver J. [1 ,3 ]
机构
[1] Berg Univ Wuppertal, Inst Pure & Appl Mass Spectrometry, D-42119 Wuppertal, Germany
[2] BASF Personal Care & Nutr GmbH, D-40589 Dusseldorf, Germany
[3] Univ Duisburg Essen, D-45141 Essen, Germany
关键词
Comprehensive two-dimensional liquid chromatography; LCxLC-MS; Surfactants; HILIC; ALCOHOL ETHOXYLATES; MASS-SPECTROMETRY; SEPARATION; POLYMERS; QUANTIFICATION;
D O I
10.1007/s00216-014-8090-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Comprehensive two-dimensional liquid chromatography is used to separate anionic, nonionic, and amphoteric surfactants by substance class, alkyl chain distribution, and degree of ethoxylation. A nearly orthogonal system with a hydrophilic interaction chromatography (HILIC) phase in the first and a reversed-phase material in the second dimension is applied to generate a separation with maximum peak capacity. The potential of the developed method is demonstrated by the reproducibility of retention time and peak area, which shows standard deviations less than 5 % and the analysis of real samples. An external calibration and the standard addition method were applied to determine unknown concentrations for the alkyl chain homologues of a betaine and for one ethoxylate (EO) homologue of a fatty alcohol ethoxylate in a sample mixture.
引用
收藏
页码:279 / 284
页数:6
相关论文
共 50 条
  • [1] Reproducibility of retention time and peak area in comprehensive two-dimensional liquid chromatography
    Victoria Elsner
    Volker Wulf
    Michaela Wirtz
    Oliver J. Schmitz
    [J]. Analytical and Bioanalytical Chemistry, 2015, 407 : 279 - 284
  • [2] A study of the precision and accuracy of peak quantification in comprehensive two-dimensional liquid chromatography in time
    Thekkudan, Dennis F.
    Rutan, Sarah C.
    Carr, Peter W.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (26) : 4313 - 4327
  • [3] Retention time reproducibility in comprehensive two-dimensional gas chromatography using cryogenic modulation - An intralaboratory study
    Shellie, RA
    Xie, LL
    Marriott, PJ
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2002, 968 (1-2) : 161 - 170
  • [4] Comprehensive two-dimensional liquid chromatography
    Mondello, Luigi
    Dugo, Paola
    Donato, Paola
    Herrero, Miguel
    Montero, Lidia
    Schmitz, Oliver J.
    [J]. NATURE REVIEWS METHODS PRIMERS, 2023, 3 (01):
  • [5] Comprehensive two-dimensional liquid chromatography
    [J]. Nature Reviews Methods Primers, 3 (1):
  • [6] Comprehensive two-dimensional liquid chromatography
    Robert A. Shellie
    Paul R. Haddad
    [J]. Analytical and Bioanalytical Chemistry, 2006, 386 : 405 - 415
  • [7] Comprehensive two-dimensional liquid chromatography
    Luigi Mondello
    Paola Dugo
    Paola Donato
    Miguel Herrero
    Lidia Montero
    Oliver J. Schmitz
    [J]. Nature Reviews Methods Primers, 3
  • [8] Comprehensive two-dimensional liquid chromatography
    Shellie, Robert A.
    Haddad, Paul R.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 386 (03) : 405 - 415
  • [9] Retention time locking procedure for comprehensive two-dimensional gas chromatography
    Mommers, John
    Knooren, Jeroen
    Mengerink, Ynze
    Wilbers, Arno
    Vreuls, Rene
    van der Wal, Sjoerd
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (21) : 3159 - 3165
  • [10] Smart Templates for peak pattern matching with comprehensive two-dimensional liquid chromatography
    Reichenbach, Stephen E.
    Carr, Peter W.
    Stoll, Dwight R.
    Tao, Qingping
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (16) : 3458 - 3466