EVALUATION OF A DIFFUSIVE SAMPLER FOR FORMALDEHYDE

被引:4
|
作者
ELLWOOD, PA
GROVES, JA
PENGELLY, MI
机构
[1] Health and Safety Executive
来源
ANNALS OF OCCUPATIONAL HYGIENE | 1990年 / 34卷 / 03期
关键词
Air Pollution - Indoor - Formaldehyde - Sampling - Sampling - Instruments;
D O I
10.1093/annhyg/34.3.305
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
A diffusive sampling system, using a commercially available liquid sorbent badge, has been evaluated for the determination of airborne formaldehyde concentrations according to the U.K. Health and Safety Executive protocol. The results of laboratory and field experiments are presented. The results obtained using the diffusive sampler during field measurements were about 10% higher overall than those obtained using a conventional pumped sampler. © 1990 British Occupational Hygiene Society.
引用
收藏
页码:305 / 313
页数:9
相关论文
共 50 条
  • [1] DETERMINATION OF FORMALDEHYDE IN TEXTILES USING A DIFFUSIVE SAMPLER
    NARUSE, M
    NARUSE, H
    AOYAMA, M
    BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 1995, 55 (06) : 810 - 816
  • [2] Evaluation of badge-type diffusive sampler performance for measuring indoor formaldehyde
    Yim, Bongbeen
    Lee, Kyusung
    Kim, Jooin
    Hong, Hyunsu
    Kim, Suntae
    Environmental Engineering Research, 2013, 18 (03) : 123 - 128
  • [3] A DIFFUSIVE SAMPLER EVALUATION PROTOCOL
    BROWN, RH
    HARVEY, RP
    PURNELL, CJ
    SAUNDERS, KJ
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1984, 45 (02): : 67 - 75
  • [4] EVALUATION OF A PASSIVE SAMPLER FOR AIRBORNE FORMALDEHYDE
    BINDING, N
    WITTING, U
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1991, 339 (04): : 218 - 222
  • [5] EVALUATION OF A DIFFUSIVE SAMPLER FOR AIR SAMPLING OF MONOTERPENES
    ERIKSSON, K
    LEVIN, JO
    RHEN, M
    LINDAHL, R
    ANALYST, 1994, 119 (01) : 85 - 88
  • [6] MONITORING OF PARTS-PER-BILLION LEVELS OF FORMALDEHYDE USING A DIFFUSIVE SAMPLER
    LEVIN, JO
    LINDAHL, R
    ANDERSSON, K
    JAPCA-THE JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1989, 39 (01): : 44 - 47
  • [7] Evaluation of a diffusive sampler for measurement of carbonyl compounds in air
    Uchiyama, S
    Aoyagi, S
    Ando, M
    ATMOSPHERIC ENVIRONMENT, 2004, 38 (37) : 6319 - 6326
  • [8] Experience in the use of the NIOSH diffusive sampler evaluation protocol
    Harper, M
    Guild, LV
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1996, 57 (12): : 1115 - 1123
  • [9] Performance of the Radiello® diffusive sampler for formaldehyde measurement: the influence of exposure conditions and ozone interference
    Vignau-Laulhere, Jane
    Plaisance, Herve
    Mocho, Pierre
    Raulin, Katarzyna
    Bigay, Yves
    Desauziers, Valerie
    ANALYTICAL METHODS, 2015, 7 (13) : 5497 - 5503
  • [10] Evaluation of a passive air sampler for measuring indoor formaldehyde
    Kim, Sun-Tae
    Yim, Bongbeen
    Jeong, Jaeho
    ANALYTICAL SCIENCES, 2007, 23 (04) : 497 - 500