Performance of the matrix-assisted laser desorption ionization time-of-flight mass spectrometry system for rapid identification of streptococci: a review

被引:0
|
作者
W.-T. Fan
T.-T. Qin
R.-R. Bi
H.-Q. Kang
P. Ma
B. Gu
机构
[1] Medical Technology Institute of Xuzhou Medical University,Department of Laboratory Medicine
[2] Affiliated Hospital of Xuzhou Medical University,undefined
关键词
Streptococcus Pneumoniae; Necrotizing Fasciitis; Identification Accuracy; Clinical Microbiology Laboratory; Streptococcus Agalactiae;
D O I
暂无
中图分类号
学科分类号
摘要
Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been developed as a new type of soft ionization mass spectrometry in recent years. An increasing number of clinical microbiological laboratories consider it as an innovative approach for bacterial identification. This study was undertaken in order to evaluate the use of MALDI-TOF MS for rapid identification of the clinical streptococci. A systematic review was conducted based on a literature search of the Medline and Embase databases. Fixed-effects models based on the P-value and the I-square were used for meta-analysis while considering the possibility of heterogeneity between studies. Statistical analyses were performed by using STATA 11.0. Twenty-seven studies covering 3,540 streptococci were included in our meta-analysis. The MALDI-TOF MS correctly identified the species of 96% (I2 = 92.8, P < 0.1) of the streptococci. The MALDI-TOF MS correctly identified the species of 99% of the Streptococcus pneumoniae (I2 = 85.2%, P < 0.1), 100% of the Streptococcus pyogenes (I2 = 32.8%, P > 0.1), and 100% of Streptococcus agalactiae (I2 = 20.7%, P > 0.2). What’s more, it also had high confidence in other Streptococcus. But the accuracy of bovis needs to be improved. The overall performance of both MALDI-MS systems was different. Notably, the identifying accuracy rate of streptococci by VITEK MS was 98%, compared to 94% by the MALDI biotyper system. Interestingly, when analyzing the incorrect identification of MALDI-TOF MS, 36 out of the 38 strains of Streptococcus mitis/oralis were inaccurately identified as Streptococcus pneumoniae by the MALDI biotyper system. In conclusion, the results of this review indicated that MALDI-TOF MS could be a reliable and rapid method for identification of the streptococci.
引用
下载
收藏
页码:1005 / 1012
页数:7
相关论文
共 50 条
  • [41] Matrix-assisted laser desorption ionization time-of-flight mass spectrometry and database for identification of Legionella species
    He, Ying
    Chang, Tsung C.
    Li, Haijing
    Shi, Gongyi
    Tang, Yi-Wei
    CANADIAN JOURNAL OF MICROBIOLOGY, 2011, 57 (07) : 533 - 538
  • [42] Identification of Nocardia species using matrix-assisted laser desorption/ionization–time-of-flight mass spectrometry
    Shunsuke Segawa
    Motoi Nishimura
    Kazuyuki Sogawa
    Sachio Tsuchida
    Shota Murata
    Masaharu Watanabe
    Kazuyuki Matsushita
    Katsuhiko Kamei
    Fumio Nomura
    Clinical Proteomics, 2015, 12
  • [43] Analysis of chitosan by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry
    Zhao Zhen-Wen
    Xiong Lei
    Wang Zhen-Peng
    Xin Bin
    Hu Wei-Hua
    Xiong Shao-Xiang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 35 (07) : 1025 - 1028
  • [44] Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry in clinical chemistry
    Marvin, LF
    Roberts, MA
    Fay, LB
    CLINICA CHIMICA ACTA, 2003, 337 (1-2) : 11 - 21
  • [45] Quantification of defensins by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry
    Jorgensen, Malene
    Bergkvist, Kim S. G.
    Welinder, Karen G.
    ANALYTICAL BIOCHEMISTRY, 2006, 358 (02) : 295 - 297
  • [46] Analysis of oligosaccharides by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry
    Yuan, XL
    Zou, HF
    Wang, HL
    Ni, JY
    Zhang, YK
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 27 (07) : 786 - 789
  • [47] Characterization of polyisobutylene by matrix-assisted laser Desorption ionization time-of-flight mass spectrometry
    Ji, HN
    Sato, N
    Nakamura, Y
    Wan, YN
    Howell, A
    Thomas, QA
    Storey, RF
    Nonidez, WK
    Mays, JW
    MACROMOLECULES, 2002, 35 (04) : 1196 - 1199
  • [48] Detection of bacteriocins by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry
    Rose, NL
    Sporns, P
    McMullen, LM
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1999, 65 (05) : 2238 - 2242
  • [49] Matrix-assisted laser desorption ionization/time-of-flight mass spectrometry for clinical diagnosis
    Cho, Yi-Tzu
    Su, Hung
    Huang, Tiao-Lai
    Chen, Hung-Chun
    Wu, Wen-Jeng
    Wu, Pei-Chang
    Wu, Deng-Chyang
    Shiea, Jentaie
    CLINICA CHIMICA ACTA, 2013, 415 : 266 - 275