Evaluation of a Passive Air Sampler for Measuring Indoor Formaldehyde

被引:0
|
作者
Sun-Tae Kim
Bongbeen Yim
Jaeho Jeong
机构
[1] Daejeon University,Department of Environmental Engineering, College of Engineering
[2] R & D Center,undefined
[3] Envors Co.,undefined
[4] Ltd.,undefined
来源
Analytical Sciences | 2007年 / 23卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A passive air sampler, using 4-amino-3-hydrazino-5-mercapto-1,2,4-triazole, was evaluated for the determination of formaldehyde in indoor environments. Chromatography paper cleaned using a 3% hydrogen peroxide solution was experimentally determined as being the optimum absorption filter for the collection of formaldehyde (0.05 μg cm-2 formaldehyde). From a linear-regression analysis between the mass of formaldehyde time-collected on a passive air sampler and the formaldehyde concentration measured by an active sampler, the sampling rate of the passive air sampler was 1.52 L h-1. The sampling rate, determined for the passive air sampler in relation to the temperature (19–28°C) and the relative humidity (30–90%), were 1.56 ± 0.04 and 1.58 ± 0.07 L h-1, respectively. The relationship between the sampling rate and the air velocity was a linear-regression within the observed range. In the case of exposed samplers, the stability of the collected formaldehyde decreased with increasing storage time (decrease of ca. 25% after 22 days); but with the unexposed samplers the stability of the blank remained relatively unchanged for 7 days (decrease of ca. 37% after 22 days). The detection limits for the passive air sampler with an exposure time of 1 day and 7 days were 10.4 and 1.48 μg m-3, respectively.
引用
收藏
页码:497 / 500
页数:3
相关论文
共 50 条
  • [21] Evaluation of Formaldehyde Guideline Values for Indoor Air
    Salthammer, Tunga
    EPIDEMIOLOGY, 2011, 22 (01) : S39 - S39
  • [22] Badge-type Diffusive Sampler Using 3-Methyl-2-benzothiazolinone Hydrazone for Measuring Formaldehyde in Indoor Air
    Bongbeen Yim
    Euisuk Jung
    Analytical Sciences, 2006, 22 : 993 - 997
  • [23] Badge-type diffusive sampler using 3-methyl-2-benzothiazolinone hydrazone for measuring formaldehyde in indoor air
    Yim, Bongbeen
    Jung, Euisuk
    ANALYTICAL SCIENCES, 2006, 22 (07) : 993 - 997
  • [24] Development of a passive sampler for long-term measurements of formaldehyde and total oxidants in air
    Bertoni, G
    Ciuchini, C
    Di Palo, V
    Possanzini, M
    CHROMATOGRAPHIA, 2005, 61 (7-8) : 385 - 389
  • [25] Development of a Passive Sampler for Long-Term Measurements of Formaldehyde and Total Oxidants in Air
    G. Bertoni
    C. Ciuchini
    V. Di. Palo
    M. Possanzini
    Chromatographia, 2005, 61 : 385 - 389
  • [26] Removal of formaldehyde from indoor air by passive type air-cleaning materials
    Sekine, Y
    Nishimura, A
    ATMOSPHERIC ENVIRONMENT, 2001, 35 (11) : 2001 - 2007
  • [27] FORMALDEHYDE IN INDOOR AIR
    SCHWEINSBERG, F
    ZENTRALBLATT FUR BAKTERIOLOGIE MIKROBIOLOGIE UND HYGIENE SERIE B-UMWELTHYGIENE KRANKENHAUSHYGIENE ARBEITSHYGIENE PRAVENTIVE MEDIZIN, 1987, 183 (5-6): : 481 - 482
  • [28] Global evaluation and calibration of a passive air sampler for gaseous mercury
    McLagan, David S.
    Mitchell, Carl P. J.
    Steffen, Alexandra
    Hung, Hayley
    Shin, Cecilia
    Stupple, Geoff W.
    Olson, Mark L.
    Luke, Winston T.
    Kelley, Paul
    Howard, Dean
    Edwards, Grant C.
    Nelson, Peter F.
    Xiao, Hang
    Sheu, Guey-Rong
    Dreyer, Annekatrin
    Huang, Haiyong
    Hussain, Batual Abdul
    Lei, Ying D.
    Tavshunsky, Ilana
    Wania, Frank
    ATMOSPHERIC CHEMISTRY AND PHYSICS, 2018, 18 (08) : 5905 - 5919
  • [29] EVALUATION OF A DIFFUSIVE SAMPLER FOR FORMALDEHYDE
    ELLWOOD, PA
    GROVES, JA
    PENGELLY, MI
    ANNALS OF OCCUPATIONAL HYGIENE, 1990, 34 (03): : 305 - 313
  • [30] A Prototype Passive Air Sampler for Measuring Dry Deposition of Polycyclic Aromatic Hydrocarbons
    Eng, Anita
    Harner, Tom
    Pozo, Karla
    ENVIRONMENTAL SCIENCE & TECHNOLOGY LETTERS, 2014, 1 (01): : 77 - 81