Comparative evaluation of image quality among different detector configurations using area detector computed tomography

被引:9
|
作者
Miura Y. [1 ,2 ]
Ichikawa K. [3 ]
Fujimura I. [2 ,4 ]
Hara T. [5 ]
Hoshino T. [6 ]
Niwa S. [2 ,5 ]
Funahashi M. [1 ]
机构
[1] Department of Medical Technology, Osaka General Medical Center, Osaka
[2] Graduate School of Medical Science, Kanazawa University, Kanazawa
[3] Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, 920-0942, Ishikawa
[4] Department of Radiological Technology, Rinku General Medical Center, Izumisano
[5] Department of Medical Technology, Nakatsugawa Municipal General Hospital, Nakatsugawa
[6] Department of Radiology, Ishinkai Yao General Hospital, Yao
基金
日本学术振兴会;
关键词
Computed tomography; Detector configurations; Helical scan; Image quality; System performance function; Volume CT dose index;
D O I
10.1007/s12194-017-0437-y
中图分类号
学科分类号
摘要
The 320-detector row computed tomography (CT) system, i.e., the area detector CT (ADCT), can perform helical scanning with detector configurations of 4-, 16-, 32-, 64-, 80-, 100-, and 160-detector rows for routine CT examinations. This phantom study aimed to compare the quality of images obtained using helical scan mode with different detector configurations. The image quality was measured using modulation transfer function (MTF) and noise power spectrum (NPS). The system performance function (SP), based on the pre-whitening theorem, was calculated as MTF2/NPS, and compared between configurations. Five detector configurations, i.e., 0.5 × 16 mm (16 row), 0.5 × 64 mm (64 row), 0.5 × 80 mm (80 row), 0.5 × 100 mm (100 row), and 0.5 × 160 mm (160 row), were compared using a constant volume CT dose index (CTDIvol) of 25 mGy, simulating the scan of an adult abdomen, and with a constant effective mAs value. The MTF was measured using the wire method, and the NPS was measured from images of a 20-cm diameter phantom with uniform content. The SP of 80-row configuration was the best, for the constant CTDIvol, followed by the 64-, 160-, 16-, and 100-row configurations. The decrease in the rate of the 100- and 160-row configurations from the 80-row configuration was approximately 30%. For the constant effective mAs, the SPs of the 100-row and 160-row configurations were significantly lower, compared with the other three detector configurations. The 80- and 64-row configurations were adequate in cases that required dose efficiency rather than scan speed. © 2018, Japanese Society of Radiological Technology and Japan Society of Medical Physics.
引用
收藏
页码:54 / 60
页数:6
相关论文
共 50 条
  • [41] Breast Cancer Detector Using Microwave Tomography Image Technology
    Pack, Jeong-Ki
    Kim, Tae-Hong
    Jeon, Soon-Ik
    Lee, Jong-Moon
    Kim, Ki-Chai
    2010 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY & TECHNICAL EXHIBITION ON EMC RF/MICROWAVE MEASUREMENTS & INSTRUMENTATION, 2010, : 362 - 365
  • [42] Noninvasive plaque imaging using multislice detector spiral computed tomography
    Schroeder, Stephen
    Kopp, Andreas F.
    Burgstahler, Christof
    SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2007, 33 (02): : 203 - 209
  • [43] Lung Cancer Screening Using Clinical Photon-Counting Detector Computed Tomography and Energy-Integrating-Detector Computed Tomography: A Prospective Patient Study
    Inoue, Akitoshi
    Johnson, Tucker F.
    Walkoff, Lara A.
    Levin, David L.
    Hartman, Thomas E.
    Burke, Kristin A.
    Rajendran, Kishore
    Yu, Lifeng
    McCollough, Cynthia H.
    Fletcher, Joel G.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2023, 47 (02) : 229 - 235
  • [44] Evaluation of the IVIscan Detector for Regulatory Dosimetric Quality Control Including Wide Radiation Beam for Computed Tomography and Cone-Beam Computed Tomography in Radiotherapy
    Popotte, C.
    Munier, M.
    Devic, C.
    Guillochon, N.
    Paul, D.
    MEDICAL PHYSICS, 2022, 49 (06) : E630 - E630
  • [45] The dynamics of deglutition during head rotation using dynamic 320-row area detector computed tomography
    Kochi, Kazutaka
    Sei, Hirofumi
    Tanabe, Yuki
    Yasuda, Kazunori
    Kido, Teruhito
    Yamada, Hiroyuki
    Taguchi, Aki
    Hato, Naohito
    LARYNGOSCOPE INVESTIGATIVE OTOLARYNGOLOGY, 2023, 8 (03): : 746 - 753
  • [46] Evaluation of spinal trauma by multi detector computed tomography and magnetic resonance imaging
    Gamal, Gihan Hassan
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2014, 45 (04): : 1209 - 1214
  • [47] Evaluation of late bypass graft patency by multi row detector computed tomography
    Pinto, L
    Souza, A
    Egito, E
    Romano, E
    Abib, MH
    Bosisio, I
    Barbosa, M
    Pavanello, R
    Mattos, L
    Souza, L
    Souza, JE
    Jatene, A
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 422A - 422A
  • [48] Evaluation of Aortic Root and Valve Calcifications by Multi-Detector Computed Tomography
    Rivard, Andrew L.
    Bartel, Thomas
    Bianco, Richard W.
    O'Donnell, Kasia Simura
    Bonatti, Johannes
    Dichtl, Wolfgang
    Cury, Ricardo C.
    Feuchtner, Gudrun M.
    JOURNAL OF HEART VALVE DISEASE, 2009, 18 (06): : 662 - 670
  • [49] Time to Progression of Pancreatic Cancer: Evaluation with Multi-Detector Computed Tomography
    Ahn S.J.
    Choi S.J.
    Kim H.S.
    Journal of Gastrointestinal Cancer, 2017, 48 (2) : 164 - 169
  • [50] Evaluation of Homogeneity on Cone Beam Computed Tomography Imaging with Flat Panel Detector
    Sugino, Noriyuki
    JOURNAL OF HARD TISSUE BIOLOGY, 2009, 18 (02) : 101 - 109