Comparative evaluation of image quality among different detector configurations using area detector computed tomography

被引:9
|
作者
Miura Y. [1 ,2 ]
Ichikawa K. [3 ]
Fujimura I. [2 ,4 ]
Hara T. [5 ]
Hoshino T. [6 ]
Niwa S. [2 ,5 ]
Funahashi M. [1 ]
机构
[1] Department of Medical Technology, Osaka General Medical Center, Osaka
[2] Graduate School of Medical Science, Kanazawa University, Kanazawa
[3] Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, 920-0942, Ishikawa
[4] Department of Radiological Technology, Rinku General Medical Center, Izumisano
[5] Department of Medical Technology, Nakatsugawa Municipal General Hospital, Nakatsugawa
[6] Department of Radiology, Ishinkai Yao General Hospital, Yao
基金
日本学术振兴会;
关键词
Computed tomography; Detector configurations; Helical scan; Image quality; System performance function; Volume CT dose index;
D O I
10.1007/s12194-017-0437-y
中图分类号
学科分类号
摘要
The 320-detector row computed tomography (CT) system, i.e., the area detector CT (ADCT), can perform helical scanning with detector configurations of 4-, 16-, 32-, 64-, 80-, 100-, and 160-detector rows for routine CT examinations. This phantom study aimed to compare the quality of images obtained using helical scan mode with different detector configurations. The image quality was measured using modulation transfer function (MTF) and noise power spectrum (NPS). The system performance function (SP), based on the pre-whitening theorem, was calculated as MTF2/NPS, and compared between configurations. Five detector configurations, i.e., 0.5 × 16 mm (16 row), 0.5 × 64 mm (64 row), 0.5 × 80 mm (80 row), 0.5 × 100 mm (100 row), and 0.5 × 160 mm (160 row), were compared using a constant volume CT dose index (CTDIvol) of 25 mGy, simulating the scan of an adult abdomen, and with a constant effective mAs value. The MTF was measured using the wire method, and the NPS was measured from images of a 20-cm diameter phantom with uniform content. The SP of 80-row configuration was the best, for the constant CTDIvol, followed by the 64-, 160-, 16-, and 100-row configurations. The decrease in the rate of the 100- and 160-row configurations from the 80-row configuration was approximately 30%. For the constant effective mAs, the SPs of the 100-row and 160-row configurations were significantly lower, compared with the other three detector configurations. The 80- and 64-row configurations were adequate in cases that required dose efficiency rather than scan speed. © 2018, Japanese Society of Radiological Technology and Japan Society of Medical Physics.
引用
收藏
页码:54 / 60
页数:6
相关论文
共 50 条
  • [21] Evaluation of image quality at the detector's edge of dedicated breast positron emission tomography
    Satoh, Yoko
    Motosugi, Utaroh
    Imai, Masamichi
    Omiya, Yoshie
    Onishi, Hiroshi
    EJNMMI PHYSICS, 2021, 8 (01)
  • [22] Evaluation of Trabecular Microstructure of Cancellous Bone Using Quarter-Detector Computed Tomography
    Hasegawa, Hiroaki
    Nango, Nobuhito
    Machida, Masafumi
    DIAGNOSTICS, 2023, 13 (07)
  • [23] Comparison of a Large Area CZT Detector to a Spectroscopic CdTe Detector for X-ray Fluorescence Computed 'Tomography
    Vernekohl, Don
    Streicher, Michael
    Ahmad, Moiz
    Xing, Lei
    He, Zhong
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [24] New Approaches to Reduce Radiation While Maintaining Image Quality in Multi-Detector-Computed Tomography
    Ramirez-Giraldo J.C.
    Fuld M.
    Grant K.
    Primak A.N.
    Flohr T.
    Current Radiology Reports, 3 (2)
  • [25] CHARACTERIZATION OF RENAL STONES USING SPECTRAL DETECTOR COMPUTED TOMOGRAPHY
    Hokamp, N. Grosse
    Karapanos, Leonidas
    Salem, Johannes
    Holz, J. A.
    Hesse, A.
    Ritter, M.
    Heidenreich, Axel
    Maintz, David
    Haneder, Stefan
    JOURNAL OF UROLOGY, 2018, 199 (04): : E841 - E841
  • [26] Comparative study between multi-detector computed tomography and echocardiography in evaluation of congenital vascular rings
    Hamisa, Manal
    Elsharawy, Fatma
    Elsherbeny, Wafaa
    Bayoumy, Suzan
    ALEXANDRIA JOURNAL OF MEDICINE, 2018, 54 (04) : 717 - 723
  • [27] Role of multi-detector computed tomography in the evaluation of pancreatic tumors
    Dawoud, Mahmoud Abdelaziz
    Youssef, Mohamed Ahmed
    Elbarbary, Aly Aly
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2014, 45 (02): : 309 - 316
  • [28] Evaluation of coronary disease in transplant by multi-detector computed tomography
    Sigurdsson, G
    Yamani, MH
    Koyama, Y
    Greenberg, N
    Garcia, MJ
    EUROPEAN HEART JOURNAL, 2004, 25 : 370 - 370
  • [29] Comparative Monte Carlo study on the performance of integration-and list-mode detector configurations for carbon ion computed tomography
    Meyer, Sebastian
    Gianoli, Chiara
    Magallanes, Lorena
    Kopp, Benedikt
    Tessonnier, Thomas
    Landry, Guillaume
    Dedes, George
    Voss, Bernd
    Parodi, Katia
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (03): : 1096 - 1112
  • [30] Ex Vivo Donor Lung Evaluation Using Multi-Detector Row Computed Tomography
    Lynch, W. R.
    Alford, S. K.
    Schmidt, A. J.
    Halaweish, A. F.
    Hoffmann, E. A.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (02): : S95 - S96