Performance of the matrix-assisted laser desorption ionization time-of-flight mass spectrometry system for rapid identification of streptococci: a review

被引:0
|
作者
W.-T. Fan
T.-T. Qin
R.-R. Bi
H.-Q. Kang
P. Ma
B. Gu
机构
[1] Medical Technology Institute of Xuzhou Medical University,Department of Laboratory Medicine
[2] Affiliated Hospital of Xuzhou Medical University,undefined
关键词
Streptococcus Pneumoniae; Necrotizing Fasciitis; Identification Accuracy; Clinical Microbiology Laboratory; Streptococcus Agalactiae;
D O I
暂无
中图分类号
学科分类号
摘要
Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been developed as a new type of soft ionization mass spectrometry in recent years. An increasing number of clinical microbiological laboratories consider it as an innovative approach for bacterial identification. This study was undertaken in order to evaluate the use of MALDI-TOF MS for rapid identification of the clinical streptococci. A systematic review was conducted based on a literature search of the Medline and Embase databases. Fixed-effects models based on the P-value and the I-square were used for meta-analysis while considering the possibility of heterogeneity between studies. Statistical analyses were performed by using STATA 11.0. Twenty-seven studies covering 3,540 streptococci were included in our meta-analysis. The MALDI-TOF MS correctly identified the species of 96% (I2 = 92.8, P < 0.1) of the streptococci. The MALDI-TOF MS correctly identified the species of 99% of the Streptococcus pneumoniae (I2 = 85.2%, P < 0.1), 100% of the Streptococcus pyogenes (I2 = 32.8%, P > 0.1), and 100% of Streptococcus agalactiae (I2 = 20.7%, P > 0.2). What’s more, it also had high confidence in other Streptococcus. But the accuracy of bovis needs to be improved. The overall performance of both MALDI-MS systems was different. Notably, the identifying accuracy rate of streptococci by VITEK MS was 98%, compared to 94% by the MALDI biotyper system. Interestingly, when analyzing the incorrect identification of MALDI-TOF MS, 36 out of the 38 strains of Streptococcus mitis/oralis were inaccurately identified as Streptococcus pneumoniae by the MALDI biotyper system. In conclusion, the results of this review indicated that MALDI-TOF MS could be a reliable and rapid method for identification of the streptococci.
引用
收藏
页码:1005 / 1012
页数:7
相关论文
共 50 条
  • [31] Rapid characterization of polyalcohols by silylation and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry
    Adeuya, Anthony
    Price, Neil
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (24) : 3977 - 3981
  • [32] Ionization mechanism of oligonucleotides in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry
    Kong, YF
    Zhu, YF
    Zhang, JY
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (01) : 57 - 64
  • [33] Identification of viridans streptococci With Matrix-Assisted Laser Desorption & Ionization Time-of-flight Mass Spectrometry by an In-house Method and a Commercially Available System
    Stingu, Catalina-Suzana
    Eschrich, Klaus
    Thiel, Juliane
    Borgmann, Toralf
    Schaumann, Reiner
    Rodloff, Arne C.
    ANNALS OF LABORATORY MEDICINE, 2017, 37 (05) : 434 - 437
  • [34] Performance of a Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry Testing Algorithm for the Rapid Identification of Clinical Filamentous Molds
    Fissel, John A.
    Holdren-Serrell, Carrie K.
    Memon, Warda
    Zhang, Sean X.
    FRONTIERS IN CELLULAR AND INFECTION MICROBIOLOGY, 2022, 12
  • [36] Evaluation of Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry in Identification of Nontuberculous Mycobacteria
    Marekovic, Ivana
    Bosnjak, Zrinka
    Jakopovic, Marko
    Boras, Zagorka
    Jankovic, Mateja
    Popovic-Grle, Sanja
    CHEMOTHERAPY, 2015, 61 (04) : 167 - 170
  • [37] Matrix-assisted laser desorption-ionization time-of-flight mass spectrometry for the identification of Neisseria gonorrhoeae
    Buchanan, R.
    Ball, D.
    Dolphin, H.
    Dave, J.
    CLINICAL MICROBIOLOGY AND INFECTION, 2016, 22 (09) : 815.e5 - 815.e7
  • [38] Limitations of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry for the identification of Aspergillus species
    Shao, Jin
    Wang, Qiqi
    Wei, Linwei
    Wan, Zhe
    Li, Ruoyu
    Yu, Jin
    MEDICAL MYCOLOGY, 2022, 60 (02)
  • [39] Identification of the 'Streptococcus anginosus group' by matrix-assisted laser desorption ionization - time-of-flight mass spectrometry
    Woods, Katherine
    Beighton, David
    Klein, John L.
    JOURNAL OF MEDICAL MICROBIOLOGY, 2014, 63 : 1143 - 1147
  • [40] Identification of Leishmania at the species level with matrix-assisted laser desorption ionization time-of-flight mass spectrometry
    Cassagne, C.
    Pratlong, F.
    Jeddi, F.
    Benikhlef, R.
    Aoun, K.
    Normand, A. -C.
    Faraut, F.
    Bastien, P.
    Piarroux, R.
    CLINICAL MICROBIOLOGY AND INFECTION, 2014, 20 (06) : 551 - 557