Evaluation of a Passive Air Sampler for Measuring Indoor Formaldehyde

被引:0
|
作者
Sun-Tae Kim
Bongbeen Yim
Jaeho Jeong
机构
[1] Daejeon University,Department of Environmental Engineering, College of Engineering
[2] R & D Center,undefined
[3] Envors Co.,undefined
[4] Ltd.,undefined
来源
Analytical Sciences | 2007年 / 23卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A passive air sampler, using 4-amino-3-hydrazino-5-mercapto-1,2,4-triazole, was evaluated for the determination of formaldehyde in indoor environments. Chromatography paper cleaned using a 3% hydrogen peroxide solution was experimentally determined as being the optimum absorption filter for the collection of formaldehyde (0.05 μg cm-2 formaldehyde). From a linear-regression analysis between the mass of formaldehyde time-collected on a passive air sampler and the formaldehyde concentration measured by an active sampler, the sampling rate of the passive air sampler was 1.52 L h-1. The sampling rate, determined for the passive air sampler in relation to the temperature (19–28°C) and the relative humidity (30–90%), were 1.56 ± 0.04 and 1.58 ± 0.07 L h-1, respectively. The relationship between the sampling rate and the air velocity was a linear-regression within the observed range. In the case of exposed samplers, the stability of the collected formaldehyde decreased with increasing storage time (decrease of ca. 25% after 22 days); but with the unexposed samplers the stability of the blank remained relatively unchanged for 7 days (decrease of ca. 37% after 22 days). The detection limits for the passive air sampler with an exposure time of 1 day and 7 days were 10.4 and 1.48 μg m-3, respectively.
引用
收藏
页码:497 / 500
页数:3
相关论文
共 50 条
  • [1] Evaluation of a passive air sampler for measuring indoor formaldehyde
    Kim, Sun-Tae
    Yim, Bongbeen
    Jeong, Jaeho
    ANALYTICAL SCIENCES, 2007, 23 (04) : 497 - 500
  • [2] Field evaluation of the Analyst® passive sampler for the determination of formaldehyde and acetaldehyde in indoor and outdoor ambient air
    Villanueva, Florentina
    Colmenar, Inmaculada
    Mabilia, Rosanna
    Scipioni, Chiara
    Cabanas, Beatriz
    ANALYTICAL METHODS, 2013, 5 (02) : 516 - 524
  • [3] Measurement of indoor formaldehyde concentrations with a passive sampler
    Gillett, RW
    Kreibich, H
    Ayers, GP
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (10) : 2051 - 2056
  • [4] NEW ANALYST® PASSIVE SAMPLER FOR THE MONITORING OF FORMALDEHYDE IN INDOOR AND OUTDOOR AMBIENT AIR
    Mabilia, Rosanna
    Scipioni, Chiara
    Villanueva Garcia, Florentina
    FRESENIUS ENVIRONMENTAL BULLETIN, 2010, 19 (9B): : 2047 - 2055
  • [5] Evaluation of passive sampler for measurement of glutaraldehyde in occupational indoor air
    Sekine, Y
    Oikawa, D
    Saitoh, K
    Asano, Y
    JOURNAL OF HEALTH SCIENCE, 2005, 51 (06) : 629 - 635
  • [6] Development of high sensitivity measurement method for formaldehyde in indoor air - Development of passive sampler
    Matsunobu, T
    Matsumura, T
    Miyaji, M
    Isozaki, A
    Watanabe, F
    Toyama, I
    Yamagata, F
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 2823 - 2827
  • [7] EVALUATION OF A PASSIVE SAMPLER FOR AIRBORNE FORMALDEHYDE
    BINDING, N
    WITTING, U
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1991, 339 (04): : 218 - 222
  • [8] Evaluation of badge-type diffusive sampler performance for measuring indoor formaldehyde
    Yim, Bongbeen
    Lee, Kyusung
    Kim, Jooin
    Hong, Hyunsu
    Kim, Suntae
    Environmental Engineering Research, 2013, 18 (03) : 123 - 128
  • [9] LABORATORY EVALUATION OF A NOVEL REACTIVE PASSIVE SAMPLER FOR THE QUANTITATIVE-DETERMINATION OF FORMALDEHYDE IN AIR
    DILLON, HK
    GAO, PF
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1994, 55 (11): : 1061 - 1068
  • [10] INDOOR AIR-POLLUTION BY FORMALDEHYDE - EVALUATION AND MEASURING INSTITUTES IN BAVARIA
    BAUMEISTER, W
    MUCKE, W
    MUNCHENER MEDIZINISCHE WOCHENSCHRIFT, 1988, 130 (10): : 179 - 182