Measurement of indoor formaldehyde concentrations with a passive sampler

被引:51
|
作者
Gillett, RW [1 ]
Kreibich, H
Ayers, GP
机构
[1] CSIRO, Aspendale, Vic 3195, Australia
[2] Tech Univ Berlin, Berlin, Germany
关键词
D O I
10.1021/es990929n
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
An existing Ferm type passive sampler technique has been further developed to measure concentrations of formaldehyde gas in indoor air. Formaldehyde forms a derivative after reaction with a filter coated with 2,4-dinitrophenylhydrazine (2,4-DNPH). The formaldehyde 2,4-dinitrophenylhydrazine derivative (formaldehyde-2,4-DNPH) is extracted from the filter, and the concentration is determined by high performance liquid chromatography. The technique has been Validated against an active sampling method, and the agreement is close when the appropriate laminar boundary layer depth is applied to the passive measurement. For this technique an exposure period of 3 days is equivalent to a limit of detection of formaldehyde of 3.4 ppbv and a limit of quantification of 7.6 ppbv. To test the performance of the passive samplers ambient formaldehyde measurements were carried out inside homes and in a range of workplace environments.
引用
下载
收藏
页码:2051 / 2056
页数:6
相关论文
共 50 条
  • [1] Evaluation of a passive air sampler for measuring indoor formaldehyde
    Kim, Sun-Tae
    Yim, Bongbeen
    Jeong, Jaeho
    ANALYTICAL SCIENCES, 2007, 23 (04) : 497 - 500
  • [2] Evaluation of a Passive Air Sampler for Measuring Indoor Formaldehyde
    Sun-Tae Kim
    Bongbeen Yim
    Jaeho Jeong
    Analytical Sciences, 2007, 23 : 497 - 500
  • [3] Development of high sensitivity measurement method for formaldehyde in indoor air - Development of passive sampler
    Matsunobu, T
    Matsumura, T
    Miyaji, M
    Isozaki, A
    Watanabe, F
    Toyama, I
    Yamagata, F
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 2823 - 2827
  • [4] Passive flux sampler for measurement of formaldehyde emission rates
    Shinohara, Naohide
    Fujii, Minoru
    Yamasaki, Akihiro
    Yanagisawa, Yukio
    ATMOSPHERIC ENVIRONMENT, 2007, 41 (19) : 4018 - 4028
  • [5] Screening of formaldehyde indoor sources and quantification of their emission using a passive sampler
    Blondel, Alodie
    Plaisance, Herve
    BUILDING AND ENVIRONMENT, 2011, 46 (06) : 1284 - 1291
  • [6] MEASUREMENT OF NO2 INDOOR AND OUTDOOR CONCENTRATIONS IN SELECTED PUBLIC SCHOOLS OF LAHORE USING PASSIVE SAMPLER
    Mehmood, T.
    Ali, Z.
    Noor, N.
    Sidra, S.
    Nasir, Z. A.
    Colbeck, I.
    JOURNAL OF ANIMAL AND PLANT SCIENCES, 2015, 25 (03): : 681 - 686
  • [7] A PASSIVE SAMPLER FOR AIRBORNE FORMALDEHYDE
    GROSJEAN, D
    WILLIAMS, EL
    ATMOSPHERIC ENVIRONMENT PART A-GENERAL TOPICS, 1992, 26 (16): : 2923 - 2928
  • [8] A passive sampler for airborne formaldehyde
    Grosjean, D.
    Williams II, E.L.
    Atmospheric Environment - Part A General Topics, 1992, 26 A (16): : 2923 - 2928
  • [9] NEW ANALYST® PASSIVE SAMPLER FOR THE MONITORING OF FORMALDEHYDE IN INDOOR AND OUTDOOR AMBIENT AIR
    Mabilia, Rosanna
    Scipioni, Chiara
    Villanueva Garcia, Florentina
    FRESENIUS ENVIRONMENTAL BULLETIN, 2010, 19 (9B): : 2047 - 2055
  • [10] Evaluation of passive sampler for measurement of glutaraldehyde in occupational indoor air
    Sekine, Y
    Oikawa, D
    Saitoh, K
    Asano, Y
    JOURNAL OF HEALTH SCIENCE, 2005, 51 (06) : 629 - 635